1) hydraulic alarm valve
湿式报警阀
1.
Some problems existing in the design and commissioning of automatic sprinkling system of Yinqiao Building was summed up, including startup of the main spray pump, pressure control of pipe network, and type selection of hydraulic alarm valve.
总结了上海银桥大厦自动喷淋系统设计及调试中存在的一些问题,如喷淋主泵的启动方式、管网压力的控制及湿式报警阀的选型等,并给出了解决方法。
2) wet system alarm valves
湿式报警阀组
3) divided seat ring type alarm valve
分座环式报警阀
4) alarm valve
报警阀
1.
The feasibility analysis of the substitute program of wet alarm valve group;
湿式报警阀组替代方案的可行性分析
2.
The initial fire water requirement, booster pump control, water supply safety of alarm valve and boosting facilities of high-rise buildings in design of sprinkler system since the issuance and implementation of "Code of Design for Sprinkler Systems"(GB 50084-2001) were discussed.
对《自动喷水灭火系统设计规范》(GB5 0 0 84— 2 0 0 1 )颁布实施以来 ,自动喷水灭火系统设计中初期消防供水量、增压泵控制、报警阀的供水安全性以及超高建筑的增压设施等问题进行了探讨。
5) alarm valve
警报阀
6) waterpower alarm valve
水力报警阀
1.
Discussion on settlement of waterpower alarm valve of automatic spraying fire-controlling system;
浅谈自动喷淋灭火系统中水力报警阀的设置
补充资料:溢流阀、顺序阀、减压阀的比较
溢流阀 | 减压阀 | 顺序阀 | ||
控制油路的特点 | 通过调整弹簧的压力控制进油路的压力,保证进口压力恒定,p2=0 | 通过调整弹簧的压力控制出油口的压力,保证出口压力p2稳定 | 直控式-通过调定调压弹簧的压力控制进油路压力;夜控式-由单独油路控制压力 | |
出油口情况 | 出油口与油箱相连 | 出油口与减压回路相连 | 出油口与工作回路相连 | |
泄漏形式 | 内泄式 | 外泄式 | 内泄式 | |
进油口状态及压力值 | 常态 | 常闭(原始状态) | 常开(原始状态) | 常闭(原始状态) |
工作状态 | 进出油口相通,进油口压力为调整压力 | 进油口压力低于出油口压力,出油口压力稳定在调定值上 | 进出油口相通,进油口压力允许继续升高 | |
联接方式 | 并联 | 串联 | 实现顺序动作式串联作卸荷阀用时并联 | |
功用 | 定压、溢流或安全作用限压、稳压、保压 | 减压、稳压 | 不控制系统的压力,只利用系统的压力变化控制油路的通断 | |
进油腔压力p1控制阀芯移动 | 出油腔压力p2控制阀芯移动 | 进油腔压力p1控制阀芯移动 |
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条