说明:双击或选中下面任意单词,将显示该词的音标、读音、翻译等;选中中文或多个词,将显示翻译。
您的位置:首页 -> 词典 -> 磁信号预处理电路
1)  Magnetic pre-processing circuits
磁信号预处理电路
2)  ECG signal pretreatment
心电信号预处理
1.
In this paper, it introduces how to accomplish the funct io ns of ECG signal pretreatment and intelligent analysis in a new portable ECG mon itor.
为了适应便携式仪器的特征,我们在心电信号预处理中采用了FFT滤波和滑动平均滤波的方法去除各种干扰并使图像得以平滑,同时采用了差分阈值法提取特征点。
3)  signal processing circuit
信号处理电路
1.
Based on the analysis of signal produced and incremental measuring method, the circuit module for defending from repeating count is designed by using D trigger principle, and the circuit module for producing incremental signals and direction signals is designed by VHDL, so that the issue of increment signal processing circuit is solved.
介绍了增量式时栅位移传感器的工作原理,在分析信号产生及增量测量方法的基础上,采用D触发器工作原理设计了防重复计数电路模块,并采用VHDL语言设计了增量及方向信号产生电路模块,解决了时栅传感器信号处理电路的增量信号输出问题。
2.
A signal processing circuit of semiconductor magnetic head(SMH) made up of a InSn In eutectic film that was used in a circuit of money detector was designed.
设计了一种应用在袖珍验钞器电路中的采用锑化铟 -铟 (InSb In)共晶体薄膜型半导体磁头的信号处理电路 ,研究了这种电路的工作特性。
3.
The work principle of the PVDF piezoelectric-film sensor was presented,and the design of its signal processing circuit was also discussed.
介绍了聚偏氟乙烯(PVDF)压电薄膜传感器的工作原理,并设计了相应的信号处理电路。
4)  signal preprocessing
信号预处理
1.
Design and Implementation of Signal Preprocessing for Magnetorheological Fluid Damper Controller Based on DSP
基于DSP的磁流变阻尼器信号预处理
2.
In order to study the application of artificial neural network in gas analysis system,the article chooses gas sensor array and network model training samples to identify CH4 and CO,signal preprocessing algorithms is determined in the experiment.
实验分析确定了信号预处理方法,选取合适的网络模型并创新性的对用于气体种类识别的BP算法进行改进,并研究网络结构和参数的变化对气体分析系统性能的影响,实验结果证明气体传感器阵列与BP算法相结合进行气体成分分析具有一定的可行性,若能进一步调整及完善气体传感器阵列的硬件测量电路,则可开发出用于现实复杂环境的多气体分析系统。
3.
A gas sensor array is combined with artificial neural network which based on Back-Propagation algorithm to form a multi-gas quantitative analysis system,and experiments are done to analyze the influence of the signal preprocessing algorithms,the Back-Propagation network’s structure and parameters and the environment of quantitative analysis on the system’s performance.
将气体传感器阵列与采用BP算法进行训练的人工神经网络模式识别技术相结合形成混合气体定量检测系统 ,通过实验比较了不同的传感器信号预处理方法、BP网络的结构和参数 ,以及测量环境对混合气体定量检测系统性能的影
5)  signal pre-processing
信号预处理
1.
In order to solve the effect of high background noise and the difficulty of mixed fault diagnosis,the blind source separation technique was considered as a main tool of signal pre-processing and feature extraction.
针对高背景噪声的影响及混合故障诊断困难这一问题,采用盲源分离技术作为信号预处理与故障特征提取的主要工具,并应用这一新技术解决了故障曝气机WA5齿轮箱振动信号的故障诊断问题。
2.
Eddy current signal pre-processing techniques for noise elimination using the discrete wavelet transform and wavelet packet analysis methods are studied.
应用小波多分辨分解及重构技术和小波包分析技术进行检测信号预处理(噪声和干扰信号分离与去除)的基本原理,结合电涡流扫描检测实验,采用离散小波变换强制消噪法、软阈值消噪法和不同熵准则的小波包分析消噪法对检测信号进行预处理,并以SNR和RMSE为判断消噪效果好坏的标准,进行了效果的比较和优选。
3.
This paper discusses on two methods of eliminating the tendency item in the signal pre-processing,the mean slope method and the least square method,and simulates the algorithms by using the virtual instruments developing environment,LabVIEW,of American NI Company,and makes comparison of these two methods.
讨论了测试信号预处理消除趋势项的两种方法——平均斜率法和最小二乘法,使用美国NI公司虚拟仪器开发环境——LabVIEW对算法进行了仿真,并对这两种方法进行了比较。
6)  signal sample and disposal circuit
信号采集处理电路
补充资料:辐射探测器信号放大与读出电路
      核探测器输出的信号电平一般都很低,需要进行放大、成形、阻抗匹配等才能处理和记录。多丝正比室和漂移室等位置灵敏探测器(见高能粒子探测器)的每根丝都有信号输出,输出的路数很多,要求放大器和成形电路既简单又能满足后面处理设备对信号电平的要求。实现这些功能的各类电路通称为放大和读出电路。
  
  前端电路  直接与探测器系统相连接的电路。为了防止和减小信息的畸变和外部干扰,其位置紧靠着探测器系统,有时直接组装在探测器内。电路的输出具有较强的抗干扰能力和抗畸变能力,适合于较长距离的传送。例如,高能物理实验中多丝室信号读出电路就属于前端电路。在某些场合,把完成信号数字化的电路也放在前端电路内。
  
  前置放大器  直接与探测器连接、对探测器输出信号予以成形并进行预放大的电路。其位置紧靠着探测器,输出阻抗与电缆匹配,有较高的信号噪声比。信号因经过预放大而有较强的抗干扰能力,可以送到远离探测器的信息处理系统作进一步处理。
  
  低噪声前置放大器  噪声电平远低于信号电平的前置放大器,一般指等效噪声电荷低于5×10-17库的前置放大器。
  
  电荷灵敏前置放大器  这类放大器输出信号的幅度正比于探测器输出电流脉冲所包含的电荷量,与探测器电容和输入端的分布电容无关。它们起电荷积分器的作用,并具有相当大的输入电阻和输入电容。这类电路的基本结构,是用小容量电容器作反馈元件的负反馈运算放大器。
  
  弱电流放大器  一种放大10-10安以下的微弱慢变化电流的直流放大器。对弱电流放大器的要求是高输入阻抗和低漂移。现代水平已经可以达到放大10-16安以下的弱电流。在动态范围很大的情况下,还需要用对数放大器。
  
  快放大器  上升时间小的宽频带放大器。在核电子学中,快放大器上升时间在10-9秒量级。为了消除通过电缆传送信号时的反射,放大器的输入阻抗应与电缆的特性阻抗相匹配(典型值为50欧),输出端具有驱动输出电缆的能力,并应与电缆的阻抗相匹配。这类放大器可放大高计数率的信号或窄脉冲信号。
  
  谱仪放大器  用于能谱测量的主放大器。它的主要功能是:①进一步放大前置放大器输出信号,以达到供信号数字化所需要的电平。②成形滤波。将前置放大器输出信号再进行合适成形,用以提高信噪比,减小信号间堆积的几率或者判弃发生堆积的信号、减小基线涨落等,从而提高谱仪的分辨率。
  
  多丝室读出电路  各种多丝室和漂移室等位置灵敏型探测器的丝信号放大、成形和选通电路。
  
  ①多丝正比室读出电路:提取垂直于信号丝方向的位置信息,通常采用逐丝读出和延迟线耦合读出两种方法。逐丝读出是给每根信号丝(一般指阳极丝)接一个放大、甄别电路,把丝信号加以放大成形,然后进行编码和记录;延迟线读出是把丝信号耦合到均匀绕制的延迟线上,延迟线两端输出信号的时间关系与产生信号的丝位置有关。这样就将丝的位置信息转化为一对信号间时间关系信息。延迟线读出节省电路,定位精度高。但是,计数率不能太高,室也不能做得很大,而且对于多粒子事例的分辨本领差。沿丝方向位置信息的提取通常有三种方法:阴极重心读出、延迟线耦合读出和电阻丝做信号丝读出。
  
  ②多丝漂移室读出电路:根据带电粒子通过丝室平面的时间和丝信号出现的时间,确定电离点与丝的距离。漂移室读出事例出现时间、丝信号出现时间和丝号编码三种信息数字化后送计数机处理定位。
  

说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条