1)  directly buried heating pipeline system
直埋热力管网
2)  direct burying
直埋
1.
According to its direct burying technology theoretical analysis is made and related design and construction methods are proposed.
介绍了聚氨酯保温直埋管道的两种敷设方式 ,就其敷设技术进行了理论分析 ,从管道的埋设深度、接头的处理等方面 ,提出了直埋聚氨酯管道的设计和施工要
3)  direct-buried
直埋
1.
Stress analyses for direct-buried heating pipe elbows;
直埋供热管道弯头的壳体应力分析
4)  directly buried
直埋
1.
Design of directly buried installation of steam pipe;
集中供热管网中直埋蒸汽管道的设计
2.
The failure of directly buried heat-supply pipeline is discussed, and the design essentials are put forward in accordance with local buckling and ovalization deformation.
探讨了直埋供热管道的失效,针对局部失稳和椭圆化变形,提出了设计要点。
3.
The object studied in this paper "directly buried innerresistance heat-preservation pipeline" is a new kind of directlyburied heat pipeline.
本文的研究对象“内阻式直埋保温供热管道”是一种新型的直埋保温供热管道,其保温结构既不同于传统直埋供热管道,也不同于目前国内外较多使用的“钢套钢”直埋保温技术。
5)  complete bearing spiral case
直埋蜗壳
1.
In order to study the stressing characteristic of spiral case structure with different embedding types and to ascertain the application feasibility in large-scale hydropower station powerhouse,the spiral case embedded with cushion layer and the complete bearing spiral case were analyzed using three-dimensional nonlinear finite element method(FEM) from an actual project.
结合某工程实例,对垫层蜗壳和直埋蜗壳进行了三维非线性有限元计算,重点从蜗壳外围混凝土裂缝的开展宽度和范围及机墩结构的不均匀上抬位移两方面,对两种埋设方式蜗壳结构进行了比较。
2.
By means of the ABAQUS software,a nonlinear finite element method(FEM) based on damage theory was used in structural calculations of the complete bearing spiral case of a large-scale hydropower station.
基于损伤理论,采用ABAQUS程序对某大型水电站直埋蜗壳方案进行非线性有限元计算,实现了蜗壳加载过程及超载的数值仿真,研究了此新型结构在内水压力上升的过程中钢蜗壳和钢筋应力、混凝土开裂区和机墩上抬位移的变化规律以及结构的超载能力。
6)  direct embedding
直埋方案
1.
Research for direct embedding scheme of spiral case of TGP power station on right bank;
三峡右岸电站蜗壳直埋方案研究
参考词条
补充资料:热力网
      供热管道的总称。热力网是因集中供热而形成的供热管道的集合。它是热电厂和中央锅炉房的配套系统。热力网按载热工质种类可分为蒸汽热网和水热网;按载热工质本身是否被利用又可分为开式热网和闭式热网。因生产用户常要求蒸汽直接参与生产过程,故蒸汽热网大多是开式的。水热网则有开式和闭式之分。当水热网对用户供应生产和生活用水时为开式;只供应采暖和通风热负荷时为闭式。供热管道可采用地上敷设(架空管道)或地下敷设(地下管道)。城区多采用地下敷设,工业区可考虑地上敷设。供热管道须考虑保温、热膨胀补偿、运行检修便利和防腐等问题。
  
  热力网的规模与热电厂(或中央锅炉房)的位置、供热区的范围、热负荷的种类及规模、管网布置方式、地面和地下建筑设施的情况等都有密切关系。水热网的输送距离可达30公里,比蒸汽热网大得多。因此,大范围的供暖多采用水热网。
  

说明:补充资料仅用于学习参考,请勿用于其它任何用途。