1) starting transients
启动暂态
2) starting transient
启动暂态过程
1.
The starting transient and steady state of solid state fault current limiter (SSFCL) incorporated into one-machine infinite-bus system is discussed in details.
详细分析了新型固态限流器对单机-无穷大系统启动暂态过程和稳态运行的影响,得出以下结论:启动过程中限流器直流电感的充磁使线路电流上升减慢;耦合变压器漏抗和桥路损耗等影响发电机功角和励磁电压;直流限流电感(电抗)与单机-无穷大系统联线阻抗之比越小,其启动充磁对系统的影响越小;耦合变压器漏抗越低,对系统稳态运行影响越小。
3) temporary disturbance
暂态扰动
1.
Secondly, the complex exponential method is adopted to acquire amplitude value、attenuation coefficient、frequency and phase angle of the PQ temporary disturbance signal on the basis of the latter-day digital signal processing theory.
然后在近代数字信号处理理论的基础上,提出采用复指数法获取电能质量暂态扰动信号幅值、衰减系数、频率和相角四个特征参数的方法,并且进行了有效性测试。
4) transient motion
暂态运动
5) cold start
冷态启动
1.
For the purpose of oil saving,by running a coal mill before joining network,a cold start experiment was carried out to a power unit of Jiangsu Ligang Electric Power Co.
介绍了江苏利港电力有限公司在机组冷态启动情况下,并网前投运磨煤机,采用以煤代油方式进行升温升压的试验情况,以此达到节约燃油的目的,并指出在此过程中的注意事项。
2.
Depending on application the plasma ignition technology in the corporation,the oil free ignition in boiler cold start was realized basically,and requests of boiler.
等离子点火技术在内蒙古大唐国际托克托发电有限责任公司的使用,使锅炉在冷态启动中基本上能够实现无油点火且能满足锅炉升温升压曲线要求,以达到节油降耗之目的。
6) cold startup
冷态启动
1.
Crank-Nicolson finite-difference method is used to calculate the temperature field in the rotor artificially during sub-critical 300MW steam turbine cold startup.
采用克兰克-尼科尔森差分法对亚临界300 MW汽轮机进行了冷态启动过程的转子温度场仿真计算,通过其结果分析,提出了运行建议。
2.
The article using finite-difference method to calculate the temperature field and the thermal stress field in the rotor during sub-critical 600MW steam turbine cold startup, by the analysis of the calculated results, give some suggestions for steam turbine operation.
利用差分法计算亚临界600MW汽轮机转子冷态启动过程中温度场和热应力场。
补充资料:变电所快速暂态电磁场
变电所快速暂态电磁场
fast transient electro-magnetic fields in substations
变电所中快速暂态电磁场强度由于开关操作暂态过程受多种因素影响.因此变电所中实际测t得到的场强数值分散性较大。不同电压等级变电所,用不同型式开关,实测得到的电场强度可达数十千伏/米(kV/m).磁场强度可达数百安培/米(A/m).美国对变电所中操作暂态电磁场的实测工作做的较多。作为一个例子,下表列出了美国电力研究院(EPRI)在115kV、250 kV、500 kV变电所中的实测结果。常规变电所内测点在母线下方地面,操作是断开一段短母线,一川纵潮洲娜朋洲川一0 0 0 0 0 00411:1l)即10 010加 ︵任守︸侧欲典匆 6 .0臼.《】火l()《a)T(5、留一。·““nlj 0 50几00 .,0.1 10 (任/A艺侧蔽2.()魂.硬)丫﹂)()口匕t卜卜片卜f乙仁0 t 0 0 0 0 005 .....-卜闭40加020化 (‘/V)侧旧要翻,::.:: l二‘.1.吐吐.吐2.《)4.(】6 .0划) 了卜卜┌────┬──────┐│ 一一J │八L,‘一’ ││习 ├──────┤│一一.1 │{犷V一· │└────┴──────┘0﹃-j门1 96,JD.任1 9 tl滩n乙oq乙 ︵三z淤巴侧翻要御 (一。一‘)洲.‘}12‘)一6(,义1‘,一‘, 喊d)T(5) 500 kV变电所内断开隔离开关时 的地面电场和磁场(a)GIS磁场;(b)GIS电场;(e)AIS滋场;(d)AIS电场b一and一onsuo kuolsu zonto一d一onelehong变电所快速暂态电磁场(fast transient elec-tromagnetie fields in substations)变电所中隔离开关切、合短母线时的暂态过程产生的电磁场。高压隔离开关操作时,触头间产生一系列电弧过程。