说明:双击或选中下面任意单词,将显示该词的音标、读音、翻译等;选中中文或多个词,将显示翻译。
您的位置:首页 -> 词典 -> 配电系统恢复
1)  distribution system service restoration
配电系统恢复
2)  power system restoration
电力系统恢复
1.
Application of PN algorithm to power system restoration;
Petri Nets算法在电力系统恢复中的应用
2.
In recent years,power industries around the globe have been undertaking an in-depth restructuring,which leads to some new challenges to the problem of power system restoration.
电力工业的市场化改革对电力系统恢复问题具有一定的影响。
3.
In order to analyze all the factors in the problem of power system restoration(PSR) from a whole aspect and optimize the restoration process,this paper summarizes all kinds of issues relevant to PSR,which consist of not only the feature of primary system,but also the operator organization and auxiliary service of monitoring and control system.
为全面分析影响电力系统恢复过程的因素,分别从调度和运行机构、二次监控系统和一次系统3方面阐述影响恢复的诸多因素,提出系统恢复过程的整体模型。
3)  system restriking voltage
系统恢复电压
4)  restoration [英][,restə'reɪʃn]  [美]['rɛstə'reʃən]
系统恢复
1.
The analysis show that the protections and security equipments may work abnormally and the power system requirements may change during different steps of restoration.
对黑启动过程中系统运行特性的变化及其对继电保护和安全自动装置动作特性的影响进行了分析,指出在系统恢复的不同阶段中,由于运行条件发生极大变化,保护和安全自动装置的动作特性也可能随之发生变化,导致部分装置会误动或者不动,失去了原有的作用,甚至阻碍了系统的恢复,严重时将导致系统再次崩溃。
5)  system restoration
系统恢复
1.
Through analyzing and comparing many published papers associated with Petri net applications,a concise and systematic survey is made from several specific areas involved,including fault diagnosis,power system restoration,distribution network reconfiguration,unit commitment,power network topology analysis,reliability analysis,protective relay modeling and hybrid power systems.
通过收集和整理国内外相关学术期刊和会议论文集中已发表的数十篇有关Petri网在电力系统中应用研究方面的学术论文,按故障诊断、系统恢复、配电系统重构、机组组合、网络拓扑分析、可靠性分析、继电保护建模与混杂电力系统分析等方面分别进行了分类述评。
2.
Combining general technological methods the paper mainly probes into several techniques of system restoration in applicable to LAN.
现在通过一定的软硬件管理保护手段可以大大减少管理员工作量,结合常见的技术方法,探讨了几种适宜在局域网中使用的系统恢复技术。
3.
This paper investigates several specific system restoration cases of foreign power systems and the experience gained from them, which will help other utilities to develop restoration schedules.
电网发生部分乃至全部停电事故后 ,系统恢复目标是在尽可能短的时间内对尽可能多的负荷恢复供电。
6)  System recovery
系统恢复
1.
The main contributions of this paper are(1) presenting the method to represent service core based on component families and installation orders,which can precisely capture the system services perceived by users;(2) proposing the reasoning rules of system recovery based on component compatibility .
从基于构件的系统在面临各种不同的恶意攻击、系统故障和意外事故时,根据预先定义好的生存性规范为用户提供不同等级的系统服务出发,研究了构件系统恢复中的一些关键问题。
2.
Through practicing and analyzing traditional system recovery methods, we find that GHOST software can solve problems quickly and conveniently.
网络机房常因操作不当、系统崩溃、病毒破坏而需恢复系统,通过实践与分析传统的系统恢复方法,发现利用Ghost软件可以快捷方便地解决所遇到的问题,从而提高网络机房的管理效率。
3.
This paper proposes a mechanism of intrusion evidence audit and system recovery in open systems -Eudemon.
该文提出了一种开放式系统的攻击取证和系统恢复机制Eudemon。
补充资料:低压配电系统接地型式


低压配电系统接地型式
earthing system of low-voltage network

d lyo Pe,dlonx,tong Jledl xlngsh}低压配电系统接地型式(earthing system oflow一voltage network)低压交流220/3sov配电系统采用的接地型式。依据低压配电系统(见低压配电)的对地关系、电气设备(或装置)的外露可导电部分的对地关系以及整个系统的中性线与保护线的组合情况,低压配电系统接地型式有TN系统(包括TN-S、TN一C一S、 TN一C系统)、TT系统和IT系统,共五种(见图)。第一个字母:T表示一点直接接地;I表示所有带电部分与大地绝缘或经人工中性点接地。第二个字母:T表示外露可导电部分与大地有直接的电气连接,而与低压配电系统的任何接地点无关;N表示外露可导电部分与低压配电系统的接地点(通常为中性点)有直接的电气连接。第二个字母后面的字母:S表示整个系统的中性线和保护线是分开的;C表示整个系统的中性线和保护线是共用的;C一S表示系统中有一部分中性线与保护线是共用的。 根据低压配电系统中,防止因电气设备绝缘损坏引起人体触电事故原理的不同,可将这五种接地型式分为两类。一类是当人们接触到绝缘损坏的电气设备外壳时,使通过人体的电流在安全容许范围之内。这类接地型式有电源中性点对地绝缘(或经高电阻接地)、电气设备外壳直接接地的IT系统和电源中性点直接接地、电气设备外壳也独立直接接地的TT系统。这两种系统都要求电气设备的接地电阻很小,从而使故障设备对地电压不超过50V,在人体电阻比接地电阻大得很多的条件下,就可以满足上述电流值的要求,起到保护作用。另一类是将电气设备外壳用保护线与中性点直接接地的电源的接地装里相连。当设备绝缘损坏时,由电源相线~故障设备外壳~保护线~电源中性点形成回路,较大的短路电流起动装设于电源侧的保护电器,从而将故障设备从系统中切除,以起到保护作用。TN系统便属于这种类型。 IT系统电源中性点对地绝缘(或经大于或等于IO00Q电阻接地),电气设备的外露可导电部分直接接地的系统。当电气设备绝缘破损时,由非故障相对地流人电容电流,由于设备外壳对地电压限制在安全值50V以下,电容电流很小,允许短时间不切断电源,但这时中性点的对地电位升高至相电压,如引出中性线,而被人触及是有危险的,所以这种系统不宜引出中性线,无法对单相设备及照明供电。此外,考虑到低压配电系统夜盖范围很大,而所有电源均长期维持为中性点对地绝缘状态是困难的,且单相、间歇性电弧接地还这类系统消除了人为事故,PE线不通过负荷电流,所以系统正常工作时,不像TN一C系统中PEN线那样,带有电位。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条