1)  earth faulted
故障接地的
2)  earth fault protection
接地故障的保护
3)  earthing fault
接地故障
1.
Analysis on electric fire caused by earthing fault and protection measures;
接地故障引起电气火灾的分析及其防范措施
2.
Electrical fire caused by earthing fault and protection measures;
接地故障引起的火灾及其防范
3.
Earthing fault is a kind of phenomenon of single phase short circuit, it may cause fire via three reasons with great danger, Introduction was made to the actual reasons for earthing fault which caused fire and its preventive measures.
接地故障是一种单相短路现象,它可通过三个起因起火,危险性很大。
4)  grounding fault
接地故障
1.
The diagnosis skills and monitoring device selection for grounding faults of DC system in substations;
变电站直流系统接地故障定位及检测装置选用
2.
Research on detection method for DC system loop net grounding fault;
直流系统环网接地故障检测方法
3.
Detection and analyses of a DC system grounding fault in a 220 kV substation;
一起220kV变电站直流系统接地故障查找及分析
5)  earth fault
接地故障
1.
Talk about how to prevent the occurring of the earth fault;
浅议如何防范接地故障的发生
2.
To ensure the safety of electricity utilization and to remove a hidden peril of electric fire,the reasons of electric fire and the fire caused by low-voltage electric circuit earth fault are analyzed.
为了保证安全用电 ,消除电气火灾隐患 ,对电气火灾及低压电气线路接地故障引起火灾的原因进行了分析 ,提出应严格执行国家标准规程、规范 ,在电气工程设计、施工等环节中采取切实可行的措
3.
The earth fault of Lingbao back-to-back HVDC system 220 kV side converter transformer and the protection action are described.
介绍了灵宝背靠背直流换流站220kV换流变压器阀侧套管接地故障过程和保护动作情况。
6)  ground fault
接地故障
1.
Medium voltage system ground fault diagnosis based on process analysis;
基于过程分析的中压系统接地故障诊断研究
2.
Combined with a design case for voltage transformer of 10kV busbars,the principle of using residual voltage winding to detect the ground fault and the cause of ferro-resonance coming into being are described.
结合10 kV母线电压互感器设计案例,首先阐述了利用剩余电压绕组检测接地故障的原理和铁磁谐振产生的原因,在此基础上分析了剩余电压绕组与消谐器配合实现微机保护的工作原理,最后介绍了微机消谐器在本案例中的运行情况。
3.
After the comparison with AC phase ground fault, it analyses the difference of single line disconnection and AC phase disconnection.
介绍了一起110kV输电线路B相断线故障及引起的其他故障,通过与AC两相接地故障的对比,分析了单相断线和AC两相接地故障现象的异同,为专业工作人员介绍了一种便捷的工作思路。
补充资料:电力系统中性点接地变压器接地


电力系统中性点接地变压器接地
earthing transformer for neutral grounding

d旧n]一x .tong之hongx旧gd一onj旧d一b旧nyoq一j旧d-电力系统中性点接地变压器接地(earthingtransformer for neutral grounding)电力系统中利用接地变压器获得中性点与大地连接,也称中性点辅助变压器接地。当系统中的变压器不具备接人电阻器或接地故障消除器的条件(例如变压器三相绕组为△接线或虽为Y接线但容量不符合要求)时,要利用辅助的变压器提供一个用于接地的中性点。这种变压器应具备零序阻抗低、激磁阻抗大、功率损耗小的特性。绕组为曲折(Z)接线的变压器符合要求,如图1(a)所示。它可以带二次侧绕组,也可以只有一次侧绕组。 这种变压器每相由匝数相等的两个串联分绕组组成,每个磁芯上的两个分绕组间以及它们对二次侧绕组的零序互磁为零。很明显,这种变压器的零序电抗XTo只为变压器一次侧绕组的漏电抗Xs,,即XTo-Xs;,而系统中性点与地之间的计算阻抗Z。为Z。一25,+Z。,其中Z。为中性点电阻器或电抗器的阻抗。见图1(b)。2.为激磁阻抗。见图2,YN,d接线的变压器二次侧绕组可以带一定负荷。从过负荷能力考虑已经知道.接YN,d接线的双绕组变压器中性点的接地设备的容t不应超过变压器额定容t的50%.由此可认为,当变压器额定容t按中性点接地设备的容t设计时,允许二次侧绕组带50%额定容t的负荷. 还有一种特殊接线的接地变压器和接地设备的组合,是1918年鲍赫(R.Bauch)发明的,故也称饱鹅变压器,见图3。变压器一次侧中性点直接接地,开口三角形接线的二次侧连接接地设备,这与一次侧中性点接有接地设备是等效的。单相接地时,不对称的电压可分解为对称的正序和零序,磁通也可分解为对应的分量。磁通人m、人。、人.需要极小的激磁电流,并对应于正序电压U.。、U、。、U。。,零序电压UO.对各相是一样的,故三个磁柱中有相同的磁通式,对零序磁通来说,变压器相当一个单相变压器,只不过分裂为3个磁柱和3个绕组,见图3(c)。单相接地时,这种变压器每个分绕组上的电压为少尹z‘一.哟.!|||一下咖l!补丰气l一!{屯犷!{屯享!孟=zl息)一刃川l|拍--l--﹄·图1绕组为曲折(Z)接线的变压器 (a)接线图.(b)零序阻抗图会‘价“相“压,·““”的““是中”点接地“备电流的1/3,即夸。因而变压器的额定功率为3x2‘会‘争即中性点接地设备“率”1.15倍。