1) Liquid helium cryocondensation pump
液氦低温冷凝泵
1.
The working principle of NBI and the important function of the drift tube are introduced in details, A Liquid helium cryocondensation pump with a capacity of 20,000L/s is designed for the drift tube based on the analysis on 3 kinds of pumping mechanisms.
本文在详细介绍中性束注入器的基本工作原理和漂移管道在其中重要作用的基础上,通过对三种不同的抽气机理进行分析,为漂移管道设计了一台抽速为20,000L/s的液氦低温冷凝泵。
2) cryocondensation pump
低温冷凝泵
1.
It is a key issue to decrease the LHe consumption rate of cryocondensation pump of NBI.
降低中性束注入器低温冷凝泵的LHe消耗率,是进行低温冷凝泵设计时应考虑的核心问题之一。
2.
The performance of the cryocondensation pump mounted in main vacuum vessel is tested.
对布置于NBI主真空室的低温冷凝泵进行了低温抽气特性测试,结果表明,使用该泵能获得满足NBI要求的动态真空。
3.
Thus, a reference was provided for analyzing the working performances of cryocondensation pump and vacuum of nertralizer.
设计了中性束注入器低温冷凝泵内多点温度及中性化室真空度的远程数据采集方案,采用现场数据采集模块进行信号转换。
3) 4.2K LHe cryopump
4.2KLHe低温冷凝泵
5) cryogenic fluid pump
低温液泵
6) subcooling condenser
低温冷凝器
补充资料:液氦Ⅰ和氦Ⅱ(liquidHeⅠandHeⅡ)
液氦Ⅰ和氦Ⅱ(liquidHeⅠandHeⅡ)
在1大气压下,4He原子气体系统在温度为4.215K时开始液化,但因其零点能强,原子间的范德瓦尔斯(VanderWaals)吸引势能还不能使系统固化,到T=0K也仍然是液体,可称之为永久液体,需加压至25大气压才开始固化。在T=2.17K处,液4He的比热,体膨胀系数等有突变,发生λ-相变,相变后的液氦其黏性系数η<10-12Pa·s,比相变前的要小1011倍,呈现无黏滞的超流动性,而λ-相变前的液4He与正常液体属性一样。为区别这二种有差异的同原子4He液体,将λ-相变前的正常液体称液体HeⅠ,相变后的超流液体称液体HeⅡ。超流现象是一种宏观量子现象,只要其流速不超过临界速度,仍保持具有超流动性(参见“临界速度”)。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条