1)  phase shift
波长相移
2)  λ/4 phase shift
四分之一波长相移
3)  wave-length
波长
1.
Based on the CJ267-91,the text studies the effect of solvent,the preparation of the normative sample and the wave-length upon the result of mensurating mineral oils, so that it′s possible to choose the suitable condition to improve the accuracy of the mensurating results.
本文以CJ 2 6 7- 91为依据研究了溶剂、标准品的制备及波长三方面对测定矿物油类的影响 ,从而选择适宜的条件 ,提高了测定结果的准确度。
4)  wavelength
波长
1.
Determination of the Best Wavelength and Regression Equation of Ultra - Violet Spectrophotometer of 10 - Hy- droxy- Decenoic Acid (10 - HDA) in Pure Royal Jelly;
纯蜂王浆10-羟基癸烯酸紫外测定法最佳波长及回归方程的确定
2.
Influence of laser wavelength on depth of photoacoustic imaging;
激光波长对光声成像深度影响研究
3.
Effect of rail irregularity wavelength on lateral runningcomfort of speed-raised train;
线路不平顺波长对提速列车横向舒适性影响
5)  wave length
波长
1.
This paper presents the principle,formula derivation and detailed operation of an improved method for determining the asphaltene content through measuring the absorption degree of the sample suspension under incident beam of wave lengths of 750 nm and 800 nm.
介绍了一种用双波长分光光度法测定稠油中沥青质含量的改进法。
2.
The paper presents a mehtod for determining the wavelength of shallow water waves by using the wave dispersion equation and the influence of water depth,water flow, and wave amplitude upon the wave lengt
介绍了用波浪弥散关系确定浅水波长的方法 ,讨论了水深、水流、波浪振幅对波长的影
3.
Thestandard optical pyrometer of this pyrometers is the standard instrument used at thehigh temperature zone of the international practical temperation scale,But wanting to have the meas-ured temperature,the value of the effective wave length must be determined.
光学辐射高温计是高温测量中精度最高的仪器,其中的基准光学高温计是国际实用温标高温区的标准仪器,但欲得到被测温度,需确定有效波长值,本文探讨了影响有效波长的因素及其计算方法,并讨论了它对测量精度的影响。
6)  double-wavelength
双波长
1.
Absorbency at wavelength 510 nm and 390 nm were determined respectively with double-wavelength spectrophotometry,then iron and titanium in sample solution were detected.
分别在波长510nm和390nm测其吸光度,用双波长计算法,同时测定试液中的铁和钛。
2.
Methods:According to UV spectral properties of 2-MN and 2-MNQ in anhydrous alcohol, the equivalence absorbency double-wavelength UV spectrophotometry was adopted, and 275.
方法根据2-MN和2-MNQ在无水乙醇溶液中的光谱特征,采用等吸收点双波长法,选择275。
3.
A double-wavelength spectrophotometry was used to determine the Co~(2+) and Ni~(2+) content in nickel-cobalt alloy electrolyte simultaneously,using PAR-ethanol solution as developer.
提出采用双波长分光光度法同时测定镍钴合金镀液中Co2+与N i2+的含量。
参考词条
补充资料:射频和微波相移计量


射频和微波相移计量
RF and microwave phase-shift measurement

ShePinhe忱ibo xiangyi」iliang射频和微波相移计t(RF’ and而c~pha鱿一s撇~~ni)对射频和微波相移进行准确测量,并保证其量值统一的活动。 通常所谓的相移测量是指两个同频率的信号之间的相位差或相位移的测量,亦即网络相位移的测量。计量单位是耐、(o)、(’)、(”)。Ilad二(l8()j二)o;10二印‘;1‘二6以口。 常用移相器能提供固定或可变相移量的无耗二端口网络,称为固定或可变移相器。原始的移相器是精密的同轴或波导传输线。常用的射频和微波移相器如下:①伸缩线性移相器。通过改变传输线的机械长度来改变电长度,进而计算出相移量。②移动介质片型移相器。由空波导、薄介质片和传动机构组成,是波导系统中结构最简单和最常用的移相器。③旋转介质片型移相器。由三段波导组成,中间是可旋转的圆波导,两端为固定的方圆过渡波导,其相移量可达721护,分辨率为0.工。,测量不确定度可达0.矛。因其工作频带较宽,分辨率和重复性较好,常用作高频和微波相移传递标准。④反射型移相器。由定向拐合器和滑动短路器组成。人射波由定向藕合器主臂输人,输出信号经短路器反射后由定向祸合器旁臂翰出。当滑动短路器位置改变时,输出信号的相位就发生变化。理想情况下,相移的大小取决于波导波长和短路器的位移。采用精密调配反射计,相移的测量不确定度可达0.1“。⑤电控移相器。主要有二极管电控移相器和铁氧体电控移相器,可步进或连续可调。 相移测童方法主要包括: ①射频比较法。将被测移相器的相移与标准移相器的相移在同一频率上进行比较求得未知相移。标准移相器通常采用旋转介质片型移相器或反射型移相器。比较系统大多采用并联双通道系统,被侧移相器和标准移相器通道分别称为测量通道和参考通道。两个相移信号在非线性元件中组合。采用不同的非线性组合器件和不同的调制方式,将得到不同的射频比较系统:a.两个通道都不调制而采用连续波;b.两个通道采用同一个调幅信号源进行调制;c.被测移相器通道不进行调制,称为载波通道,但对标准移相器通道进行幅度调制,称为副载波通道。 ②频率变换法。通过外差变频或取样变频使待测信号转换成低频,而转换后得到的低频信号保留了待测信号的相位信息,这样就把射频或微波的相移测量变成了低频相移的测t。射频比较法需要采用准确度不高的射频或微波标准移相器,且其工作频带窄,而频率变换法克服了射频比较法的这些缺点,准确度大大提高。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。