1) Cold Sense Coefficient
冷感系数
2) cold cracking susceptibity coefficient
冷裂敏感系数
3) cold and hot coefficient
冷热系数
4) refrigeration coefficient
制冷系数
1.
Further analysis of the effect on the refrigeration coefficient with the superheat of the refrigeration cycle;
制冷循环的过热对制冷系数影响的探讨
2.
The effect on the ratio of refrigeration coefficient with the super-cooling of the refrigeration cycle;
制冷循环的过冷对制冷系数比值的影响
3.
Based on the principles of classic thermo-dynamics,the paper has a therotical research in refrigeration coefficient of the ideal reversible Garnotcycle and the actual irreversible cycle.
从经典热力学的基本理论出发,对理想可逆卡诺循环和实际不可逆卡诺循环的制冷系数进行了理论研究,证明了理想可逆卡诺循环的制冷系数是最高系数,分析了实际情况下制冷系的制约因素,为提高制冷系数提供了理论指导。
5) COP
[英][kɔp] [美][kɑp]
制冷系数
1.
Optimization of cooling load and COP for an irreversible Brayton refrigerator with variable temperature heat reservoirs;
变温热源不可逆布雷顿制冷循环制冷率和制冷系数优化
2.
The analytical formulae about cooling load,COP(coefficient of performance),exergy loss rate,exergy output rate and ecological criterion of the irreversible refrigeration cycle are derived.
用有限时间热力学理论和方法分析了热漏、热阻和其它不可逆性对定常流普适制冷循环模型性能的影响,导出了由两个绝热过程、两个等热容吸热过程和两个等热容放热过程组成的不可逆制冷循环的制冷率、制冷系数、火用损失率、火用输出率和生态学性能,并由数值计算分析了循环过程对循环性能的影响特点。
3.
The analytical formulae about cooling load,COP,exergy loss rate,exergy output rate and ecological function of the endoreversible universal steady-flow refrigeration cycle consisting of one heating branch,one cooling branch and two adiabatic branches with heat resistance loss are derived.
用有限时间热力学方法分析了一类普适定常流内可逆制冷机循环,导出了存在传热损失时,由一个吸热过程、一个放热过程和两个绝热过程组成的一类普适的定常流内可逆制冷机循环的制冷率、制冷系数、损失率、输出率和生态学性能,并由数值计算分析了循环过程对循环性能的影响特点。
6) coefficient of performance
制冷系数
1.
Quantum degeneracy effect on the coefficient of performance from a Stirling refrigeration cycle;
量子简并对斯特林制冷循环制冷系数的影响
2.
The influence of coefficient of performance(COP) and quantity of refrigeration(Qref)were investigated with evaporating temperature and final desor.
采用不同浓度磷酸溶液浸渍法改性ZSM-5沸石分子筛,测定温度为303 K时不同浓度改性试样的饱和吸附量,筛选出最佳改性试样并测定其吸附等温线;在此基础上对最佳改性试样进行制冷性能预测,采用D-A方程简略式进行吸附制冷模拟仿真,探讨冷凝温度、脱附温度对系统制冷系数(COP)及制冷量(Qref)的影响。
3.
The experiment results show that the temperature difference between inlet and cold air outlet, the unit refrigeration and the coefficient of performance increases with the increase of the length of vortex tube under the same cold fraction with ambient temperature and inlet pressure of 0.
5Mpa的情况下,相同冷流率时,随着热端管长度的增加,涡流管的制冷温度效应、单位制冷量和制冷系数增加,而其制热温度效应无显著的规律;对同一热端管长的涡流管,随着冷流率的增加,涡流管的制冷温度效应、单位制冷量和制冷系数增加,且在冷流率为40%-50%时出现峰值,而制热温度效应随冷流率的增加而增加,在冷流率范围内未出现峰值。
补充资料:阀门技术注重流量系数和气蚀系数
阀门的流量系数和气蚀系数是阀的重要参数,这在先进工业国家生产的阀门资料中一般均能提供。我国生产的阀门基本上没有这方面资料,因为取得这方面的资料需要做实验才能提出,这是我国和世界先进水平的阀门差距的重要表现之一。
3.1、阀门的流量系数
3.1、阀门的流量系数
阀门的流量系数是衡量阀门流通能力的指标,流量系数值越大,说明流体流过阀门时的压力损失越小。
按KV值计算式
式中:KV—流量系数
Q—体积流量m3/h
ΔP—阀门的压力损失bar
P—流体密度kg/m3
3.2、阀门的气蚀系数
用气蚀系数δ值,来选定用作控制流量时,选择什么样的阀门结构型式。
式中:H1—阀后(出口)压
H2—大气压与其温度相对应的饱和蒸气压力之差m
ΔP—阀门前后的压差m
各种阀门由于构造不同,因此,允许的气蚀系数δ也不同。如图所示。如计算的气蚀系数大于容许气蚀系数,则说明可用,不会发生气蚀。如蝶阀容许气蚀系数为2.5,则:
如δ>2.5,则不会发生气蚀。
当2.5>δ>1.5时,会发生轻微气蚀。
δ<1.5时,产生振动。
δ<0.5的情况继续使用时,则会损伤阀门和下游配管。
阀门的基本特性曲线和操作特性曲线,对阀门在什么时候发生气蚀是看不出来的,更指不出来在那个点上达到操作极限。通过上述计算则一目了然。所以产生气蚀,是因为液体加速流动过程中通过一段渐缩断面时,部分液体气化,产生的气泡随后在阀后开阔断面炸裂,其表现有三:
(1)发生噪声
(2)振动(严重时可造成基础和相关构筑物的破坏,产生疲劳断裂)
(3)对材料的破坏(对阀体和管道产生侵蚀)
再从上述计算中,不难看出产生气蚀和阀后压强H1有极大关系,加大H1显然会使情况改变,改善方法:
a.把阀门安装在管道较低点。
b.在阀门后管道上装孔板增加阻力。
c.阀门出口开放,直接蓄水池,使气泡炸裂的空间增大,气蚀减小。
综合上述四个方面的分析、探讨,归纳起来对闸阀、蝶阀主要特点和参数列表便于选用。两个重要参数在阀门运用中 。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条