1) glass for electrode
电极用玻璃
2) glass electrode
玻璃电极
1.
The Measuring Mechanism of Glass Electrode and Its Analysis;
玻璃电极的测量机制及分析
2.
For guaranteeing the accuracy of pH monitoring and control in electroplating wastewater treatment,the configuration of glass electrode and principle of pH measurement were introduced.
为了保证电镀废水处理中pH测控的准确性,介绍了玻璃电极的结构及pH测量的原理,指出了玻璃电极的缺陷(如高输入阻抗、电极的污染与腐蚀)对pH测控的影响,给出了电极清洗及pH计校正的一般方法,提出了自动报警或投药装置在使用中应注意的问题。
3.
Silver adhesive and silver wire were used to replace the silver/silver chloride wire and inner solution for the construction of solid connecting glass electrode.
本文采用银导电胶和银丝代替常规pH玻璃电极的内溶液和内参比,制作固体接触型pH电极。
3) electrode glass
电极玻璃
1.
The influence of La2O3 and ZrO2 on volume conductivity of electrode glass was studied-The test,designed to find glass compositions and use LCR conduction apparatus to measure their volume conductivity.
研究了稀土氧化物La_2O_3和过渡金属氧化物ZrO_2对电极玻璃的电极性能的影响。
4) pH glass electrodes
pH玻璃电极
1.
The structure, principle and properties of pH glass electrodes were reviewed.
对pH玻璃电极的结构、原理以及特性进行了综述。
5) glassy carbon electrode
玻璃碳电极
1.
The activated glassy carbon electrode obtained by electrochemical means could adsorb the lead cation in solution.
经电化学活化后的玻璃碳电极可吸附溶液中的铅离子。
2.
The present paper discusses characteristic of electrochemical oxidation of epinephrine at glassy carbon electrode(GCE) in pH3~7 constant ionic strength solution with cyclic voltammetry experiment.
探讨了肾上腺素在pH3~7恒离子强度溶液中、玻璃碳电极上的吸附现象,解析了表面超额Γ等一系列电极过程的动力学参数。
3.
In this paper methods of pretreatment of glassy carbon electrodes are studied.
本文研究了玻璃碳电极(GCE)的预处理方法,提出了最佳预处理条件;循环伏安法和旋转电极法测定表明 GCE 电化学面积与预处理方法无关;解释了经过电化学预处理后电极的催化性能并提出了预处理后玻璃碳电极(PGCE)的催化作用模型。
6) pH glass electrode
pH玻璃电极
1.
We sum up the ordinary decline law and the characteristics before the PH glass electrode loses efficacy through the contrast observation experiment,discuss the method of revising the PH observation data,compile the revising procedure,analyze the ordinary observation error and put forward the measures to improve observation precision.
经过对PH玻璃电极对比观测实验,总结其在日常观测中衰减变化规律,以及PH电极失效前所具有的特征;讨论了对现有PH观测数据进行修正的方法,并编著相关修正程序;分析日常存在的测量误差,提出提高观测精度的措施。
补充资料:玻璃电极
分子式:
CAS号:
性质:用对氢离子活度有电势响应的玻璃薄膜制成的膜电极,是常用的氢离子指示电极。它通常为圆球形,内置0.1mol/L盐酸和氯化银电极或甘汞电极。使用前浸在纯水中使表面形成一薄层溶胀层,使用时将它和另一参比电极放入待测溶液中组成电池,电池电势与溶液pH值直接相关。由于存在不对称电势、液接电势等因素,还不能由此电池电势直接求得pH值,而采用标准缓冲溶液来“标定”,根据pH的定义式算得。玻璃电极不受氧化剂、还原剂和其他杂质的影响,pH测量范围宽广,应用广泛。
CAS号:
性质:用对氢离子活度有电势响应的玻璃薄膜制成的膜电极,是常用的氢离子指示电极。它通常为圆球形,内置0.1mol/L盐酸和氯化银电极或甘汞电极。使用前浸在纯水中使表面形成一薄层溶胀层,使用时将它和另一参比电极放入待测溶液中组成电池,电池电势与溶液pH值直接相关。由于存在不对称电势、液接电势等因素,还不能由此电池电势直接求得pH值,而采用标准缓冲溶液来“标定”,根据pH的定义式算得。玻璃电极不受氧化剂、还原剂和其他杂质的影响,pH测量范围宽广,应用广泛。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。