说明:双击或选中下面任意单词,将显示该词的音标、读音、翻译等;选中中文或多个词,将显示翻译。
您的位置:首页 -> 词典 -> 厂用系统
1)  auxiliary power supply system
厂用系统
1.
Several design improvements on secondary line of 6 kV auxiliary power supply system for large generator units;
大机组6 kV厂用系统二次线设计改进
2)  electric auxiliary system
厂用电系统
1.
The electric auxiliary system usually consists of condenser motor loads,and the starting of inductor motors can cause the problem of bus voltage fluctuations.
厂用电系统中一般带有集中电动机负荷,异步电动机启动会引起母线电压严重的波动。
2.
Through the power flow calculation and theoretical analysis for the electric auxiliary system using reactive power compensation,the economics benefit of the power plant was diseussed,and proved the project is feasible.
通过对发电厂的厂用电系统加入无功补偿后简单的潮流计算和理论分析 ,论述了在提高发电厂经济效益方面的作用 ,证明无功补偿方案的可行性。
3.
The electric auxiliary system sometimes has condenser motor loads,and the sta.
厂用电系统中一般带有集中电动机负荷,异步电动机启动会引起母线电压严重的波动。
3)  station service system
厂用电系统
1.
Improvement on treatment of single-phase earth faults in 6 kV station service system;
6kV厂用电系统单相接地故障处理方法的改进
2.
Novel neutral point treatment for power station service system;
发电厂厂用电系统中性点接地的新方法
3.
The main protection scheme of longitudinal differential relays collocated in the station service system,including high- voltage station transformer,series reactor,bus,short-distance transmission line,high-voltage alternating motor,etc.
论述了厂用电系统中高压厂用变压器、串联电抗器、母线、短引线、高压交流电动机等电力设 备配置纵联电流差动继电器作为主保护的方案,指出了各设备和对应的差动配置方案的特点、应用 中存在的特殊问题和整定计算中的影响因素,推荐了整定值。
4)  auxiliary supply system
厂用电系统
1.
This paper illustrates kinds of automatic transfer mode in auxiliary supply system, and explains the whole transfer period in detail, then concludes the importance and necessity of selecting high speed transfer in auxiliary supply system.
详细阐述了厂用电系统的各种切换模式及对切换全过程进行了细致的分析,通过比较,阐述了快速切换在厂用电系统切换中的必要性。
2.
In station, neutral grounding modes of high voltage auxiliary supply system have isolated neutral、 grounding by resistance and grounding by arc- suppression coil, each mode has different excellence and defect.
发电厂高压厂用电系统中性点接地方式有不接地、经消弧线圈接地和经电阻接地等,各种方式各有其优缺点。
5)  auxiliary power
厂用电系统
1.
Through analysis on the ferromagnetic resonance phenomenon in auxiliary power system of the nuclear power station, the possibility of the circuit resonance of the generator voltage is discussed.
通过发生在核电站厂用电系统的一起铁磁谐振现象的分析和处理,探讨了防治措施和方法。
2.
Two misoperations may cause generator energization fault:the improper close of generator -transformer circuit breaker and that of auxiliary power transformer branch circuit breaker.
发电机误上电故障有2种发生形式:一种是由发电机组的主开关误合闸引起,另一种是由厂用电系统开关误合闸引起。
6)  auxiliary power system
厂用电系统
1.
Design characteristics of the auxiliary power system of 1000MW unit;
1000MW机组厂用电系统的设计特点
2.
Modification and techno-economic analysis on auxiliary power system for Liuxihe Hydropower Plant;
流溪河水电厂厂用电系统的改造与技术经济分析
3.
The system configuration and major design principles of the main elecfrical wiring,generation system,auxiliary power system,and facility arrangement of the 2 1 000 MW USC units of Yuhuan Power Plant are briefly introduced,which provides reference for future optimization of USC unit electric system design.
文章简要介绍了玉环电厂2台1 000 MW超超临界机组的电气主接线、发电系统、厂用电系统、设备布置等系统配置和主要设计原则,供今后超超临界机组电气系统设计的进一步优化作参考。
补充资料:核电厂厂用电系统


核电厂厂用电系统
house supply of nuclear power plant

hed一anehong ehongyongd一on xltong核电厂厂用电系统(house supply of nuclearpower plant)核电厂运行及反应堆关停和事故情况下所需的电源系统。核电厂对厂用电要求很高,通常需要有两路以上的外界电源,而且彼此应是相互独立的和实体分隔的,以尽可能降低同一故障引起两路电源同时断电的概率。当核电厂发电机经主变压器与电网高压翰电线连接时,一路电源从发电机和主变压器之间引出,作为本厂的正常厂用电电源.该路电源,当发电机停运时,由电网供电,并将发电机隔离。另有一路电网电源供厂用电用.作为正常厂用电撅的备用电源。 两路厂用电源分别接到数段中压厂用母线上。正常运行时厂用电可由本厂发电机组和备用电源(见图)供给。当正常电源失电时会自动切换到备用电源。为了确保核电厂的安全,另外还设t至少两段安全母线。核电厂专设安全设施以及其他有关设施的用电设备都接在此安全母线上,使核电厂在严重事故状态下能安全停堆并维持在停堆冷却状态,以尽可能降低放射性物质外逸影响周围环境。┌─┐│ │└─┘3即V朋OV 核电厂厂用电主接线图 当核电厂失去外界电源井主汽门关闭后,反应堆仍在不断地释放衰变热,所以必须提供安全母线电想,使在全厂失去厂外电源时仍能保持反应堆的冷却。因此,核电厂设里了应急柴油发电机组.每一安全母线上均连接一台应急柴油发电机组作为应急电源,有的电厂另设一台柴油发电机组作为非安全级替代交流电源,作为全厂断电时的应急电源。 设里应急柴油发电机组是保证核电厂安全的非常重要的措施之一。它包括全套发电机组及其辅助设施以及专用的嫩料供应系统。它应能保证随时迅速起动,并在很短时间内带负荷.应急柴油发电机组在供电前,安全母线上的负荷应先自动切除,并按照所要求的程序起动有关设备.因此在选择柴油发电机组时,除了能保证迅速起动并带负荷外,还必须考虑起动时和带负荷时的时间顺序要求及其阶跃加载性能,并要保证在突加或突卸负荷时的瞬变影响,不使柴油发电机组的电压和频率变化达到不允许的数值。 非安全级替代交流电源用于应付全厂断电(station blaekout),即失去外界电源、同时汽轮机跳闸、并且厂内应急电源又不可利用的情况.在全厂断电期间,电厂应有能力保持反应堆堆芯冷却和安全壳完整性。非安全级替代交流电撅应有能力在全厂断电开始时即起动,并使所有的必要设备工作来应付全厂断电。它是一个独立的系统,可以手动连接到一个或全部冗余的安全母线上,其功率一般小于应急柴油发电机组,其性能要求可低于应急柴油发电机组。 核电厂的各种监侧仪表、控制、信号和开关操作等都配备有各种直流电源。它们均采用冗余配置,每一冗余电路至少包含一组蓄电他、一个蓄电池充电器和配电设施。在正常运行期间,蓄电池以浮充电方式运行。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条