1) partial discharge intensity
局部放电强度
2) local strength
局部强度
1.
Test for local strength of materials with double-holes micro-shearing method;
双孔微剪切法测定材料的局部强度
2.
Validity calculation of local strength for heavy vehicle Ro/Ro ship;
装载重型车辆的滚装船局部强度校核
3.
Checking method for ship local strength based on lath-beam assumption;
基于板条梁假设的船体局部强度检验方法
3) Partial discharge
局部放电
1.
Typical model design of partial discharge in transformer;
变压器局部放电典型模型设计
2.
Identification and countermeasures for interference source at site of partial discharge test;
现场局部放电试验中干扰源的识别和采取的对策
3.
Research on the on-line monitoring system for partial discharge of hydro-generators;
水轮发电机局部放电在线监测系统研究
4) PD
局部放电
1.
Preliminary Study on Signal Extraction Technology for PD Pulse Based on Independent Component Analysis;
局部放电脉冲信号ICA提取技术的初步研究
2.
Study of bubble development in transformer oils based on PD measurement in negative point-plane gaps;
基于负极性下局部放电测量的变压器油中气泡发展过程实验研究
3.
The PD Detection of GIS in Service Using UHF-Acoustic Method;
运行中GIS局部放电超高频-超声波的联合检测
5) partial discharge(PD)
局部放电
1.
This paper introduced the work principle of Ultrasonic to measure partial discharge(PD)in transformers,and the composition of positioning system.
阐述了超声波测量变压器局部放电的机理及定位系统的组成、局放超声波信号的频谱分析、定位算法的实现,最后指出超声定位的注意事项及局限性。
2.
The key techniques about the sensing,data acquisition and processing,pattern recognition and calibration of ultra-high-frequency (UHF) signals are illuminated and the present status of field applications of on-line UHF partial discharge(PD) detection method is summarized in this paper.
从传感器、超高频信号的采集处理、信号的模式识别及超高频信号的标定等几个关键技术出发,对超高频法在电力设备局部放电在线检测中的应用现状进行了综述,并对超高频法在实际应用中存在的问题进行了探讨。
3.
It is difficult to measure the partial discharge(PD) signals because the signals may be submerged or flooded when the surrounding noises are severe.
局部放电极易被噪声污染,众多干扰中载波通讯、高频保护、无线电广播等周期干扰尤其严重,而窄带干扰严重时可能完全淹没局部放电信号,这给局部放电的检测工作带来了巨大困难。
6) partial discharge (PD)
局部放电
1.
Obtaining the partial discharge (PD) characteristic is one of the key issues of PD ultra-high frequency (UHF) detection.
获取局部放电(PD)特征信息是局部放电特高频(UHF)检测的关键问题之一,研究UHF信号与PD脉冲电流之间的关系有助于绝缘缺陷的诊断。
2.
The selections of center frequency and bandwidth are very important to detection, calibration and pattern recognition of ultra-high-frequency (UHF) partial discharge (PD) signals in transformers.
变压器局部放电特高频检测中,检测频率和带宽的选取对于放电信号的提取,进而对放电的标定及局部放电模式识别特征的保留具有决定作用。
3.
A new-type external antenna of ultra high frequency (UHF) partial discharge (PD) detection system is designed according to the wave-guide structure of gas-insulated metal-enclosed switch gear (GIS) and the wide band frequency spectral features of PD excited by electromagnetic waves.
根据气体绝缘的金属封闭式组合电器(GIS)的波导结构及局部放电脉冲所激发的电磁波的宽频带特征,建立了外部天线超高频局部放电检测系统。
补充资料:局部放电
局部放电 partial discharge 电力设备绝缘在足够强的电场作用下局部范围内发生的放电。这种放电以仅造成导体间的绝缘局部短(路桥)接而不形成导电通道为限。每一次局部放电对绝缘介质都会有一些影响,轻微的局部放电对电力设备绝缘的影响较小,绝缘强度的下降较慢;而强烈的局部放电,则会使绝缘强度很快下降。这是使高压电力设备绝缘损坏的一个重要因素。因此,设计高压电力设备绝缘时,要考虑在长期工作电压的作用下,不允许绝缘结构内发生较强烈的局部放电。对运行中的设备要加强监测,当局部放电超过一定程度时,应将设备退出运行,进行检修或更换。 |
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条