2) oil-filled electric equipment
充油电气设备
1.
This paper introduces the procedure of the oil-filled electric equipment oil gas chromatogram analyzing and malfunction diagnosing and gives the implementation of the gas chromatogram analyzing and malfunction diagnosing system, including options setup, data input and malfunction diagnosing.
介绍了对充油电气设备油进行气相色谱分析以及故障诊断的过程 ,并给出了气相色谱分析与故障诊断系统的设计与实现 ,系统包括参数设置、数据输入和跟踪分析及故障诊断等 3个模块 ,能够在各种充油电气设备油色谱分析的数据基础上 ,实现对充油电器设备的分析和故障诊断 。
2.
The theory of judging oil-filled electric equipment by chromatography was introduced.
简要介绍了利用色谱分析结果判断充油电气设备故障的原理。
4) equipment charge
设备充电〔加油
6) oil-filled equipment
充油设备
1.
Based on the analysis of electrical oil-filled equipment\'s oil level anomalies,we find out the reason of oil level abnormal,and the corresponding preventives and proposal are put forward.
充油设备油位异常是变电站运行中常见问题,通过对电力充油设备油位异常进行分析,找出油位异常的根本原因,并提出相应的解决措施和建议。
补充资料:充油型电气设备
分子式:
CAS号:
性质:将可能产生电火花、电弧或危险温度的带电零、部件浸在绝缘油里,使之不能点燃油面上方爆炸性混合物的防爆型电气设备。充油型设备的外壳防护等级不应低于规定值;外壳上应有排气孔,孔内不得有杂物。油量必须充足,最低油面以下油面深度不得小于25mm。设备的油面温度不应超过70~100℃,具体的因设备不同而异。
CAS号:
性质:将可能产生电火花、电弧或危险温度的带电零、部件浸在绝缘油里,使之不能点燃油面上方爆炸性混合物的防爆型电气设备。充油型设备的外壳防护等级不应低于规定值;外壳上应有排气孔,孔内不得有杂物。油量必须充足,最低油面以下油面深度不得小于25mm。设备的油面温度不应超过70~100℃,具体的因设备不同而异。