1) single phase closing
单相合闸
2) single-phase reclosure
单相重合闸
1.
Analysis of transient process of zero-sequence current during single-phase reclosure;
单相重合闸过程中的零序电流暂态过程分析
2.
A novel method based on the dynamic wavelet transform to identify fault types for the adaptive single-phase reclosure on transmission lines,was proposed.
分析了输电线路发生单相接地故障时,永久性故障与瞬时性故障电弧燃烧的特性,提出一种基于动态小波变换的自适应单相重合闸故障类型的判别方法。
3.
Therefore single-phase reclosure is of beneficial to the stability of power system and the depression of over-voltage, which results in the failure of single-phase reclosure.
指出了750 kV输电线单相重合闸的应用前提是避免并联电抗器补偿给单相重合闸可能带来的谐振过电压问题,分析并提出了并联电抗器中性点小电抗的正确取值范围。
3) single phase reclosing
单相重合闸
1.
The system stability with different control measures including triggering generator,excitation adjustment and single phase reclosing are also studied.
利用电力系统分析综合程序(PSASP)进行仿真分析,在计算不同故障情况下的极限切除时间后,对有效提高机组稳定性的措施如切机控制、励磁调节及单相重合闸等进行了进一步计算。
2.
In the design of 500kV compact transmission line from Yuncheng to Tai’an, in which the structure of partial line adopts the structure of double circuit on a same tower, the restriction of secondary current and the time coordination of single phase reclosing are researched.
8s以上能保证该线路单相重合闸成功。
4) single-phase reclosing
单相重合闸
1.
Adaptive accelerating scheme for zero sequence current protection on single-phase reclosing;
单相重合闸自适应零序电流加速保护方案
5) single-pole reclosing
单相重合闸
1.
Study on accurate calculation for non-complete phases condition of double circuit line and its single-pole reclosing;
同杆双回线非全相运行的精确计算与单相重合闸研究
6) single-phase auto-reclosure
单相自动重合闸
1.
For transmission lines with two shunt reactors,this paper presents a novel method of identifying permanent faults for single-phase auto-reclosure.
提出一种适用于两端带并联电抗器的超高压输电线路的单相自动重合闸永久故障识别方法。
补充资料:电力系统合闸过电压
电力系统合闸过电压
energization overvolt-age in electric power system
dianllx{tong触Zha guodlonyo电力系统合阐过电压(energization Over-voltage in electrie卯wer system)主要是指断路器合闸空载线路导致瞬态振荡所引起的过渡过程过电压。是决定330kV及以上的超高压电力系统操作冲击绝缘水平的主要依据。合闸过电压与合闸前线路上残留电压的大小、极性以及合闸时电派的相角有关。因为这些t均为随机变量,所以合闸过电压具有明显的随机性.若合闸前线路上有较高的残留电压,又恰好合闸于极性与线路残留电压相反的电源电压时,合闸过电压最大。三相重合闸过电压(尤其是不成功的三相重合闸过电压)要比单相重合闸或无故障正常合闸过电压高。合闸过电压还与系统容t、线路长度及结构有关,电源容盘小、线路长,合闸后的工频过电压商.合闸过电压更高;空载长线路沿线各点的合闸过电压幅值不等,对于无高压并联电抗器和进雷器的线路,最大过电压出现在线路的开路端,线路两端装有进苗器或高压并联电抗器时,最大过电压出现在线路的中部。 限制合闸过电压的主要措施有高压并联电扰器、进雷器和断路器并联合闸电阻,这些措施应综合考虑。高压并联电抗器主要是限制工频过电压。金属氧化物避雷器可以释放过电压的能t,将过电压限制到一定的水平,但它有一定的保护距离,靠近避雷器处的过电压可以限制得较低,随着离进雷器处的距离增大,限制效果逐渐减小。断路器并联数百欧姆的合闸电阻,可以将全线路的合闸过电压限制到较低的水平,但断路器加装合闸电阻使操作机构复杂,不仅使造价增大,而且使运行可靠性降低。对于超高压和特高压的长线路,首先应采用线路安装高压并联电抗器限制工预过电压,然后应用线路安装金属饭化物避雷器将合闸过电压限制到允许的水平,如以上措施还不能满足要求,再增加断路器加装合闸电阻的措施。 正在研制断路器受控合闸装t,即控制断路器在两端电位差为零或接近零时完成合闸,以使合闸过波过程降低至最弱程度,这对特高压交流摘电是必要的。该装置已在加章大运行,其长期使用可靠性还裕进一步在运行中检验。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条