1)  infrared measurement of temperature
红外比色测温/红外测温
2)  infrared
红外
1.
Fast Analysis of Gaseous Pollutant in Environment by Handy Fourier Transform Infrared Spectrometer;
便携式傅立叶红外快速检测环境中气态污染物
2.
Recognition of Plant Parts of Tobaccos Based on Infrared and Near Infrared Spectra;
基于红外与近红外光谱的烟叶部位识别
3.
Studying status of radar and infrared composite stealthy coating materials;
涂覆型雷达/红外复合隐身材料研究现状
3)  IR
红外
1.
Study on IR Extinction Performance of Graphite Micro-powder Smoke in Vacuum;
真空中石墨微粉烟幕的红外消光性能研究
2.
Preparation of Paraffin’s Microcapsule and Study on Its IR Simulation and Stealthy Performance;
石蜡微胶囊化及其红外伪装隐身性能研究
3.
The Compatibility of IR Smoke Interfering Material in Shell;
红外烟幕干扰材料在弹中的相容性
4)  FTIR
红外
1.
Component analysis and content determination by TG-FTIR for thermosetting compound;
红外与热失重结合解析酚醛复合材料的成分
2.
Synthesis and Characterization of Some Manganese Sulfonates by TG and FTIR;
几种磺酸锰盐的合成及其热重和红外表征
3.
The Fourier transform infrared spectroscopy(FTIR),ultraviolet-Visible spectroscopy(UV-visible),Fourier transform Raman spectroscopy(FT-Raman),and nuclear magnetic resonance spectroscopy(1H NMR) were used to study the oxidation of spruce lignin by chloride dioxide.
采用傅里叶变换红外光谱(FTIR)、紫外-可见光谱(UV-visible)、傅里叶变换拉曼光谱(FT-Raman)以及核磁共振(1H NMR)分析技术对云杉木质素被二氧化氯氧化前后的结构变化进行了研究。
5)  infrared spectrum
红外
1.
The infrared spectrum, ultraviolet spectrum, mass spectrum, 1[KG-*3]H- 1[KG-*3]H correlated spectroscopy( 1[KG-*3]H- 1[KG-*3]H COSY), ( 1[KG-*3]H detected) heteronuclear multiple-quantum coherence(HMQC), ( 1[KG-*3]H detected) heteronuclear multiple-bond coherence(HMBC) of simvastatin were reported and interpreted.
对辛伐他汀的红外(IR)、紫外(UV)、质谱(MS)、氢氢相关谱(1H1HCOSY)、碳谱(13CNMR,DEPT)、碳氢相关谱(HMQC)、碳氢远程相关谱(HMBC)予以解析并进行了报道,对所有的1HNMR和13CNMR谱信号进行了归属;讨论了红外特征吸收峰所对应的官能团的振动形式,并且对样品进行热差和热重分析,显示该样品为单一晶型,不含结晶水。
2.
The infrared spectrum, ultraviolet spectrum, mass spectrometry, 1H- 1H correlated spectroscopy ( 1H- 1H COSY), ( 1H detected)heteronuclear multiple-quantum coherence (HMQC), ( 1H detected)heteronuclear multiple bond coherence (HMBC) of Imiquimod were reported and interpreted.
对咪喹莫特的红外 (IR)、紫外 (UV)、质谱 (MS)、氢 氢相关谱 (1 H 1 HCOSY)、碳氢相关谱 (HMQC)、碳氢远程相关谱 (HMBC)予以解析并进行了报道。
3.
The infrared spectrum,mass spectrometry,()~1H-()~1H correlated spectroscopy(~1H-()~1H COSY),(~1H detected) heteronuclear multiple-quantum coherence(HMQC),(~1H detected) heteronuclear multiple bond coherence(HMBC) of delavirdine mesylate were studied.
讨论了质谱的主要碎片离子的可能裂解方式和红外特征吸收峰所对应的官能团的振动形式,为该类化合物的结构解析提供了分析依据。
6)  FT-IR
红外
1.
The structures of semifinished products were determined by FT-IR and the adsorption capacities to Ni2+ were comparatively analyzed,which validated the synthesis of P-C-CTS (Ni) in desirable processes.
通过不同吸附剂的红外光谱分析、含水率和Ni2+吸附容量的比较,验证了技术路线的正确性。
2.
,is a medicine raw material of domestic and international and tight lacking,This text expatiated the large instrument in application,with the living op- tical microscope and FT-IR spectrum and UV spectrum and fluorescence spectrum method to determined grade and con- tent of the prepared bilirubin in laboratory,and to attestation each other,and noticed the test term.
本文阐述了运用大型仪器,以生物光学显微镜、傅立叶红外光谱法、紫外分光光度法、荧光激发光谱法对实验室自制的胆红素的品位和含量进行了相互认证式测定,且注意了测试条件。
3.
12mg/g,and by FT-IRthe compositions were tested and verified.
12mg/g,并通过红外光谱测验,交叉验证提取物的成分。
参考词条
补充资料:红外测温仪的工作原理和技术问答
一、为何采用非接触红外测温仪? 

  非接触红外测温仪采用红外技术可快速方便地测量物体的表面温度。不需要机械的接触被测物体而快速测得温度读数。只需瞄准,按动触发器,在LCD显示屏上读出温度数据。红外测温仪重量轻、体积小、使用方便,并能可靠地测量热的、危险的或难以接触的物体,而不会污染或损坏被测物体。红外测温仪每秒可测若干个读数,而接触测温仪每秒测量就需要若干分钟的时间。  

二、红外测温仪如何工作? 

    红外测温仪接收多种物体自身发射出的不可见红外能量,红外辐射是电磁频谱的一部分,它包括无线电波、微波、可见光、紫外、R射线和X射线。红外位于可见光和无线电波之间,红外波长常用微米表示,波长范围为0.7微米-1000微米,实际上,0.7微米-14微米波带用于红外测温仪 

三、如何确保红外测温仪测温精度?

    红外技术及其原理的无异议的理解为其精确的测温。当由红外测温仪测温时,被测物体发射出的红外能量,通过红外测温仪的光学系统在探测器上转换为电信号,该信号的温度读数显示出来,有几个决定精确测温的重要因素,最重要的因素是发射率、视场、到光斑的距离和光斑的位置。发射率,所有物体会反射、透过和发射能量,只有发射的能量能指示物体的温度。当红外测温仪测量表面温度时,仪器能接收到所有这三种能量。因此,所有红外测温仪必须调节为只读出发射的能量。测量误差通常由其它光源反射的红外能量引起的。有些红外测温仪可改变发射率,多种材料的发射率值可从出版的发射率表中找到。其它仪器为固定的予置为0.95的发射率。该发射率值是对于多数有机材料、油漆或氧化表面的表面温度,就要用一种胶带或平光黑漆涂于被测表面加以补偿。使胶带或漆达到与基底材料相同温度时,测量胶带或漆表面的温度,即为其真实温度。距离与光斑之比,红外测温仪的光学系统从圆形测量光斑收集能量并聚焦在探测器上,光学分辨率定义为红外测温仪到物体的距离与被测光斑尺寸之比(D:S)。比值越大,红外测温仪的分辨率越好,且被测光斑尺寸也就越小。激光瞄准,只有用以帮助瞄准在测量点上。红外光学的最新改进是增加了近焦特性,可对小目标区域提供精确测量,还可防止背景温度的影响。视场,确保目标大于红外测温仪测量时的光斑尺寸,目标越小,就应离它越近。当精度特别重要时,要确保目标至少2倍于光斑尺寸。 

四、如何进行红外测温仪测温? 

说明:补充资料仅用于学习参考,请勿用于其它任何用途。