说明:双击或选中下面任意单词,将显示该词的音标、读音、翻译等;选中中文或多个词,将显示翻译。
您的位置:首页 -> 词典 -> 强迫水冷
1)  forced water cooling
强迫水冷
2)  forced cooling
强迫冷却
1.
This article introduces forced cooling method and actual cooling procedure for an 1 175t/h boiler, analyses this procedure.
介绍了 1 1 75t/h锅炉采用强迫冷却方法和实际冷却过程 ,并且对冷却过程进行分析 ,应用效果很好 ,缩短锅炉停炉后冷却时间 ,值得借
2.
The paper analyses the factors that affect heat transfer coefficients during forced cooling of steam turbine rotors, offers an approximate calculation method for the coefficients and presonts satisfactory calculation results of a 600MW turbine rotor.
该文分析了汽轮机转子在强迫冷却过程中影响换热系数的各种因素 ,提供了一种换热系数的近似计算方法 ,并对 6 0 0MW汽轮机转子进行了计算 ,其结果是满意的。
3)  forced-air cooling
强迫风冷
1.
A forced-air cooling system for a 230W power amplifier module is introduced in this paper,as well as the CFD software simulation of the cooling performance.
介绍了某功放模块的强迫风冷设计方案,并通过CFD热仿真软件对温度场和风速场进行了计算分析。
4)  forced air-cooling
强迫风冷
1.
The paper introduced the technology research project in international public bidding of 2×1 000 MW forced air-cooling enclosed bus for Phase 2 of Guangdong Lingao Nuclear Power Station.
依据广东岭澳核电站二期2台1000MW发电机组采用强迫风冷母线国际招标书中的技术条件,进行研究,提出了强迫风冷离相封闭母线的发、散热计算程序;冷却用风速、风量、风压的计算条件及风机、冷却器的选择等问题,促进实现强迫风冷封闭母线国产化。
2.
With the advantages of convenience of design, ease of application and low cost, forced air-cooling with heat sinks and fans are now the most widely used cooling technology for electronic devices.
散热器和风扇组合的强迫风冷技术具有设计简单、使用方便、成本低廉等优势,是目前电子设备中应用最广泛的冷却技术。
3.
The forced air-cooling enclosed bus-bar is the development trend of the enclosed bus-bar.
强迫风冷封闭母线是封闭母线发展的趋势。
5)  forced air-cooled
强迫风冷
1.
This paper has created the heat balance equation and analyzed the temperature rising law of forced air-cooled enclosed bus-bar mainly from the perspective of generating heat.
从封闭母线发热的角度出发,建立热平衡方程,计算分析强迫风冷封闭母线的温升规律,为强迫风冷在大功率大电流封闭母线中的应用提供了有力的理论支持。
6)  forced air cooling
强迫风冷
1.
Based on a typical forced air cooling electronic equipment,the accuracy and reliability of heat analysis module of electronic equipment structure optimization supporting software are proved through comparing the test data with the simulated results.
以典型强迫风冷电子设备为例,通过将热测试的试验数据与电子设备结构优化设计支撑软件热分析子系统仿真出的结果相比较,进一步验证电子设备结构优化设计支撑软件热分析模块的分析精度,检验其在工程实践中的可靠性,为工程技术人员提供可参考的资料和数据。
2.
Aiming at the thermal design problem of high-power components in electronic equipments, this paper introduces one practical thermal design method of forced air cooling of electronic equipment.
针对电子设备中高功率器件的热设计问题,介绍了一种实用的强迫风冷散热设计方法。
补充资料:动力机械:水冷壁

敷设在锅炉炉膛内壁﹑由许多并联管子组成的蒸发受热面。水冷壁的作用是吸收炉膛中高温火焰或烟气的辐射热量﹐在管内产生蒸汽或热水﹐并降低炉墙温度﹐保护炉墙。在大容量锅炉中﹐炉内火焰温度很高﹐热辐射的强度很大。锅炉中有40~50%甚至更多的热量由水冷壁所吸收。除少数小容量锅炉外﹐现代的水管锅炉均以水冷壁作为锅炉中最主要的蒸发受热面。


 水冷壁按结构分为光管式和膜式两种。


 光管式水冷壁 由一般的锅炉钢管组成(图1 光管式水冷壁 )。管子排列越密对炉墙保护效果越好。炉墙广泛采用轻质耐火材料和保温材料。这些材料可以砌成炉墙﹐也可敷设在水冷壁上成为敷管式炉墙以便于安装。


膜式水冷壁 将鳍片管(或扁钢与光管)相互焊接在一起组成的整块管屏(图2 膜式水冷壁 )。它的优点是气密性好﹔管屏外侧仅需敷以较薄的保温材料﹐炉膛高温烟气与炉墙不直接接触﹐有利于防止结渣﹔管屏可在制造厂成片预制﹐便于工地安装。


水冷壁材料 一般用碳素钢。锅炉压力在14兆帕以上时也有部分用合金钢的。管子外径﹕自然循环锅炉一般用51~83毫米﹔多次强制循环锅炉和直流锅炉一般用22~60毫米。直流锅炉的水冷壁不像自然循环锅炉那样一定是直立式的﹐也可以是水平围绕或其它形式的。参数高时﹐尤其在直流锅炉中﹐为了在炉膛高热负荷区防止传热恶化﹐常采用内螺纹管或在管内装设扰流子(图3 内螺纹管和管内装扰流子 )。

说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条