说明:双击或选中下面任意单词,将显示该词的音标、读音、翻译等;选中中文或多个词,将显示翻译。
您的位置:首页 -> 词典 -> 自适应重合闸装置
1)  self-adapting automatic recloser
自适应重合闸装置
1.
In order to avoid 500kV Sichuan Hong-Long double-circuit lines on same tower tripping simultaneously because of out-phase instantaneous fault and to enhance the reliability of power supply, a new relay protection and self-adapting automatic recloser of double-circuit lines on same tower has been developed.
为避免四川电网洪龙 5 0 0kV同塔双回输电线路因异名相瞬时故障而同时跳开 ,增大系统供电的可靠性 ,研制出新型的同塔双回输电线路继电保护及自适应重合闸装置 ,并对其进行了RTDS实时仿真试验。
2)  adaptive reclosure
自适应重合闸
1.
The adaptive reclosure of double circuit lines on the same tower and its field test technology are introduced.
介绍了同杆双回线自适应重合闸及其现场测试技术,提出了多种试验方法,分析和解决了试验中发现的问题。
2.
Aiming at the limitation of traditional adaptive reclosure,a neural network-based method has been proposed and a three-layer BP neural network has been designed.
针对传统自适应重合闸存在的缺陷,提出了基于人工神经网络的自适应重合闸方法,并设计了一个3层BP神经网络,利用EMTP进行仿真计算,仿真结果表明,该网络具有较好的识别性能。
3.
A novel method of identifying permanent fault for single-phase adaptive reclosure in transmission lines with shunt reactors is proposed.
针对带并联电抗器的超高压输电线路,提出一种单相自适应重合闸永久性故障识别的新方法。
3)  adaptive reclosing
自适应重合闸
1.
Single-phase adaptive reclosing based on phase angle of fault
基于故障相相角的单相自适应重合闸
2.
Through the comprehension of information on double circuit lines, criterion for unserious permanent fault, auxiliary criterion and principle for reclosing according to phase order are combined perfectly, which realize the function of adaptive reclosing on double circuit lines on the same tower, and raise the power system stability in the maximum limit.
500kV同杆双回线在电力系统中具有举足轻重的作用,该项目通过综合两回线信息,将非严重永久故障判据、辅助判据以及按相顺序重合原则完美地结合起来,实现了同杆双回线的自适应重合闸功能,从而最大限度地提高了电力系统的稳定性。
3.
This paper provides a new idea and approach for adaptive reclosing in traction supply system.
根据现代控制技术中电力系统继电保护的要求 ,把人工神经网络理论应用于自适应单相重合闸中 ,并分析了原理实现的可行性 ,为牵引供电系统中自适应重合闸提供了一条新的思路和途
4)  self-adaptive reclosure
自适应重合闸
1.
Virtual technology of self-adaptive reclosures for transmission lines;
输电线路自适应重合闸的虚拟技术
2.
We proposed the self-adaptive reclosure with the Bergeron model for UHV long transmission lines.
实现自适应重合闸的方法已经很多,但是将输电线贝瑞隆模型应用其中的,国内外还没有见到,因此提出了基于贝瑞隆模型的特高压长线路单相自适应重合闸的新原理。
5)  auto-reclosing device
自动重合闸装置
1.
Measures of using automatic stand-by power switching devices and auto-reclosing devices with protection values reasonably set are proposed to solve th.
针对现有地区电网的接线方式和保护配置,比较全面地分析了110kV双电源变电站、线路-变压器组变电站、有电源上网的变电站在不同运行方式及故障方式下的运行可靠性,对运行实践中出现的问题,提出了采用备用电源自动投入装置、自动重合闸装置及合理设定保护定值等方法来解决的方案,该方案在惠州电网变电站运行的实践中得到验证。
6)  adaptive auto-reclosure
自适应自动重合闸
1.
Present achievements and prospects of adaptive auto-reclosure;
自适应自动重合闸现状与发展
补充资料:自适应自整定调节
分子式:
CAS号:

性质:在调节系统中,对象的动态特性往往是变化的,如果变化不大或调节的质量要求不高时,可以采用固定规律的调节器,假若变化大,质量要求又高时,需要选择可变规律调节器。调节器参数的改变是直接按照对象特性的变化进行的,叫作自适应调节。对象的识别和调节器的规律的计算都用一个计算装置进行,就叫自适应自整定调节,或简称自整定调节。 

说明:补充资料仅用于学习参考,请勿用于其它任何用途。