1.
Cause analysis of external corrosion on low temperature reheater of boiler;
锅炉低温再热器烟侧管壁腐蚀原因分析
2.
The leakage and defects of heating surfaces of the water wall,double-tube superheater,economizer,and low temperature reheater of the four 1 025 t/h boilers of a power plant are analyzed comprehensively.
对某火电厂4台1 025 t/h锅炉的水冷壁、包覆过热器、省煤器、低温再热器等受热面的泄漏及暴露的缺陷进行了综合分析,针对造成泄漏的主要原因,研究从根本上治理锅炉四管泄漏问题的对策。
3.
A comprehensive performance test was made for low temperature reheater of St45.
针对用于低温再热器的S t45。
3)  high-temperature reheater
高温再热器
1.
To aim at serious problems such as pipe overheating,rapid velocity of oxidation,pipes deformation which exist in high-temperature reheater of No.
针对秦皇岛发电有限责任公司1号锅炉高温再热器存在的管壁超温、氧化速率快、管排变形严重等问题,从运行参数比较、管材金相组织分析、机械性能试验、氧化皮厚度测量等方面进行了分析,进行改进后避免了再热器管子超温运行,降低了氧化速率,减缓了寿命损耗。
4)  high temperature reheater
高温再热器
1.
Cause analysis of the high temperature reheater blast at No.2 boiler in Ningxia Zhongning Power Generation Co., Ltd.;
宁夏中宁发电有限公司~#2炉高温再热器爆管原因分析
2.
4-YM4 boiler high temperature reheater installation technics from combination scheme, welding procedure and heat treatment technics.
4-YM4锅炉的高温再热器安装工艺进行总结,介绍如何在保证施工质量的前提下减短工期,加快生产进度。
3.
According to the problems of corner joint leakage of high temperature reheater header in 6th boiler of Matou Power Plant,after the causes are founded through system dynamic testing and checking of original design operation situation from the aspets of design,structure mechanics andoperation,the high temperature reheater is retrofitted,and the effect is well.
针对马头发电厂6号锅炉高温再热器联箱管排角焊缝频繁泄漏现象,通过对系统动态测试,并从设计、结构、力学、运行等方面对原设计工况进行复核计算,找出症结后,对高温再热器系统进行改造,改造后效果良好。
5)  low-temperature reheater
低温再热器
1.
Wear treatment for low-temperature reheater pipes of M417A boiler;
M417A型锅炉低温再热器管磨损处理
2.
High hat like sealing structures are adopted for the low-temperature reheater roof-passing tubes of boiler No.
黄埔发电厂5号炉低温再热器穿炉顶管处采用高冠状密封结构,运行中出现因密封焊缝裂纹而导致爆管事故。
3.
Through macroscopic examination and microstructure analysis, the causes leading to tube-burst in low-temperature reheater of a 1021 t/h boiler during operation in a period less than one year have been analysed, and disposal measures being put foreard.
通过宏观检查与显微组织分析,分析了某电厂1021t/h锅炉运行不足1年低温过热器爆管泄漏产生的原因,认为人孔门保温不严,造成人孔门附近管排局部发生严重飞灰磨损,是导致低温再热器爆管的主要原因,对此,提出了相应的处理措施。
6)  tube wall temperature of reheater
再热器壁温
1.
By the analogy calculation, the factors that result in the change of temperature during the phrase are analyzed, and the dependence and the law between these factors and the tube wall temperature of reheater.
在借鉴稳定工况再热器壁温计算模型的基础上,针对单元机组启动阶段特点推导出适用于该工况下壁温的计算模型,通过模拟计算讨论了启动阶段影响各段再热器壁温的因素,获得了这些因素与壁温间的关系曲线及变化规律,提出了相应阶段预防超温的一些有效措施。
补充资料:摆动式燃烧器调温


摆动式燃烧器调温
steam temperature control by tilting burner

bo一dongsh{ranshaoqlt旧owen摆动式瀚烧器调通(steam temperature con-trol by tilting burner)调整嫩烧器的倾角以改变火焰中心位!,借以改变炉膛出口烟温来实现汽温调节的方法。一般多用于切向燃烧的燃煤锅炉中。嫩烧器上下摆动200~300时,炉膛出口烟温变化约110~140℃,汽温调节幅度30~4。℃。此种调温方法,主要用于再热汽温的调节,但燃烧器倾角改变时对过热汽温亦有明显影响。当燃烧器上下摆动时,对靠近炉膛出口的受热面的换热温差影响较大,其吸热量变化也较大,因此应将被调对象的受热面(再热器或过热器)布t在炉膛出口附近,可以获得明显的调温效果。 对于低灰熔点燃料,为了防止结渣,其调温幅度应加限制.对于挥发分甚低的嫩料,不宜采用此种调温方式。 在嫩油锅炉中,由于火焰较短,摆动燃烧器对炉膛出口烟气温度影响较小,调温效果不明显,故一般不采用。 摆动式燃烧器调温方式调节灵敏,不需增加附加受热面和功率消耗,是调节再热汽温用得较多的手段之一。