说明:双击或选中下面任意单词,将显示该词的音标、读音、翻译等;选中中文或多个词,将显示翻译。
您的位置:首页 -> 词典 -> 励磁低电压判据
1)  Low voltage excitation criterion
励磁低电压判据
2)  low voltage identification
低电压判据
3)  system low voltage criterion
系统低电压判据
1.
Based on the analysis of phase advance operation data and several accidents occurred in domestic power plants,it is pointed out that the system low voltage criterion cannot function reliably when field-loss occurs.
对发电机进相运行的实验数据以及国内已发生的电厂事故进行了分析,指出在机组失磁时,系统低电压判据往往不能动作,如果用该判据作为失磁保护出口跳闸的必要条件,则会使失磁保护拒动。
4)  excitation voltage
励磁电压
1.
According to the impedance characteristics of the generator and the characteristics of the change of excitation voltage,a relatively self- contained and integrated schem e is proposed.
根据失磁过程机端电压特性和励磁电压变化特性 ,提出了一种综合的、较为完备的计算机失磁保护方案。
5)  negative field voltage
负励磁电压
6)  field voltage ratio
励磁电压比
补充资料:励磁系统顶值电压倍数


励磁系统顶值电压倍数
excitation system ceiling voltage ratio

I一e}x!tongd旧gZh一d一onyo bershu励磁系统顶值电压倍数(exeitation systemeeiling voltage ratio)同步发电机的励磁系统在规定条件下能够提供的直流电压最大值与其额定励磁电压之比值。 励磁系统顶值电压越高,电压响应速度也越快,可提高励磁系统的自动调节性能,有利于电力系统的稳定运行.但是考虑到电机的绝缘强度和造价等因素,顶值电压值应受到限制。 中国国家标准规定励磁系统顶值电压:100 Mw及以上的透平发电机励磁系统顶值电压倍数一般不低于1.8,50 MW及以上水轮发电机不低于2,其他不低于1 .6。