1) concrete of pump station
泵站混凝土
2) concrete pump
混凝土泵
1.
The analysis and precautionary measures of jamming pipe trouble of concrete pump;
混凝土泵堵管故障分析及预防措施
2.
Research on dynamic features during directional changing of pumping system for concrete pump;
混凝土泵泵送系统换向中动特性研究
3.
Simulation on pressure performance in direction changing of pumping system for concrete pump;
混凝土泵泵送系统换向过程压力特性仿真研究
3) pumped concrete
泵送混凝土
1.
The preparation technology of high-grade pumped concrete;
高标号泵送混凝土的配制技术
2.
Discussion on the design of pumped concrete mix proportion;
泵送混凝土配合比设计探讨
3.
Quality control of the pumped concrete construction in a building of dong fang square;
机制砂泵送混凝土施工质量控制
4) pump concrete
泵送混凝土
1.
Test of proportion of machine pump concrete and construction control;
机制砂泵送混凝土配合比试验及施工控制
2.
Research on the bulkily granular and high flowing pump concrete and its application;
大粒径高流态泵送混凝土的研究与应用
3.
Analysis on the causes and prevention measures of construction cracks of pump concrete;
泵送混凝土施工裂缝的成因分析和防治措施
5) Pumpcrete
泵送混凝土
1.
Prospect of application of pumpcrete mixed with fly-ash to construction of hydraulic tunnel;
掺粉煤灰泵送混凝土在水工隧洞工程中的应用前景
2.
Application of downward pumpcrete to build anti-scour wall on left bank of Shuibuya Hydropower Project;
向下泵送混凝土在水布垭枢纽左岸防淘墙施工中的应用
3.
This paper introduces the detection principle of rebound method and the main factors influencing the detection performance, and analyzes the modification of detecting the pumpcrete with rebound method.
介绍了回弹法检测原理及影响检测性能的主要因素,对回弹法检测泵送混凝土修正进行分析。
6) pumping concrete
泵送混凝土
1.
Analysis on causes of pumping concrete cracking and preventive measures;
泵送混凝土裂缝成因分析与防治措施
2.
Improved technique of pumping concrete;
改进的泵送混凝土施工工艺
3.
Preliminary discussions about reasons and preventions of crack in pumping concrete;
浅谈泵送混凝土裂缝成因与防治
补充资料:泵站电气设备
泵站电气设备
electric equipments of pump station
ILHa电流互感器ILHC测量表计电流表电流回路二ZLHa过电流保护卫川ZLHc电流继,二滓二沐.电器线圈+XMSYM 信号回路电动机事故跳闸信号继电器触点信号小母线 图艺高压异步电动机测量、保护接线图 当水泵的轴功率较小时,常选择鼠笼型异步电动机拖动。只有当供电变压器容量不能满足鼠笼式起动要求时,才选择构造较为复杂的绕线式异步电动机。如功率在500千瓦以上时,可选择同步电动机同步电动机可以提高电网的功率因数,减少输电线路的功率损耗电压损失,提高供电电压,效率较高,运行费用较低。但同步电动机构造复杂,它必须用直流电源供给励磁电流,所以在小功率情况下不宜选用。 鼠笼式异步电动机的起动,有直接起动和降压起动两种方式。当鼠笼式异步电动机的单机容量为供电变压容量的1/4及以下时,一般能直接起动。通过起动电压降及起动转矩等计算,选定直接起动或降压起动。同步电动机通常采用异步直接起动,但应进行起动校核。 磁力起动器作为鼠笼式异步电动机直接起动和保护的设备。星—一三角形起动器和补偿起动器用作鼠笼式异步电动机降压起动和保护的设备。绕线式异步电动机采用频敏变阻器起动。 高压开关有断路器、负荷开关和隔离开关三种。断路器和负荷开关在正常运行时能接通和断开负载线路,断路器还能切断短路电流。隔离开关在检修时能隔离电源。 低压开关有闸刀开关、转换开关,接触器和白动空气开关。后两者能切断额定负荷电流,自动空气开关还能切断短路电流。 熔断器的主要作用是切断短路电流,跌落式熔断bengzhan dianqi shebei泵站电气设备(eleetrie equipments ofPumP station)泵站变电、配电、用电设备的总称。 泵站的变电所(站)可以是专门的,也可以是与泵站附近工农业共同使用的。泵站变电所(站)的电压一般为110/6、35/6、35/0,4和10/0.4千伏。器还可以进行操作和兼用作隔离电源。 屋外配电装置一般采用避雷针作为直击雷保护装置,用阀型避雷器作为雷电入侵波的保护装置。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条