说明:双击或选中下面任意单词,将显示该词的音标、读音、翻译等;选中中文或多个词,将显示翻译。
您的位置:首页 -> 词典 -> 柔性接地
1)  neutral flexible ground
柔性接地
1.
By a lot of analyses for the medium-voltage distribution networks with different neutral ground techniques, the disadvantages of neutral resonance grounded mode and neutral flexible grounded mode have been proposed by in-depth analyses in this paper.
本文对中压配电网中性点接地方式,尤其是谐振接地方式进行了深入的分析,提出了中性点柔性接地方案。
2)  flexible joint
柔性接口
1.
Based on the construction experiences of the intercepting sewer main engineering in the urban area of Zhangjiakou City and the Yangfang ewer main engineering of Xuanhua City, this paper sums up the construction quality diseases in the flexible joints of drainage pipelines system, analyzes the reasons of these quality diseases, and puts forward some preventive measures.
根据张家口市主城区污水截流干管工程和宣化洋坊污水干管工程的施工经验,对市政排水管道系统中柔性接口施工质量通病进行了总结和归纳,分析了这些质量通病产生的原因,并提出了防治措施。
2.
This article describes the concrete and reinforced concrete drain pipes with spigot and socket, rebated socket or steel-collar socket flexible joints, and the process for their fabrication.
介绍上海市政排水管道常用的承插式、企口式和钢承口式柔性接口混凝土及钢筋混凝土排水管,及其这些排水管材的生产工艺。
3.
This paper researches the mechanical property of the ductile interface,and analyzes the seismic performance of the UPVC underground water pipeline covered with soil through the experiment analysis of the flexible joint of the UPVC underground water pipelines covered with soil.
目的通过UPVC地下供水管线柔性接口力学性能试验,分析覆土的UPVC地下供水管线的抗震性能。
3)  flexible joint
柔性接头
1.
Research on low modulus silicon rubber formula and interface adhesion technology for flexible joints;
柔性接头用低模量硅橡胶配方及界面粘接技术研究
2.
Study on ultrasonic detection for interface detection of flexible joint;
柔性接头的超声脱粘检测研究
3.
Nonlinear analysis on flexible joint with non-uniform elastomer;
变厚度弹性件柔性接头的非线性分析
4)  flexible docking
柔性对接
1.
This review will outline the recent progress in flexible docking and focus on the molecular dynamics simulation techniques.
这篇综述概要介绍分子柔性对接技术的进展并重点介绍分子动力学模拟技术。
2.
By using “tabu search” algorithm and Gehlhaar potential function, a new approach is presented for flexible docking of protein and its “drug like” ligand has been developed.
本文利用“禁忌搜索”算法和Gehlhaar简化能量势函数实现蛋白质与类药分子之间的柔性对接。
5)  flexible coalescent
柔性衔接
6)  connection flexibility
连接柔性
补充资料:电力系统中性点接地变压器接地


电力系统中性点接地变压器接地
earthing transformer for neutral grounding

d旧n]一x .tong之hongx旧gd一onj旧d一b旧nyoq一j旧d-电力系统中性点接地变压器接地(earthingtransformer for neutral grounding)电力系统中利用接地变压器获得中性点与大地连接,也称中性点辅助变压器接地。当系统中的变压器不具备接人电阻器或接地故障消除器的条件(例如变压器三相绕组为△接线或虽为Y接线但容量不符合要求)时,要利用辅助的变压器提供一个用于接地的中性点。这种变压器应具备零序阻抗低、激磁阻抗大、功率损耗小的特性。绕组为曲折(Z)接线的变压器符合要求,如图1(a)所示。它可以带二次侧绕组,也可以只有一次侧绕组。 这种变压器每相由匝数相等的两个串联分绕组组成,每个磁芯上的两个分绕组间以及它们对二次侧绕组的零序互磁为零。很明显,这种变压器的零序电抗XTo只为变压器一次侧绕组的漏电抗Xs,,即XTo-Xs;,而系统中性点与地之间的计算阻抗Z。为Z。一25,+Z。,其中Z。为中性点电阻器或电抗器的阻抗。见图1(b)。2.为激磁阻抗。见图2,YN,d接线的变压器二次侧绕组可以带一定负荷。从过负荷能力考虑已经知道.接YN,d接线的双绕组变压器中性点的接地设备的容t不应超过变压器额定容t的50%.由此可认为,当变压器额定容t按中性点接地设备的容t设计时,允许二次侧绕组带50%额定容t的负荷. 还有一种特殊接线的接地变压器和接地设备的组合,是1918年鲍赫(R.Bauch)发明的,故也称饱鹅变压器,见图3。变压器一次侧中性点直接接地,开口三角形接线的二次侧连接接地设备,这与一次侧中性点接有接地设备是等效的。单相接地时,不对称的电压可分解为对称的正序和零序,磁通也可分解为对应的分量。磁通人m、人。、人.需要极小的激磁电流,并对应于正序电压U.。、U、。、U。。,零序电压UO.对各相是一样的,故三个磁柱中有相同的磁通式,对零序磁通来说,变压器相当一个单相变压器,只不过分裂为3个磁柱和3个绕组,见图3(c)。单相接地时,这种变压器每个分绕组上的电压为少尹z‘一.哟.!|||一下咖l!补丰气l一!{屯犷!{屯享!孟=zl息)一刃川l|拍--l--﹄·图1绕组为曲折(Z)接线的变压器 (a)接线图.(b)零序阻抗图会‘价“相“压,·““”的““是中”点接地“备电流的1/3,即夸。因而变压器的额定功率为3x2‘会‘争即中性点接地设备“率”1.15倍。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条