1) the underground cold storage
地下冷库
1.
This paper discusses on building the underground cold storage in the northern area with rich natural cold sources in winter.
以冬季北方地区是否可以建造地下冷库的问题进行了讨论。
2) the ground cold storage
地上冷库
3) Cold storage floor
冷库地坪
1.
A 3-d steady heat transfer mathematical model of cold storage floor anti-freezing ventilation system was set up and simplified reasonably.
建立了冷库地坪通风防冻系统的三维稳态传热数学模型,对传热模型进行了合理的简化,根据系统的传热过程确定了传热模型的定解条件,利用PHOENICS软件对通风系统在不同通风流速下的传热模型进行了数值模拟分析。
4) groundwater reservoir
地下水库
1.
Characteristic parameters analysis of groundwater reservoir in Jining city,Shandong province;
济宁市地下水库特征参数分析
2.
Vulnerability assessment of Dagu River groundwater reservoir;
大沽河地下水库的脆弱性评价
3.
Sandy one-dimension circulating compression test and application to groundwater reservoir;
砂土一维循环压缩试验及在地下水库中的应用
5) underground garage
地下车库
1.
Function conversion design of underground garage and civil air defense works of medical treatment and rescue during peacetime and wartime;
地下车库与人防医疗救护工程平战功能转换设计
2.
Numerical study on application of inductive flow for smoke control in underground garage;
气流诱导技术在扁平地下车库的防排烟模拟研究
3.
The project accident analysis and the management of one underground garage;
某地下车库的工程事故分析与处理
6) underground storage
地下储库
补充资料:(GBJ72--84)冷库设计规范
冷库设计规范 GBJ72--84 主编部门:中华人民共和国商业部 批谁部门:中华人民共和国国家计划委员会 施行日期:一九八五年六月一日 关于发布《冷库设计规范》的通知 计标[1984]2363号 国家计划委员会 一九八四年十一月十五日 编制说明 商业部 一九八四年十月
中华人民共和国国家标准
根据原因家建委(78)建发设字第562号文的要求,由商业部会同有关单位编制的《冷库设计规范》,已经有关部门会审,现批准《冷库设计规范》XGBJ72-84为国家标准,自一九八五年六月一日起施行。
本规范由商业部负责管理,其具体解释等工作由商业部设计院负责。
本规范是根据原因家建委(78)建发设字第562号通知由商业部设计院会同上海轻工业设计院、湖北工业建筑设计院、天津建筑设计院、上海水产学院、中国水产科学研究院共同编制的。
编制过程中,遵循党的路线、方针和政策,进行了比较广泛的调查和科学试验,总结了我国三十多年来建设冷库的经验,曾两次征求了全国有关单位的意见,最后会同有关部门审查定稿。
本规范共分八章和七个附录。主要内容有总则、计算的一般规定、建筑、结构、制冷、电气、给水和排水、采暖通风和地面防冻。并将冷间设计温度和相对湿度、冷间围护结构总传热阻的确定方法、季节修正系数、墙排管、顶排管的传热系数和换算系数,以及主要城市地面下3.2米深处历年最低两个月的土壤平均温度等列入附录。
在执行本规范过程中,如发现需要修改或补充之处,诗将意见及有关资料寄交商业部设计院,以便修订时参考。
目录
第一章 总则
第二章 计算的一般规定
第三章 建筑