1)  electrical interruptive life
开断电寿命
1.
This paper uses fuzzy theory to make a comprehensive judgement on vacuum circuit breaker s electrical interruptive life and presents a method of how to deal with off line(or on line) data of each parameter.
作者应用模糊理论,对真空断路器开断电寿命进行综合评判,提出了各参数离线(或在线)数据的处理方法,使用二级评判模型对七种断路器进行评价,为全面、科学、准确地进行VCB实时在线监测和评判提供了新的方法。
2)  interruption life
开断寿命
1.
Several methods have been proposed for extrapolating the interruption life of vacuum circuit breaker contacts and these have resulted in many different claims.
通过几种不同方法来测量或推断真空断路器的开断寿命可能得到截然不同的结论 ,为了调解这些关于纵磁场熄弧真空断路器的不同结论之间的差异 ,并提供一个共同的解决办法 ,本文推荐一种新的基于开断水平及触头间燃弧时间的估算触头寿命的方法。
3)  Rupture life
断裂寿命
1.
The effects of temperature and applied stress on rupture life, and the relations of temperature, applied stress and rupture life to characteristic dimensions of coherent phases (γ matrix channel width and rafted γ precipitate thickness), and to the elongation as well as to the cross sectional area reduction of the tested specimens were investigated.
在 760-1050℃和780-115 MPa范围内,选择不同温度和应力配合进行了持久拉伸实验,研究了温度和应力的变化对试件断裂寿命的影响以及温度、应力和断裂寿命与共格相特征尺寸(基体相γ水平通道宽度、筏形析出相γ厚度)和试件延伸率及断面收缩率的关系。
2.
The P92 steel is a steel sort being used for main steam pipelines of ultra-supercritical units at present,its creep rupture life has widely drawn close attention.
P92钢是目前超超临界机组主蒸汽管道的应用钢种,其蠕变断裂寿命被广泛关注。
4)  life diagnosis
寿命诊断
1.
,and combining the features in China,the theory system on life diagnosis is put forward for the important hydraulic engineerings.
针对重大水利水电工程中存在的严重隐患缺陷或丧失功能,吸收美国等对此处理的先进理论和方法,并结合我国的特点,构建了重大水利水电工程寿命诊断的理论体系,并提出了水利水电工程生存寿命的原则,即安全原则、工程效益原则以及生态环境原则。
2.
The measures that life diagnosis of reheater by the thickness-detecting technology for oxide-scale on inner-side of tube, the increase of tube temperature detecting p.
结合莱城电厂2号锅炉末级再热器超温爆管实例介绍了采用内壁氧化皮测厚技术进行再热器寿命诊断、增加管屏壁温测点及开发壁温监测系统的处理措施。
5)  burn out life
烧断寿命
6)  switch life
开关寿命
1.
According to the detecting conditions about the switch life of the fluorescent light and ballast based on our National Standards and the Profession Standards for Railway Ministry, the paper proposes an instrument to detect the switch life of the fluorescent light and ballast as well.
根据国家标准和部标准对荧光灯及镇流器开关寿命的测试条件,提出了一种对荧光灯及镇流器开关寿命进行检测的仪器,介绍了其组成和工作原理,并给出了电路图。