1) impedance estimation
阻抗估计
1.
Anisotropic Diffusion is introduced to impedance estimation,and Robust impedance estimation method(ADR) based AD is proposed.
本文通过分析各向异性扩散(Anisotropic Diffusion AD)在信号的去噪与增强中对特征的保护特性,及各向异性扩散与Robust估计之间的关系,把各向异性扩散引入到阻抗估计中,提出了基于各向异性扩散的Robust阻抗估计方法(ADR)。
2) estimation of road resistance
路阻估计
3) robust estimation
抗差估计
1.
Study of the robust estimation method of inter-satellite ranging network;
星间测距网的抗差估计方法研究
2.
Parameter robust estimation of reach flood concentration model;
水库入库河段洪水汇流参数抗差估计研究
3.
A new fault location algorithm for transmission line based on robust estimation theory;
基于抗差估计理论的输电线路故障定位新型算法
4) robust estimate
抗差估计
1.
Being different from the previous methods, used to detect gross errors in observations,such as statistical test and robust estimate, a new method named as “Quasi Accurate Detection of gross errors”(QUAD) has been proposed in ref.
以往检验粗差有两类不同的方法 ,一类是假设检验 ,另一类是抗差估计。
5) robust estimator
抗差估计
1.
After a brief review of robust estimator in this paper, a adaptive robust kalman filtering and a federated filtering based on it are presented.
简要介绍了抗差估计理论 ;在顾及扰动异常的情况下 ,把自适应抗差Kalman滤波应用到联邦滤波上 ,对联邦滤波进行了改进 ,提出了一种自适应抗差联邦滤波算法。
2.
They include median filtering,trend surface detection,and robust estimator.
简要介绍了现行的部分国内外多波束测深数据异常值检测算法,比较和分析了算法的各自优缺点,包括中值滤波、基于趋势面的测深异常检测、抗差估计异常值检测。
6) impedance design
阻抗设计
1.
Taking the particularity of the connection scheme of novel converter transformer and its filter system into account, it s necessary to find out the relation between its commutated reactance and short-circuit impedances between windings and fundament frequency impedance of filter branch for impedance design of novel converter transformer and reactive power .
考虑到新型换流变压器及其滤波系统的接线方案较为特殊,了解其换相电抗与绕组之间的短路阻抗及阀侧滤波支路的基频阻抗之间的关系,对新型换流变压器的阻抗设计和阀侧无功补偿度的优化配置是十分必要的。
补充资料:星接阻抗和三角接阻抗的变换
星接阻抗和三角接阻抗的变换
transformation between starc-onnected and delta-connected impedances
x ing]一e乙日kongl介e sonJ一00}Iez日伙ongde匕一。一〕huon星接阻抗和三角接阻抗的变换(t ransfor-mation betweenstar一eonneeted and delta-eonneeted imPedanees)接成星形的三个阻抗和接成三角形的三个阻抗互相替代的等效变换。它们之间的关系可用一组变换公式表示。按这组公式,用星接阻抗替换三角接阻抗或者反过来,不会影响稳态下电路其他部分的正弦电压和电流,常用于对称三相电路的分析和计算。 图1为三个阻抗21、Z:、23接成星形(又称丫形)。图2为三个阻抗Z小22。、Zal接成三角形(又称△形)。它们之间的变换公式如下:人23土图1星接阻抗图2三角接阻抗(1)将星形连接变换成三角形连接212一Z:+22+2 122及3一22+za十警(1)、|冬|矛231一23+21+2321(2)将三角形连接变换成星形连接z、-二一典乒兴-) 艺‘2士乙“3十乙31…_2 oqZI,}Z。一下万~一二-二二-汁 乙‘2士乙23十乙3‘1_Z。IZoq}艺q一二二一~二,二二--,-二二-~J 乙12十乙23十艺32夕(2) 当三个星接阻抗相等,即21一Z:一23一z丫、三个三角接阻抗相等即212一223一231一Z△时,变换公式是 Z二一32丫,Z丫一Z△/3
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条