1) back-up safety
备用安全装置
2) stand-by
备用
1.
The stand-by feedwater pump should be put in service as soon as the operating pump is tripped out.
在高温、高压运行的环境下,给水泵出现机械故障的概率很大,因而要求当运行给水泵出现故障,备用给水泵能及时快速地响应,因此需具备一套完善的联锁保护设计方案。
3) reserve
备用
1.
Discussion of load resource in reserve market;
负荷参与备用市场的讨论
2.
Compensation fees for AGC is based on availability、regulating capacity,regulating speed,regulating precision and the response time,peak adjustment is based on losing energy and times of start-stop;reserve is based on reserve capacity and duration;reactive power and voltage support is based on the influence to active power;black start-up restore is based on the requirements .
从实用化出发,提出了我国现阶段电力市场辅助服务补偿机制的设计原则,并建立了AGC依据可用率、调节容量、调节速率、调节精度和响应时间、有偿调峰依据深度调峰损失电量及启停调峰次数、备用依据备用容量和备用时间、有偿无功调节依据无功调节对有功电量的影响、黑启动依据电网系统安全可靠要求来计算贡献量进行补偿的数学模型,特别针对我国调节性能优良的水电建立了有偿调峰弃水电量、无功调节损失电量的补偿机制数学模型。
3.
In the traditional vertically integrated utility, the generators always provide reserve without any payment.
在计划管理体制下,发电企业所提供的备用服务是无偿的;在较完善的电力市场机制下,则要通过科学、合理的备用服务定价来调动发电企业提供备用服务的积极性。
4) Standby
备用
1.
Utilizing the powerful functions and flexibility of the Harris 2020 switching system and the ADV digital dispatching system, we have realized the simulation training and standby function of dispatching system through extending hardware and flexibly applying software system.
利用H20 20交换机和ADV数字调度系统功能强大、应用灵活的特点,通过对现有系统硬件的扩充和软件的灵活应用,实现调度系统的仿真培训和备用功能。
5) power reserve
备用
1.
As one of the most important ancillary services, power reserves play a very important role in maintaining power system security and reliability.
备用辅助服务是电力系统的重要特征之一 ,关系到电力系统的安全运行与可靠性。
6) stand by
备用
1.
Introduce a sample of SDH application of automatic switching between duty and stand by communication channels.
研究了SDH的特点 ,探讨了SDH对提高电力通信可靠性的作用 ,并介绍了SDH在电力通信主备用传输通道自动切换中的实际应用。
2.
This paper discusses how to enhance the reliability of stand by channel.
叙述了提高衢州地区备用通道可靠性的具体措施。
3.
Discusses the factors and principles to be considered in determining the question of stand by units, according to the current design standard and handbooks, and recommends a few combination schemes for reference.
结合国内现行设计规范和手册中的有关规定,讨论了制冷机组备用应考虑的因素和原则,给出了机组备用的组合参考方案。
参考词条
补充资料:备用电源自动切换装置
备用电源自动切换装置
automatic transfer to stand-by supply
be(yongd旧nyt一anz一dongq旧hoon zhuongzhl备用电派自动切换装t(automati。transferto stand一by supply)当工作电源消失或当工作电压降低过多时.能将备用电源断路器快速合闸向负载恢复供电的自动切换装置。 自动切换的一次系统常用的设自动切换装置的一次系统接线有以下两种:①两个电源(两台变压器或两条线路)互为备用。正常运行时,两个电源分别工作,电源之间设有经常断开的自动切换断路器,当其中一个电源故障时,另一个电源通过切换断路器迅速投人而恢复运行。这种自动切换方式通常称为暗备用。两个电源需具有充分的容量,以便在故障情况下由同一个电源向两个负荷供电。②利用一个备用电源作多个工作电源的备用.当一个工作电源故障退出运行时,备用电源自动投人,这种方式通常称为明备用。 自动切换装里功能切换装置的接线具有以下基本功能:①当工作电源消失时,快速起动自动切换装里,投人备用电源;②当工作电源母线电压降低,由接在母线上的低电压继电器动作,进行切换;③备用电源自动投人装置只能动作一次;④工作电源母线故障时,备用电源不允许投人。 火力发电厂备用电源自动切换接线,常用的有慢速切换和快速切换两种方式。 慢速切换为工作电源断路器断开后,经延时,当电动机残压下降到电动机允许的安全电压后才实现自动切换。当工作电源侧断路器跳闸时,联动受电侧断路器跳闸,以起动备用电源自动投人装置。同时,在工作母线上装设单独的低电压起动装置,当工作电源电压降到安全值,即20%~30%额定电压以下,而备用电源母线上保持一定电压值时,使备用电源断路器合闸。慢速切换时间一般为0.5一1·5s。 快速切换装置主要用于300 MW及以上容量的发电机,这种切换方式对电动机的冲击及对机组热力系统的正常运行影响较小,切换过程平衡。实现快速切换的条件是工作和备用电源断路器必须快速动作,要求合闸及跳闸时间为0.06~0.085。