2) fire alarm
火灾报警
1.
A novel intelligent distributed fire alarming control system;
一种新型智能分布式火灾报警控制系统
2.
The Applications to the Distributed Fiber Temperature Measurement for Fire Alarm System;
光纤分布式温度检测在火灾报警系统中的应用
3.
Application of object-oriented technology to fire alarm control programming;
面向对象技术在火灾报警控制软件设计中的应用研究
3) fire alarming
火灾报警
1.
This paper introduces the principle of the olfactory analogy,and advances a method for designing the fire alarming system of intelligent building by using neural network and fuzzy system theory.
介绍了人工嗅觉模拟技术的原理,提出了一种利用神经网络和模糊系统理论设计智能建筑火灾报警系统的方法。
2.
Aiming at the pressing demand for fire alarming systems in the present market,according to the principle and application of optical fiber grating temperature sensor,the paper puts forward a new optical fiber grating fire alarming technology sensitive to temperature.
针对目前市场上对火灾报警系统装置的需求,依据光纤光栅温度传感器的原理和应用,提出了一种新的光纤光栅感温火灾报警系统,它具有高精确度、高可靠性、不受电磁干扰等优点。
3.
A key part of the building security is a fire alarming and monitoring system which involves with management of sensors,establishing of real-time relations,live display of 2D alarming views,data communications,data records and so on.
火灾报警监控图形系统是楼宇安全保障系统的重要组成部分,它涉及到报警探测器、控制器的组织与管理,联动关系的建立,报警平面图的动态显示,以及数据通讯和记录等。
4) fire alarm system
火灾报警
1.
Design and Application of Fire Alarm System in Subway;
地铁火灾报警系统的设计与应用
2.
The results show that the new fire alarm system can be used to alarm fire exactly and duly.
分析了特殊行业对火灾报警的要求,介绍了光纤光栅感温技术原理、隧道火灾点火实验以及技术应用的情况。
3.
The main reason applied improperly for highway tunnel fire alarm system is to be not known well for the equivement performance.
针对目前常用的三种火灾自动报警设备,通过在实体隧道做试验,得到了风速、烟雾、火灾报警分区数量等因素对火灾报警时间的影响,提出公路隧道火灾自动报警设施的试验方法与设备选型应考虑的主要因素。
5) fire warning
火灾报警
1.
This paper probes into some problems often met in electrical and fi re design, including the design of secondary lines of fire fans and fire pumps, th e functional differences and arrangements of hand fire warning button and fire h ydrant button, the installation of fire urgent broadcasting and fire warning equ ipment, etc.
探讨了电气消防设计中经常遇到的几个问题,包括消防风机、消防水泵等二次线路的设计,手动火灾报警按钮与消火栓按钮的功能区别及设置,火灾应急广播与火灾警报装置的设置等。
2.
Fire warning system based on mobile platform realizes the group sends of fire warning messages which are send to the concerned personnel in enterprises,and brings the convenience of taking the fire protection mea-sures in time.
基于移动平台的火灾短信报警系统实现了火灾报警短信的群发,保证准确、及时的把火灾信息发送给企业的有关人员,便于相关部门及时采取消防措施。
6) fire alarm
火灾报警器
1.
By using the remote control system of fire alarm systems which is manufactured by others could realize.
针对传统火灾报警器没有统一通信协议标准、无法相互兼容等问题,设计一种基于 Internet 的新型监控系统,并给出该系统的组成、设计及实现方法;通过该系统可实现对不同厂 家的火灾报警器的远程监控。
补充资料:火灾报警系统
火灾报警系统
fire alarm system
huozo一booJ旧9 xitong火灾报警系统(fire alarm systern)探测火灾征兆并迅速报警的设施。通常由传感器、信号发生器、中继器和信号接收器等组成。当室内温度上升或有烟气存在等火灾征兆时,传感器将信号传送给信号接收器,从而发出声响和光照报警。信号发生器也可由人工操作,当发现火灾征兆时,按动电钮,信号传送至信号接收器。接收后启动信号灯和厂区信号灯,发出报警声响,还可直接通话报警。根据需要在传感器和信号接收器之间设置中继器,以便传递信号。 在火灾报警系统中,传感器是关键元件,要求迅速无误地摄取异常现象。常用的有测温、测烟和放射线传感器等。 测温传感器分为定温式传感器、差动式传感器和补偿式传感器。定温式传感器一般用热塑性塑料覆盖易熔金属丝组成,当室内达到一定温度时.塑料和易熔金属丝软化熔断,信号发出。测温传感器的动作温度,各国规定都不相同:日本为60一15oC,美国为52一255C,英国112.SC。差动式传感器是利用温度的上升率超过某限值时而动作的传感器。此限值一般为5一4OK/mm,而多数为10~15K/min。补偿式传感器是把定温式传感器的敏感元件和差动式传感器的敏感元件组合为一体构成。 测烟传感器是利用燃烧后产生浮游粒子影响光线通过的原理制作的。 放射险传感器是利用摄取火焰中发出的红外线、可见光线和紫外线等放射线而动作的 除上述火灾报警系统外,还有漏电火灾报警器、气体泄漏检测器、石油管道泄漏检测器等。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条