2) harmonic component
谐波分量
1.
Detecting for fundamental positive,negative sequence and harmonic components based on two-dimension fan-in transfer vector;
基于二维扇合矢量的基波正序、负序及谐波分量检测法
2.
Null position residual voltage was mainly composed of fundamental wave and asymmetrical harmonic component.
就信号电机的零位剩余电压从机理上进行分析,零位剩余电压主要由基波分量及谐波分量组成;零位剩余电压产生的主要原因是铁心涡流磁滞的不均匀性,以及加工中造成的不对称性。
3.
From the band-pass property of wavelet function,a non-sinusoidal current signal is detected based on wavelet transform under different scales,the fundamental and harmonic components in the signal and their RMSes are obtained thereby.
从小波函数的带通性质出发,利用小波变换在不同尺度下对非正弦电流信号进行检测,由此得出了它的基波和谐波分量及其有效值。
3) fundamental component
基波分量
1.
A real time method for detecting the fundamental component of the line voltage under distorted circumstance is proposed in the paper.
提出了一种在电网电压畸变情况下依然适用的电网电压基波分量的实时检测方法。
2.
Calculating the fundamental component from fault transient signals quickly is a crux of microprocessor protective relay to operate in time.
提出了短窗积分提取基波分量法 ,即首先选定采样短窗及其上的一族基函数 ,由此建立积分线性方程组 ,通过解方程组得出基波分量的值 ,并给出了理论推证。
3.
This paper discusses the method by which fundamental components are calculated with Wallis function algorithm in computer relay protection, calculates the effect of nonperiodic components on the accuracy of Wallis function algorithm, probes into the measures removing the effect of nonperiodic components, and compares Wallis function algorithm with Fourier algorithm.
本文论述沃尔什函数算法在微机继电保护中计算基波分量的方法,计算非周期分量对沃尔什函数算法精度的影响,探讨消除非周期分量影响的措施,并对沃尔什函数算法与傅里叶算法进行比较和分析。
4) traveling wave ratio
行波分量
1.
The principle and method to tune the traveling wave ratio of the acoustic field of the microminiature thermoacoustic-Stirling engine was given.
研究了微型热声斯特林热机声场行波分量的调节原理和调节方法,指出采用分布驱动系统就可以实现声场行波分量的调节,进而通过实验初步验证调节混合声场中行波分量的可行性。
5) short-wave component
短波分量
1.
In this paper we determine the global plate boundary segments with different width and calculate the long-wave and the short-wave components of the stress fields.
将全球板块边界带分别按照不同的宽度加以界定 ,计算了全球板块边界应力场的长、短波分量 ,讨论了应力场短波分量对观测应力场的相对贡献 ,分析了其与板块边界相互运动类型的相关性 。
2.
Assuming that the long-wave component of sHmax is expressed by the absolute direction of plate motions, we can get the relative orientation and the magnitude of the short-wave component resulted from the local tectonic process or other factors with vector analytical technique.
根据应力场的叠加原理,得到由该地区局部构造运动等因素贡献的短波分量的相对大小和方向。
6) wavelet component
小波分量
1.
The dominant wavelet components of earthquake excitation for the nonlinear responses of reinforced concrete frames;
地震动中控制钢筋混凝土框架非线性响应的小波分量
补充资料:对称分量
由不对称三相相量分解而得的对称三相相量。一组不对称三相相量凔、妋、凗,当三者之和不为零(即凔+妋+凗≠0)时,可以分解成三组对称三相相量,它们分别是:零序分量,记为凔0,妋0,凗0;正序分量,记为凔1,妋1,凗1;负序分量,记为凔2,妋2,凗2。由于三相电力系统中有三相交流电机、三相输电线等三相电路元件,它们的电路参数在对称的运行条件下较便于确定,因而将非对称三相相量分解为三组对称分量便可分别考虑在每一相序的电压、电流作用下三相电路的工作情况,然后根据叠加定理得到三相电路的工作情况。
零序分量如图1所示,其特征是3个相量大小相等且同相。妋0=凔0凗0=凔0正序分量如图2所示,其特征是3个相量大小相等但不同相。三者按妋1滞后凔1,凗1滞后妋1,凔1又滞后凗1的顺序互差120°,即
妋1=a2凔1凗1=a凔1
式中
负序分量如图3所示,其特征类似正序分量,也是3个相量大小相等但不同相。不过,此时3个相量是按凗2滞后凔2,妋2滞后凗2,凔2又滞后妋2的顺序互差120°,即妋2=a凔2凗2=a2凔2三组对称分量与原不对称三相相量的关系如下:不对称三相相最可以是三相电压相量,也可以是三相电流相量。在三相不对称电路中,有的不对称电压相量和不对称电流相量只有两组对称分量。例如,不对称线电压相量,因必须满足KVL,即妭AB+妭BC+凗CA=0,故只含有正序对称分量和负序对称分量。
零序分量如图1所示,其特征是3个相量大小相等且同相。妋0=凔0凗0=凔0正序分量如图2所示,其特征是3个相量大小相等但不同相。三者按妋1滞后凔1,凗1滞后妋1,凔1又滞后凗1的顺序互差120°,即
妋1=a2凔1凗1=a凔1
式中
负序分量如图3所示,其特征类似正序分量,也是3个相量大小相等但不同相。不过,此时3个相量是按凗2滞后凔2,妋2滞后凗2,凔2又滞后妋2的顺序互差120°,即妋2=a凔2凗2=a2凔2三组对称分量与原不对称三相相量的关系如下:不对称三相相最可以是三相电压相量,也可以是三相电流相量。在三相不对称电路中,有的不对称电压相量和不对称电流相量只有两组对称分量。例如,不对称线电压相量,因必须满足KVL,即妭AB+妭BC+凗CA=0,故只含有正序对称分量和负序对称分量。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条