说明:双击或选中下面任意单词,将显示该词的音标、读音、翻译等;选中中文或多个词,将显示翻译。
您的位置:首页 -> 词典 -> 隔爆型干式变压器
1)  flameproof dry-type transformer
隔爆型干式变压器
1.
This paper analyzes the heat transfer process and some features of flameproof dry-type transformer, establishes its dynamic temperature rise prediction model based on nonlinear mapping ability of artificial neural network, and also verifies its feasibilities and advantages through comparing calculating result with test result.
分析了大容量隔爆型干式变压器热传递过程和特点 ,利用人工神经网络的非线性映射能力建立了其动态温升预测模型 ,并将计算结果和实测结果作了比较 ,验证了其可行性和优越
2)  mining flameproof dry type transformer
矿用隔爆型干式变压器
1.
The performance parameter of mining flameproof dry type transformers are adjusted in newly implementing standard,the academic analysis and calculation of short circuit impedance for transformer are processed.
根据新实施标准对隔爆型干式变压器性能参数进行调整,对其变压器的短路阻抗进行了理论分析和计算,并给出了矿用隔爆型干式变压器的短路阻抗值。
3)  Mining Flameproof Dry-type transformer
矿用隔爆干式变压器
4)  dried explosion-proof transformer
干式防爆变压器
5)  FLP drill transformer
隔爆变压器
6)  flameproof mining transformer
矿用隔爆变压器
补充资料:干式变压器
      铁心和绕组都不浸在绝缘油中的变压器。一般用于安全防火要求较高的场合,如高层建筑的屋内变电所,地下铁道与矿井变压装置等。铁心结构与油浸式基本相同。线圈结构在容量为315千伏安以下时为圆筒式;315千伏安以上时, 高压线圈为连续式,低压线圈为螺旋式或双饼式。
  
  干式变压器有下列3种类型。
  
  ①开启式:变压器身与大气相通。由于空气的绝缘强度和散热性能都比油差,故以空气为绝缘的干式变压器,其材料消耗要比油浸式为多。干式变压器一般都采取自冷式,对于较大的干式变压器,为加强散热效果也有用强迫风冷式的。这种干式电力变压器用在地下铁道、公共建筑物及车间内部等环境比较干燥清洁而防火要求较高的场所。
  
  ②封闭式:用在与外部大气不相通,环境恶劣的地方。由于密封后散热条件差,所以主要用于矿井(见矿用变压器)。
  
  ③浇注式:用浇注的环氧树脂作为绝缘介质和散热媒介。这种变压器结构简单、体积小、重量轻,主要用作小容量配电变压器。
  

说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条