1)  air directional drilling
空气正循环钻井
2)  air
空气
1.
The Disturbing Analysis of the Chlorin Ion from the Sampling Case to the Concentration of HCl in the Air;
采样容器溶出氯离子对监测空气中氯化氢的干扰分析
2.
Determination of Volatile Organic Compounds in Environmental Air by Cryo-concentration/GCMS;
预冷冻浓缩系统与气相色谱-质谱联用测定空气中挥发性有机物
3.
Determination of Total Mercury in Air by Atomic Fluorescence Spectrometry;
原子荧光光度法测定空气中的汞
3)  Atmosphere
空气
1.
Organic vapor pollutants were monitored in the atmosphere of Changchun city from September, 1997 to July, 1998.
从1997年9月~1998年7月对长春市空气中气相有机烃污染物进行布点监测。
2.
Content of pollutant bacteria and mold in our campus atmosphere was tested using sedimentation plate method and with beef and Czapek s media in summer and winter respectively.
采用沉降平板法 ,选用牛肉膏培养基与察贝克培养基 (czpekmedium) ,分别在夏季与冬季检测了校园不同环境中空气污染细菌与霉菌的含量。
4)  Ambient air
空气
1.
Determination of 3 kinds of aldehydes in ambient air by Capillary Gas Chromatography;
毛细管气相色谱法测定空气中三种醛类污染物
2.
The indirect determining method of phosgene in ambient air by reversed-phase high performance liquid chromatography was set up.
,10 μm )为分析柱 ,甲醇 -水 (体积比为 70∶30 )为流动相 ,在 2 5 7nm波长处用紫外检测器检测 1,3 二苯基脲 ,建立了间接测定空气中光气的反相高效液相色谱法。
3.
An HVS-1000 high\|volume sampler was modified and the sampling efficiency enhanced,by adding a cartridge filled with XAD-2 and PUF under the filter to collect PAHs in the gas phase as well as in particle of ambient air.
改装了HVS-1000型大流量采样器,实际工作中用滤膜"XAD-2加PUF"同时采集空气颗粒物和气相中的PAHs,有效地提高了采样效率,并初步定量评价了PAHs在颗粒物和气相中的分配;用添加替代物的方法评价了预处理过程的回收率;用乙腈和水梯度洗脱、PAHs专用色谱柱分离、紫外检测的方法对USEPA规定的16种PAHs类优先污染物进行了定性和定量分析。
5)  air/air heat pumps
空气/空气热泵
1.
This paper fully sums up research of heat pump in Harbin Institate of Technogy in China from 1960 sto 2003, including development and research of heat pump equipments, research of air/air heat pumps air-conditioner,forecast analysis and evaluation of water-loop heat pump systems and heat pump stations in china, air source heat pumpwater chiller/heater and ground source heat pumps etc.
系统地总结了哈尔滨工业大学从20世纪60年代到2003年期间在热泵方面的研究工作,包括热泵设备的开发与研究、空气/空气热泵空调器的研究、水环热泵空调系统在我国应用的预测分析与评价、大型热泵站在我国应用的预测分析、空气源热泵冷热水机组和土壤源热泵等,展示了哈工大热泵科研工作的概况和取得的成果。
6)  air-to-air change cooling
空气对空气冷却
参考词条
补充资料:湿空气透平循环


湿空气透平循环
cycle of humid air turbine

至0.92,U=0.85,Z=0.4,T。=1673K,。一40时,HAT循环的甲可以高达0.59以上。通常,HAT循环的供电效率要比余热锅炉型联合循环高5%左右;在50纬负荷时,则会高20%。0.矗U吕O。即护一.一闷一自一,u=0.75U一0. 70U .0.665 10 15 20 26 30 35 40 45tT:~eonst,Z=const时刃=f(。,U)的关系肠44貂n nlo左︸ 图T.一1673Kwloo咖几=压573KT’ .1473KT.一1373Kx吕0。28U=0.66900朗7oo柳咖枷5 10 15即25 30 35 40 45,图SU=。onst,X=eonst时,二=f(。,几)的关系 HAT循环也能用于整体煤气化联合循环中,简称IGHAT,有利于提高供电效率,并使发电成本适当降低。增加,以及燕汽具有做功能力大的特点,同时中间冷却方案可以减少空气的压缩功,因而循环的比功很大;⑤湿空气中含有大量的水燕气,能抑制NO二的生成.其主要缺点则与程氏双流体循环相似,即:由于随燃气排向大气的水蒸气难于回收,需要设里较大容量的水处理设备.以便连续地向系统补充软水. 当设定了大气温度T,、低压压气机的等摘效率、高压压气机的等摘效率、嫩烧室的效率、各部分的流阻损失系数、湿空气透平的等摘效率以及高、低压压气机之间压比的分配规律之后,HAT循环的供电效率粉和比功。只是总温比(r一T。/TI)、总压比(目、回热器的回热度(U)和喷水燕发珍混倍率X的函数.式中T:是撰烧室出口处湿空气的绝对温度。X是指在燕发饱和器中因喷水燕发而进人空气的水蒸气的质量倍率,一般不宜超过0.4. 图2~图5中分别给出了甲~f(。,T。)、7一f(。,Z)、甲=f(。,U)和w=f(。,T。)的变化关系.由图可见,随着T。、X的增高,甲和w将相应地增大,但。则有一个随之增大的最佳压比£,和‘值,其值要比简单循环燃气轮机的大,例如:当T。~1473K,X-0.25,U=0.65时,。,=30一40。当U值增大时,,也将增高,但最佳。,值却是下降的。计算表明:倘若压气机的等嫡效率增至。.88,湿空气透平的等摘效率增。.晶Tt=1673KTt=1573KT.=1473KTt二1373KU=0.65 0。42图210 15 20 25 30 35 40 45U=。onst,X=eonst时刃=f(。,T。)的关系 厅 0.创护一护.-闷x二0.40答冀10 15加25加35 40 45,图sU一eonst,T。=eonst时刃=f(。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。