2) two-photon absorption
双光子吸收
1.
The relationships between pn-junction and two-photon absorption of chromophores containing heterofluorene-or oxadiazole-unit;
含杂芴与噁二唑分子的p-n结与分子双光子吸收性能关系的研究
2.
Synthesis and strong two-photon absorption of carbazole derivatives: NT-G1 and NO-G1;
强双光子吸收化合物NT-G1和NO-G1合成与性能研究
3.
Studies on two-photon absorption cross-sections of 1,4-dimethoxy-2,5-divinyl-benzene derivatives;
1,4-二甲氧基-2,5-二乙烯基苯系列衍生物的双光子吸收截面
3) two photon absorption
双光子吸收
1.
The effects of metal ions and two photon absorption on the laser damage threshold of KDP crystals is also described.
本文回顾了近 10年来KDP晶体激光损伤阈值的研究进展 ,介绍了金属离子、瞬态双光子吸收对KDP晶体激光损伤阈值的影响 ,简述了金属离子和瞬态双光子吸收引起光热信号增强的关系 ,初步探讨了KDP晶体激光诱导损伤的机理 ,并对今后的发展方向提出了见
2.
In this paper,the principle of the optical storage using two photon absorption method was discussed.
本文讨论了用双光子吸收方法实现光存储的物理机制 ,并利用飞秒激光在光致抗蚀剂薄膜上进行双光子存储实验 ,测定了光致抗蚀剂的双光子激发阈值和损伤阈值 ,记录了点数据存储图。
3.
Difference between two transverse phase profiles about three photon and two photon absorption has been compared.
由此比较与双光子吸收情况下的非线性相移的不同。
4) two-photon absorption (TPA)
双光子吸收
1.
An autocorrelator based on ZnSSe two-photon absorption (TPA) photodetectors is demonstrated.
报道一种ZnSSe双光子吸收光电二极管的新型飞秒自相关器 ,其工作波长覆盖 40 0~ 80 0nm的极宽光谱范围。
2.
In order to search the materials with strong two-photon absorption (TPA) effect, good electrochemical and photochemical properties, we have done the researches as follows:1) Six ferroce.
我们的主要目的是寻求具有强双光子吸收效应和良好电化学性质、光化学性质的化合物。
5) increasing absorption optical bistablity
增强吸收光双稳
1.
And observed increasing absorption optical bistablity using nanosecond pulsed laser in ZnSe thin film at 77K.
报道了用常压MOCVD生长的Znse薄膜的光学非线代在77K下用纳秒脉冲激光观测到ZnSe薄膜的增强吸收光双稳特性非线性机理可能是由激子Coulomb相互作用屏蔽引起
6) two-photon absorption cross-section
双光子吸收截面
1.
Two-photon absorption process in organic molecules and experimental determination methods of two-photon absorption cross-section are discussed.
该文综述了非对称偶极型、中心对称型和多分支型双光子诱导荧光材料的研究进展,并介绍了有机分子的双光子过程及双光子吸收截面实验研究方法。
2.
2017cm/TW and two-photon absorption cross-sections was 950.
2017cm/TW,通过计算得到DCM的双光子吸收截面为950。
补充资料:单、双光子吸收法
单、双光子吸收法
SPA采用单一波长的γ射线125碘或241镅为发射源,计算其经过被测物后衰减率,再经一已知标准将其衰减值转换为骨矿含量或骨密度。通常只对四肢骨骼(如桡骨、尺骨)进行测量,并且主要测量皮质骨。为校正软组织产生的变异,测量时受检部位置于与软组织等当量的水袋中,采用多次扫描并取其均数,再除以受检骨的宽度,得骨的面密度,骨密度单位是g/cm2,其准确性约为6%,精确性在1%~2%,辐射剂量较小,通常低于10mRem(毫雷姆)。双光子吸收法(DPA)采用能发射两种不同能量光子的核素作放射源,利用高能和低能射线通过被测部位的不同衰减分布来计算骨的能量衰减分布,故可用来测量一些软组织变异大的部位如脊椎、髋等全身部位的骨矿含量,从而消除软组织及脊髓对测量结果的影响。DPA通常测量L1~L4的骨矿含量,结果以骨矿密度g/cm2表示。且辐射剂量较低,3~5μSv(4~6)。缺点为检查时间较长,并且DPA的测量是射线所经通路的衰减值的总和,无法区分皮质骨和松质骨的骨密度,另外,全身的骨矿含量的测量还受椎体边缘骨赘、椎体小关节肥大、压缩性骨折和钙化血管的影响。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条