说明:双击或选中下面任意单词,将显示该词的音标、读音、翻译等;选中中文或多个词,将显示翻译。
您的位置:首页 -> 词典 -> 钙化点
1)  calcification [英][,kælsifi'keiʃən]  [美][,kælsəfɪ'keʃən]
钙化点
1.
Edge detection of mammary calcifications based on behavior of ant colony and fuzzy Clustering;
基于蚁群行为及模糊聚类的乳腺钙化点边缘提取
2.
Study on Detection Methods of Calcification in Mammography;
乳腺X线影像中钙化点检测方法的研究
3.
Details of mammograph,such as calcifications breast,duct and other tissues in mammary image are enhanced effectively.
采用对比度受限自适应直方图均衡对乳腺图像进行增强,有效地增强了乳腺图像中的细节,如钙化点、乳导管等组织;并通过对算法中相关参数研究,得到应用于乳腺图像增强的参数优选值,以求获得较好的增强效果,为医师分析影像提供方便。
2)  microcalcification
微钙化点
1.
Methods of detection microcalcifications in digitized mammogram films;
乳腺钼钯X射线影像中微钙化点的检测方法
2.
Discuss and research in the methods of detection microcalcifications in digitized mammogram films;
数字乳腺X射线影像中微钙化点的检测方法的探讨与研究
3.
Research of CAD and Microcalcification Detection in Mammography;
乳腺X线图像中微钙化点检测及辅助诊断方法研究
3)  micro-calcification
微钙化点
1.
In this paper,SVM algorithm is applied to detect the micro-calcification.
本文首次将SVM算法用于乳腺X影像微钙化点自动检测中,对临床实际病例的试用结果表明,同目前常用的基于经验风险最小的人工神经网络(ANN)分类方法相比,SVM具有更高的识别率,值得应用推广。
2.
This paper proposed a feature selection method of micro-calcification(MC) in mammograms,which used weighted mutation based immune algorithm.
给出了一种乳腺X线照片微钙化点的特征选择方法,该方法运用基于加权变异算子的免疫算法进行特征优选。
3.
Mammography has become the most effective way to detection of breast cancer, and it is sensitive to clustered micro-calcification which is the key characteristic of early breast tumors.
细小、颗粒状的成簇微钙化点是乳腺癌早期的重要征象。
4)  microcalcifications
微钙化点
1.
To the question that the microcalcifications in the mammography are extremely small,various shapes,different sizes,variable distributions,and low contrast.
针对早期乳腺癌X光片中微钙化点非常微小、不规则、形状和分布各异,且对比度较差,乳腺中的致密组织与病变组织十分相似的问题,依据微钙化点是淹没在极高频噪声和低频背景中的高频信号,提出了利用数学形态学和小波变换来进行微钙化点的定位,依据神经网络可以通过训练来进行分类,提出利用概率神经网络对微钙化病变类型进行融合识别。
2.
A novel approach to computer aided microcalcifications detection in mammograms was presented.
针对乳腺X线摄片,提出了一种计算机辅助检测乳腺微钙化点的方法:首先利用灰度形态重构完成穹顶提取,除去乳腺背景结构同时又能很好地保留微钙化点;其次运用拉普拉斯算子在空间域内对图像进行锐化以增强微钙化点;然后在频率域内利用巴特沃思高通滤波器对图像进行高通滤波;最后利用二维最大熵阈值分割对图像二值化,从而检测出微钙化点并在图像上标识出来。
3.
The detection methods of microcalcifications in the digital mammograms are studied.
研究了乳腺钼钯X射线影像中微钙化点的计算机辅助检测问题 ,提出一种能发挥差值、小波及神经网络等多种技术优势的综合处理检测方法 。
5)  micro-calcifications
微钙化点
1.
It is very meaningful for early diagnosis of breast cancer with detecting micro-calcifications in breast cancer.
乳腺X线图像中微钙化点的检测对于乳腺癌的早期诊断非常有意义,然而目前常用的钙化点检测方法普遍存在假阳性高的缺点。
2.
To solve the problem of high false positive detection in micro-calcifications of mammogram, this paper presented a detective algorithm on micro-calcifications.
针对乳腺X线图像微钙化点检测假阳性高的问题,提出一种微钙化点检测算法。
6)  Microcalcifications in Mammograms
乳腺钙化点
补充资料:闭式单点、双点压力机
代码:00413
设备名称:闭式单点、双点压力机
型号规格:公称力≥800kN
计量单位:台
主要参数内容
国际先进国内先进国内一般国内落后评定方法及说明
(一)加工精度
    参照GB10924-89、GB10933-89、JB5200-91
1、滑块下平面对工作台上平面的平行度(mm)
30%精度储备20%精度储备达到规定值大于规定值 
0.02+0.10/100×滑块下平面的被测长度
     
2、滑块行程对工作台上平面的垂直度
30%精度储备20%精度储备达到规定值大于规定值 
0.05+0.02/100×滑块行程长度
     
(二)结构性能
     
1、离合器、制动器接通率,当滑块行程次数≤16次/分时为70%,≤25次/分时为60%,≤45次/分时为50%
大于规定值10%大于规定值达到规定值达不到规定值 
2、液压超负荷保险装置、微调装置、吨位指示器
全部具有全部具有部分具有没有 
(三)噪声dB(A)
     
1、公称力≤400kN
≤85≤87≤88>88 
2、公称力>400kN
≤87≤88≤90>90 
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条