说明:双击或选中下面任意单词,将显示该词的音标、读音、翻译等;选中中文或多个词,将显示翻译。
您的位置:首页 -> 词典 -> 接地法兰
1)  earthed flange
接地法兰
2)  Flange Joint
法兰接头
1.
Finite Element Analysis and Optimum Design of the Failure of the Inlet Pipeline on the Smoke Gas Machine and its Flange Jointsin a Catalyst Cracking Plant;
催化裂化装置烟机入口管线及其法兰接头失效的有限元分析及优化设计
2.
In this paper, only based on the current application of the flange joints used in the liquidated gas stations, the problems existing were discussed, some of which should be improved or, at least, be attached importance.
影响法兰接头密封性能的因素很多,本文也仅仅结合当前液化气站法兰接头应用的现状和存在问题进行分析并提出改进或应引起重视的几个问题,供有关部门参考。
3.
In order to solve the leakage problem of the flange joints in braking pipeline system for present freight cars,analysis and investigation are made on the present flange joints structure and operation of freight cars in field,and improvement is made on the flange joints.
为解决现有货车制动系统管系法兰接头漏泄问题,对现有货车用法兰接头结构、现场运用情况等进行了分析、调查,并对法兰接头做了较大改进。
3)  flanged joint
法兰连接
1.
Fault tree analysis of flanged joint system at high temperature;
高温法兰连接系统的故障树分析
4)  seat-joined flange
接座法兰
1.
The process improvement of seat- joined flange is introduced, and its punching process procedure and the key points in die design under the condition of lots manufacture are briefly analyzed.
介绍了接座法兰的工艺改进,简要分析了批量生产条件下其冲压工艺过程及模具设计要点,并阐述了机加工件改冲压件的优点、可行性、经济性等。
5)  flanged connection
法兰连接
1.
Cyclical stress calculation of bolts for flanged connections at elevated temperature;
高温法兰连接系统螺栓循环应力确定
2.
Life expectation method of flanged connections based on creep analysis at elevated temperature;
基于蠕变的高温法兰连接系统寿命预测方法
6)  flanged joint
法兰接头
1.
Creep relaxation of bolted flanged joints often gradually results in residual stress reduction of the gasket,which gradually makes the joints reliability lower and finally leads to leakage failure at elevated temperature.
长期工作在高温下的螺栓法兰接头,由于密封垫片和螺栓的蠕变松弛,使得垫片上的残余应力逐渐减小,法兰接头的密封可靠性逐渐降低,并最终导致泄漏失效。
2.
The static temperature field distribution of flanged joints was simulated by 3-D FEA,the results show that the calculative values accord well with data of the measurement.
利用3-D有限元法模拟了法兰接头的稳态温度场分布,结果表明计算值与实测数据吻合较好。
补充资料:电力系统中性点接地变压器接地


电力系统中性点接地变压器接地
earthing transformer for neutral grounding

d旧n]一x .tong之hongx旧gd一onj旧d一b旧nyoq一j旧d-电力系统中性点接地变压器接地(earthingtransformer for neutral grounding)电力系统中利用接地变压器获得中性点与大地连接,也称中性点辅助变压器接地。当系统中的变压器不具备接人电阻器或接地故障消除器的条件(例如变压器三相绕组为△接线或虽为Y接线但容量不符合要求)时,要利用辅助的变压器提供一个用于接地的中性点。这种变压器应具备零序阻抗低、激磁阻抗大、功率损耗小的特性。绕组为曲折(Z)接线的变压器符合要求,如图1(a)所示。它可以带二次侧绕组,也可以只有一次侧绕组。 这种变压器每相由匝数相等的两个串联分绕组组成,每个磁芯上的两个分绕组间以及它们对二次侧绕组的零序互磁为零。很明显,这种变压器的零序电抗XTo只为变压器一次侧绕组的漏电抗Xs,,即XTo-Xs;,而系统中性点与地之间的计算阻抗Z。为Z。一25,+Z。,其中Z。为中性点电阻器或电抗器的阻抗。见图1(b)。2.为激磁阻抗。见图2,YN,d接线的变压器二次侧绕组可以带一定负荷。从过负荷能力考虑已经知道.接YN,d接线的双绕组变压器中性点的接地设备的容t不应超过变压器额定容t的50%.由此可认为,当变压器额定容t按中性点接地设备的容t设计时,允许二次侧绕组带50%额定容t的负荷. 还有一种特殊接线的接地变压器和接地设备的组合,是1918年鲍赫(R.Bauch)发明的,故也称饱鹅变压器,见图3。变压器一次侧中性点直接接地,开口三角形接线的二次侧连接接地设备,这与一次侧中性点接有接地设备是等效的。单相接地时,不对称的电压可分解为对称的正序和零序,磁通也可分解为对应的分量。磁通人m、人。、人.需要极小的激磁电流,并对应于正序电压U.。、U、。、U。。,零序电压UO.对各相是一样的,故三个磁柱中有相同的磁通式,对零序磁通来说,变压器相当一个单相变压器,只不过分裂为3个磁柱和3个绕组,见图3(c)。单相接地时,这种变压器每个分绕组上的电压为少尹z‘一.哟.!|||一下咖l!补丰气l一!{屯犷!{屯享!孟=zl息)一刃川l|拍--l--﹄·图1绕组为曲折(Z)接线的变压器 (a)接线图.(b)零序阻抗图会‘价“相“压,·““”的““是中”点接地“备电流的1/3,即夸。因而变压器的额定功率为3x2‘会‘争即中性点接地设备“率”1.15倍。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条