2) hybrid actuator
复合作动器
1.
With the analysis of the current Hexapod s actuators,a high precision dual-driving hybrid actuator was developed.
针对基于并联机构的空间精密跟瞄Hexapod平台的大行程、高性能要求,通过对现有主动元件的分析,从作动器角度研制了以滚珠丝杠作动器为宏动部分、压电作动器为微动部分的大行程高频响精密复合作动器,测试了复合作动器的行程、开环定位精度及动态特性,以dSPACE半物理仿真系统为核心建立了实验系统,进行了复合作动器单自由度精确定位实验和振动主动控制实验。
2.
With the dual-driving hybrid actuators developed by us,a Hexapod\'s optimal configuration is designed,its joints are manufactured and a high stabilization precision point-tracking Hexapod prototype is assembled.
为了实现星载光学设备的精密跟瞄,以自行研制的宏/微双重驱动复合作动器为主动元件,设计了合理的平台构型,选择并装配了铰链等关键部件,组装完成了具有振动主动控制和大幅跟瞄能力的Hexa-pod平台原理样机。
3) Compound action potential
复合动作电位
1.
The effects of muscarinic and nicotinic receptor antagonists on compound action potentials in the cochleae of gerbils;
毒蕈碱和烟碱受体阻断剂对沙鼠耳蜗复合动作电位的影响
2.
The compound action potential (CAP) was recorded and pathologic changes were evaluated with light .
方法 :经耳蜗鼓阶灌注高浓度谷氨酸 (Glu H ,2 0mmol/L ,1 0 μl)、低浓度谷氨酸 (Glu L ,1 0mmol/L ,1 0 μl)后检测不同时点复合动作电位 (CAP)反应阈 ,并观察耳蜗显微和超微结构变化。
3.
The stimulus threshold,maximal stimulus,peak value of compound action potential and refractory period were measured on the toad sciatic nerves after 30 seconds while adding ethanol or acetaldehyde of different concentration with Ringer solution.
将含有不同浓度的乙醇、乙醛的任氏液滴加到蟾蜍坐骨神经表面,30 s后测定神经干刺激阈值、最大刺激值、复合动作电位峰值和不应期等电生理指标。
4) repetitive compound muscle action potential
重复复合肌肉动作电位
1.
Aim:To observe the electrophysiological characteristics of repetitive compound muscle action potential(R-CMAP)in congenital myasthenic syndrome patients and discuss the significance in diagnosis.
目的:观察先天性肌无力综合征(CMS)患者重复复合肌肉动作电位(R-CMAP)的特征,讨论其诊断意义。
5) Compound motor action potential
复合运动动作电位
6) compound muscle action potential
复合肌肉动作电位
1.
Establishment of the normative ranges for nerve conduction values of distal compound muscle action potential;
正常成人神经传导远端复合肌肉动作电位参数值正常范围的建立
2.
Aim:To evaluate the characteristics of amplitude,area and duration of compound muscle action potential (CMAP) as well as conduction block in different ulnar segments in GuiUain-Barr(?)syndrome(GBS) and chronic inflammatory demyelinating perineuropathy(CIDP) by segmental and short-segmental stimulation.
目的:探讨节段和短段刺激尺神经后不同节段复合肌肉动作电位(CMAP)负波各参数变化及传导阻滞在吉兰-巴雷综合征(GBS)和慢性炎性脱髓鞘性周围神经病(CIDP)中的意义。
补充资料:差动变压器式压力传感器
由弹性敏感元件和差动变压器构成的压力传感器。它的弹性敏感元件作为受力机构,把被测压力转换成位移,再用差动变压器把位移转换为与被测压力成一定关系的电信号。差动变压器属于电感式传感器,所以差动变压器式压力传感器又称电感式压力传感器。利用弹性敏感元件的不同形式可制成多种用途的差动变压器式压力传感器。图a中是3种差动变压器式压力传感器的结构示意图。图a中的弹性敏感元件为弹簧管(见波登管),它的自由端与差动变压器的衔铁相连。当压力作用使弹簧管自由端移动时,衔铁随之移动,使差动变压器次级线圈的输出电压发生变化,再通过标定换算即能测出压力。图b中的弹性敏感元件为膜盒。在无压力作用时,接于膜盒自由面中心的衔铁位于差动变压器的中部,使输出电压为零。当压力输入膜盒后,自由面产生一正比于被测压力的位移,并带动衔铁在差动变压器的线圈中移动,从而使差动变压器有一正比于压力的电压输出。这种传感器适于测量微压力,可测量-4×104~6×104巴的压力,输出电压可达50毫伏。图c的弹性敏感元件为膜片。当高压流和低压流分别通过高压阀和低压阀进入高压室和低压室时,膜片在压力差作用下变形,向低压室移动,使连接其上的拉杆带动衔铁移动,从而使差动变压器输出与压差成一定关系的电压信号。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条