1) common wiper
共用接帚,共用弧刷
2) shared grounding
共用接地
1.
With the increasing of the diversification and quantity of load equipments in low-voltage electric power supply distribution system, it becomes a question as whether an electric equipment should be independent grounding or shared grounding.
随着低压供配电系统中的负荷设备种类的多样化和数量的日益增长,各种电气设备的接地是分开独立接地,还是共用接地,已成为广大设计工作者十分关心的问题。
3) common ground electrode
共用接地极
1.
Analysis on excavation support work of one common ground electrode engineering;
某共用接地极工程基坑支护实例分析
2.
Fulong converter station of Xiangjiaba-Shanghai ±800 kV UHV DC line has a common ground electrode shared by 3 stations,which has its own design and technical challenges compared to regular independent ground electrodes.
向家坝—上海±800kV特高压直流复龙换流站接地极按三站共用接地极设计,共用接地极相比常规独立接地极有其设计特点和技术难点。
3.
Firstly, the types and characteristics of the common ground electrode used in HVDC system are analyzed in this paper.
为分析共用接地极后两直流系统受端换流站中性母线电位升的变化情况,进而研究共用接地极对直流系统稳态运行的影响,首先讨论了直流输电系统共用接地极的型式和共用接地极的特点,建立了两回直流系统共用接地极的数学模型,并结合云广特高压直流输电与贵广II回直流输电系统参数,研究分析不同运行方式下该两回直流输电系统共用接地极对直流系统运行影响大小,以及与独立接地极相比共用接地极不同运行方式对环境的影响大小,最后对共用接地极对环境的影响以及公用接地极对直流系统运行的影响方面的问题提出了解决措施。
4) common grounding electrode
共用接地极
1.
Analysis on the common grounding electrode mode for UHVDC and HVDC power transmission systems;
特高压和高压直流输电系统共用接地极模式分析
2.
Several studies already done show that common grounding electrode would not influence the operation performances of two HVDC transmission.
为了不对系统运行产生太大影响并节省工程用地和建造费用,云广特高压直流输电工程和贵广Ⅱ回高压直流输电工程广东侧考虑采用共用接地极模式建造。
3.
For several fault types of common grounding electrode in HVDC system,the frequency spectrum analysis of transient process of earthing current is performed and the features that the frequency spectrum of transient process of earthing current of common grounding electrode is within the range from 0 to 200 Hz is obtained.
针对直流输电系统共用接地极的几种故障类型,对入地电流的暂态过程进行频谱分析,总结出共用接地极入地电流暂态过程频谱低于200Hz的特点。
5) common earth electrode
共用接地极
1.
Main design fundamentals for common earth electrodes in HVDC;
高压直流输电共用接地极主要设计原则
2.
Aiming at the difficulties in site selection of earth electrode as well as technical and economic comparisons of individual earth electrode,a common earth electrode by three converter stations design for the Jinsha River Phase I outgoing ±800 kV UHVDC project is presented.
针对接地极极址选择困难和基于与独立接地极的技术经济比较结果,提出了金沙江一期±800 kV特高压直流外送工程三换流站共用接地极的设计方案。
6) sharing earth electrode
共用接地极
1.
Using the concrete parameters of UHVDC transmission project from Xiangjiaba to Nanhui and by use of electromagnetic transient calculation software EMTP-RV,the detailed simulation research on the scheme of sharing earth electrode by three UHVDC transmission systems at sending end is conducted.
根据向家坝—南汇±800 kV直流输电工程的具体参数,利用电磁暂态仿真软件EMTP-RV对3个特高压直流输电系统送端采用共用接地极方案进行了详细的仿真研究;通过模拟直流系统不同运行方式下几种直流侧故障的暂态过程,深入分析了共用接地极方案对直流系统内过电压的影响。
2.
Sharing earth electrode by three UHVDC system rectifiers or inverters are studied respectively by electromagnetic transient analysis software EMTP-RV based on the main parameters of±800kV HVDC project from Xiangjiaba to Nanhui.
结合金沙江一期送出±800kV直流输电工程前期可行性研究结果,本文分析了多个直流系统共用接地极的接线方式,以及三个特高压直流系统共用接地极的各种运行方式。
补充资料:电力系统中性点接地变压器接地
电力系统中性点接地变压器接地
earthing transformer for neutral grounding
d旧n]一x .tong之hongx旧gd一onj旧d一b旧nyoq一j旧d-电力系统中性点接地变压器接地(earthingtransformer for neutral grounding)电力系统中利用接地变压器获得中性点与大地连接,也称中性点辅助变压器接地。当系统中的变压器不具备接人电阻器或接地故障消除器的条件(例如变压器三相绕组为△接线或虽为Y接线但容量不符合要求)时,要利用辅助的变压器提供一个用于接地的中性点。这种变压器应具备零序阻抗低、激磁阻抗大、功率损耗小的特性。绕组为曲折(Z)接线的变压器符合要求,如图1(a)所示。它可以带二次侧绕组,也可以只有一次侧绕组。 这种变压器每相由匝数相等的两个串联分绕组组成,每个磁芯上的两个分绕组间以及它们对二次侧绕组的零序互磁为零。很明显,这种变压器的零序电抗XTo只为变压器一次侧绕组的漏电抗Xs,,即XTo-Xs;,而系统中性点与地之间的计算阻抗Z。为Z。一25,+Z。,其中Z。为中性点电阻器或电抗器的阻抗。见图1(b)。2.为激磁阻抗。见图2,YN,d接线的变压器二次侧绕组可以带一定负荷。从过负荷能力考虑已经知道.接YN,d接线的双绕组变压器中性点的接地设备的容t不应超过变压器额定容t的50%.由此可认为,当变压器额定容t按中性点接地设备的容t设计时,允许二次侧绕组带50%额定容t的负荷. 还有一种特殊接线的接地变压器和接地设备的组合,是1918年鲍赫(R.Bauch)发明的,故也称饱鹅变压器,见图3。变压器一次侧中性点直接接地,开口三角形接线的二次侧连接接地设备,这与一次侧中性点接有接地设备是等效的。单相接地时,不对称的电压可分解为对称的正序和零序,磁通也可分解为对应的分量。磁通人m、人。、人.需要极小的激磁电流,并对应于正序电压U.。、U、。、U。。,零序电压UO.对各相是一样的,故三个磁柱中有相同的磁通式,对零序磁通来说,变压器相当一个单相变压器,只不过分裂为3个磁柱和3个绕组,见图3(c)。单相接地时,这种变压器每个分绕组上的电压为少尹z‘一.哟.!|||一下咖l!补丰气l一!{屯犷!{屯享!孟=zl息)一刃川l|拍--l--﹄·图1绕组为曲折(Z)接线的变压器 (a)接线图.(b)零序阻抗图会‘价“相“压,·““”的““是中”点接地“备电流的1/3,即夸。因而变压器的额定功率为3x2‘会‘争即中性点接地设备“率”1.15倍。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条