1) over-current protective co-ordination
过电流保护配合
2) over-current protection
过电流保护
1.
Study of chain-type over-current protection for cascaded lines;
级联线路的链式过电流保护方案研究
2.
The problems in calculation of time cut-out over-current protection value for various stages of power system in San Steel Group Company is stated,the reason for not be able to select in that protection is analyzed with power network for 4# converter of Steelworks as example,some measures proposed.
阐述了三钢集团公司内部电力系统各级定时限过电流保护定值计算中存在的问题,以炼钢厂4#转炉供电系统为例分析了定时限过电流保护无法实现选择性的原因,提出了解决问题的对策。
3.
The article introduces demands for sensitivity of the over-current protection in power network and also deals with the measurements to improve the sensitivity.
主要介绍对供电系统中过电流保护装置灵敏度的要求,以及提高过电流保护装置灵敏度的措施。
3) overcurrent protection
过电流保护
1.
The development of the compositive experimental flat for the line overcurrent protection;
线路过电流保护综合实验平台的开发
2.
The paper introduces the rectifying principle of transformer s overcurrent protection and then expatiates compound voltage lockout overcurrent protection.
介绍了变压器过电流保护的整定原则,借以引出了复合电压闭锁过流保护,并对其工作原理和在实际中的应用进行了分析。
3.
A new type of overcurrent protection,phase-sensitive overcurrent protection based on sampled value of current,is suggested in this paper.
针对中低压电网中过流保护存在灵敏度低的缺点,提出了一种新型微机式过电流保护即基于电流采样值的相敏过电流保护,并分析了它的基本原理、具体的实现方法及可靠性问题。
4) over current protection
过电流保护
1.
Research of current measuring and reliability of over current protection in design of freguency converter;
变频器设计中电流检测方式与过电流保护可靠性的研究
2.
The causes of refusing action of over current protection when the short circuit arises at the beginning of distribution line have been theoretically analysed in this paper.
从理论上分析配电线路出口故障时,电流速断和定时过电流保护拒动的原因,从而阐明电流互感器的响应特性对电流保护有很大的影响,最后提出相应的对策。
3.
Selective overload protection,instant protection and fuse protection method are adopted to meet over current protection requirement.
针对电源通道过电流保护的要求,采用了选择性过载保护、瞬动保护和后备保险丝三种保护方法,达到了对多种过电流情况的保护功能。
5) U/V and O/C complex protection
复合电压过流保护
6) protection against overcurrents; overcurrent protection
过<电>流保护、过<电>压保护
补充资料:水电站过电压保护和绝缘配合
水电站过电压保护和绝缘配合
overvoltage protection and insulation coordination for hydropower station
别产生脉动磁场和直流磁场.会在健全相上产生幅值较高的谐振过电压。在水轮发电机的转子上加装阻尼绕组,可以限制过电压幅值,不危害发电机绝缘。 (3)铁磁谐振过电压。具有铁芯电感的设备,因系统操作和故障引起设备上电压增高或产生励磁涌流,都会导致铁芯饱和。在谐振频率下,当感抗与容抗值相等时,就会引起铁磁谐振过电压。一般引起铁磁谐振过电压有:①电磁式电压互感器引起的铁磁谐振;②非全相运行引起的铁磁谐振;③合带空载线路的变压器引起的二次谐波的铁磁谐振。对电磁式电压互感器引起的铁磁谐振,采用电阻阻尼谐振或采用消谐装置消除谐振;对非全相运行引起的铁磁谐振,采用同期性能较好的断路器;对合带空载线路的变压器引起的二次谐波的铁磁谐振,应避免这种操作方式。 操作过电压保护电力系统发生故障或操作的瞬时,由于稳态电压的变化而产生电压自由振荡,所形成的过电压。操作过电压种类较多,水电站常遇到的操作过电压有:间歇性弧光接地过电压;空载线路分、合(重合)闸过电压;空载变压器和并联电抗器分闸过电压;线路非对称故障分闸和振荡解列过电压等。 间歇性弧光接地过电压在中性点不接地的系统中,当单相接地故障电路超过一定数值时,将产生不稳定电弧,形成熄灭和重燃交替的间歇性电弧,导致电磁能的强烈振荡,并在健全相以致故障相中产生较高的过电压。过电压数值随接地方式不同而异,一般中性点绝缘系统不超过3.SU:。;消弧线圈接地系统不超过3.Zux:;电阻接地系统不超过2. SUx。。由于持续时间较长,对设备绝缘有危害,应尽量避免发生。对持续时间较短的弧光接地过电压,可采用无间歇金属氧化物避雷器加以保护。 空载线路分、合(重合)闸过电压空载线路在分闸过程中,当断路器触头间的绝缘恢复强度低于电压恢复强度时,断路器发生重击穿,使线路上电压发生振荡,产生分闸过电压。对3一66kV系统空载线路分闸过电压一般不超过4.oUx:;110一220 kV系统一般不超过3.OUx。。空载线路分闸过电压是控制220 kV及以下系统操作过电压绝缘水平的主要依据。采用不重击穿断路器是限制分闸过电压的有效措施。线路侧采用电磁式电压互感器,可泄放线路残余电荷,以降低触头间恢复电压,可避免断路器重击穿或降低重击穿过电压。330 kV及以上系统应采用不重击穿断路器。 空载线路合闸时,由于线路电感电容的振荡将产生合闸过电压。线路重合闸时,由于电源电动势与线路上残余电荷反极性,加剧了这一电磁振荡过程,使过电压进一步增高。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条