1) Resistive leakage current of MOA
避雷器阻性泄漏电流
2) leakage current of arrester
避雷器的泄漏电流
3) resistive leakage current
阻性泄漏电流
1.
It is important to monitor the state of Metal-Oxide Arresters (MOA) on line, especially the resistive leakage current, which reflects the MOA s health to a great extent.
由于阻性泄漏电流很大程度上能反映氧化锌避雷器的健康状况,因此在线监测阻性泄漏电流尤为重要,分析比较了MOA的几种在线监测方法及几种测量方法存在的问题,指出了两种影响测量精度,但未引起重视的干扰源,并对近些年国内外此方向的发展动态和未来的发展趋势加以综述。
2.
In this paper, simulation is made to show the effect on the eigenvector and resistive leakage current under interharmonics of different frequency.
阻性泄漏电流基波和3次分量是反映MOA劣化现象的两个故障特征量,仿真分析对此问题及间谐波电压对阻性泄漏电流的影响。
3.
It is important to monitor the state of Metal-Oxide Arresters (MOA) on-line ,especially the resistive leakage current, which reflects the MOA s health to great degree.
由于阻性泄漏电流很大程度上能反映氧化锌避雷器的健康状况,因此在线监测阻性泄漏电流尤为重要,分析比较了MOA的几种在线监测方法及几种测量方法存在的问题,指出了两种影响测量精度,但未引起重视的干扰源。
4) bleed resistor
泄漏电阻器
6) non-linear-resistor-type arrester
非线性电阻器型避雷器
补充资料:泄漏电流
分子式:
CAS号:
性质:沿不希望的绝缘途径流过的电流。泄漏电流由泄漏电流试验测定。泄漏电流试验一般是直流泄漏电流试验。泄漏电流试验可发现绝缘物的硬伤、脆裂等缺陷。发电机、交流电动机、变压器和电抗器、油断路器和空气断路器、电力电缆、避雷器等高压设备投入运行前应按规定做泄漏电流试验。绝缘手套、绝缘靴、绝缘垫等电工安全用具亦应按规定,定期做泄漏电流试验。
CAS号:
性质:沿不希望的绝缘途径流过的电流。泄漏电流由泄漏电流试验测定。泄漏电流试验一般是直流泄漏电流试验。泄漏电流试验可发现绝缘物的硬伤、脆裂等缺陷。发电机、交流电动机、变压器和电抗器、油断路器和空气断路器、电力电缆、避雷器等高压设备投入运行前应按规定做泄漏电流试验。绝缘手套、绝缘靴、绝缘垫等电工安全用具亦应按规定,定期做泄漏电流试验。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。