1) Argon atmosphere
氩气环境
1.
In this research, we studied the quality improvement of laser microprobe emission spectrum line in argon atmosphere at reduced pressure.
以单脉冲YAG激光、YJGⅡ激光微区光谱仪、QF 60型水晶摄谱仪和自行设计的低真空装置组成分析系统 ,在减压氩气环境下 ,实验研究了铜合金光谱分析标准样品中的CuⅠ 32 4 。
2.
The effects of the height of auxiliary electrodes,the different pressures and the flux of argon on relative intensity of laser microemission spectra of aluminum alloy standard samples have been studied with the use of CCD in argon atmosphere at reduced pressure, using CuI 324.
以铝合金光谱分析标样中的Cu,Zn,Mg为分析对象,采用CCD数据采集处理系统,讨论了辅助激发高度、氩气气压和流量的变化对分析谱线相对强度的影响,实验表明:在减压氩气环境中,不同元素的谱线相对强度受实验条件影响不同;但在一定的实验条件下,各元素谱线相对强度均可达到最大值,具有高信噪比,可忽略基体效应对光谱分析的影响。
2) argon and wet oxygen environment at high temperature
高温氩气、湿氧环境
3) forced argon circulation
氩气强制循环
4) argon gas
氩气
1.
On-line analysis of trace water and oxygen in argon gas;
氩气中微量氧和水的在线分析
2.
Based on the working principles of gas chromatograph, DHP-05 type argon purity analyzer is applied to take overall analysis on the impurity gases of H2、O2、N2、CH4、CO、CO2 in the argon gas generated in air separator.
根据气相色谱分析的工作原理,运用DHP-05型氩气纯度分析仪对空分设备提取氩中的杂质气体—H2、O2、N2、CH4、CO、CO2进行全分析,通过对多年的氩气分析实践经验进行总结,阐述了气流波动、有机物变化、极化电压等各因素对氩气纯度分析的影响情况,并针对各因素的性质和特点,分别采取相应的措施进行调整和处理,从而找到氩气纯度分析的最佳工作条件,对仪器的一些不足之处进行了相应的改进,提高了氩气分析的准确性、重复性和及时性。
3.
The ion nitriding process with argon gas passing through hot-work die steel H13 was stated.
介绍了将氩气通入热作模具钢—H13钢的离子渗氮过程,用体视显微镜、光学显微镜、硬度计及X衍射分析仪等仪器,分析了氩气氛离子渗氮对H13钢渗层及其热疲劳性能的影响。
5) argon
[英]['ɑ:ɡɔn] [美]['ɑrgɑn]
氩气
1.
The Plan of Raising Quality and Output of the Argon;
提高氩气质量和产量的方法
2.
On-line analysis of impurities CO in loop of argon;
氩气回路中杂质CO的在线分析方法
3.
Effect of Argon Plasma Treatment on Mechanical Properties of Pylen Separating Membrane;
氩气等离子体处理对丙纶隔膜力学性能的影响
6) Ar
氩气
1.
Influence of Ar and Nz Flow Ratio on TiN Thin Films Prepared by Magnetron Sputtering
氩气与氮气流量比对磁控溅射法制备TiN薄膜的影响
2.
The mol heat contain ratio of Ar, O 2 and CO 2 gas is quickly measured and treated by a computer.
用计算机快速采集和处理数据,测量了氩气、氧气、二氧化碳气体的摩尔热容比,结果表明:对单原子分子气体实验值与理论值很好地一致;对多原子分子气体实验值与理论值有一定的偏差,说明能均分定理存在一定的局限性。
3.
The effect on the output power was studied,with different import positions,different dilution ratios and different buffer gases,N2,Ar,and CO2.
研究了稀释气进气位置、稀释比以及氮气、二氧化碳、氩气作为稀释气对kW级立式N2-COIL输出功率的影响。
补充资料:氩39-氩40法测年
分子式:
CAS号:
性质:将含钾样品放入核反应堆中接受快中子照射,40K核被打进一个中子,而后放出一个质子,形成39Ar,用质谱计测定被照射样品的40Ar/39Ar比值,代替常规钾-氩法中40Ar/40K比值,从而计算出样品年龄的方法,计算公式如下:t=λ-1ln(1+J•40Ar/39Ar)。式中J=39Ar/40Ar•λ/λkΔT∫φ(ε)σ(ε)dε是样品照射持续的时间,Ф(ε)是能量为ε时的中子通量,σ(ε)为39K(n,p)39Ar的反应截面,实验中用一已知年龄(ts)的标准与待测样品一块进行辐照,由下式求得J值:J=(eλt-1)/(40Ar/39Ar)。此方法解决了过去钾、氩分别由不同方法测定所产生的不同误差使年龄精度较低的弊端;同时由于照射后样品氩的释放可采用阶段加温方法,对一个样品便可获得一系列的表面年龄,最终得到代表矿物或岩石结晶的稳定坪年龄;或由等时线法处理得到样品的年龄、认识外来氩的混入状况。
CAS号:
性质:将含钾样品放入核反应堆中接受快中子照射,40K核被打进一个中子,而后放出一个质子,形成39Ar,用质谱计测定被照射样品的40Ar/39Ar比值,代替常规钾-氩法中40Ar/40K比值,从而计算出样品年龄的方法,计算公式如下:t=λ-1ln(1+J•40Ar/39Ar)。式中J=39Ar/40Ar•λ/λkΔT∫φ(ε)σ(ε)dε是样品照射持续的时间,Ф(ε)是能量为ε时的中子通量,σ(ε)为39K(n,p)39Ar的反应截面,实验中用一已知年龄(ts)的标准与待测样品一块进行辐照,由下式求得J值:J=(eλt-1)/(40Ar/39Ar)。此方法解决了过去钾、氩分别由不同方法测定所产生的不同误差使年龄精度较低的弊端;同时由于照射后样品氩的释放可采用阶段加温方法,对一个样品便可获得一系列的表面年龄,最终得到代表矿物或岩石结晶的稳定坪年龄;或由等时线法处理得到样品的年龄、认识外来氩的混入状况。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条