3) Peterson earth coil
彼得森接地[消弧电抗]线圈,消弧线圈
5) compensated distribution network
经消弧线圈接地系统
1.
Study on fault feeder detection for single-phase-to-earth fault in compensated distribution network;
经消弧线圈接地系统单相接地故障选线研究
6) network grounded with arc extinguishing coil
消弧线圈接地系统
1.
Research on fault line selection in network grounded with arc extinguishing coil
消弧线圈接地系统的单相接地选线研究
2.
With the urban power distribution system in Chongqing, some experimental studies on fault line selection in network grounded with arc extinguishing coil are got on.
该接地选线装置在理论上克服了以往接地选线装置不能在过补偿方式下的消弧线圈接地系统进行有效选线的缺陷,使用了一种新的方法来检测单相接地故障瞬间零序电流和零序电压的瞬时相位,依据故障瞬间零序电流和零序电压的瞬时相位变化判断出接地故障线路。
3.
In order to cope with the problem of fault line selection in network grounded with arc extinguishing coil,a technique of fault line selection presented in literature[4] is exhibited.
就消弧线圈接地系统的接地选线问题,论文进行了详尽的分析和研究,特别是推出了文献[4]提出的单相接地选线方法,该方法采用瞬变信号正弦逼近方法求取线路零序电流的瞬时幅值和瞬时初相位,实现了基于单相接地瞬间暂态特征的接地选线原理和基于消弧线圈补偿特征的接地选线原理,其选线适应性强和选线准确率高,是一种在原理上和实现方法上都理想的消弧线圈接地系统接地选线方法。
补充资料:消弧线圈接地系统
消弧线圈接地系统
arc suppression coil grounded system
火旧ohtJX一or〕q飞万of、){ed(X(tong消弧线圈接地系统(are suPpression eoilgrounded system)见亦有效接地系统。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条