1) broken wire repairing
断线补修
2) disconnection
断线
1.
Elimination of TORSO coil curl disconnection fault of GE Signa1.5T nuclear magnetic resonance imaging system;
GE Signa 1.5T核磁共振TORSO线圈断线故障的修复探索
2.
Analysis on single-phase disconnection fault of a 110kV transmission line;
110kV输电线路单相断线故障分析
3.
As auxiliary function of protection,disconnection of voltage transformer hasn't been heeded enough.
电压互感器(TV)断线作为保护的辅助功能受到的重视程度往往不足。
3) broken line
断线
1.
The threshold ranges of grounding and broken 10 kV line faults are given for proper distinguishing the grounding line fault from the broken line fault.
根据实际测量值最终确定了系统的报警阈值,尤其给出了10kV线路接地和断线(或剪断)故障的阈值范围,以便正确地报出接地故障和断线故障。
2.
Three countermeasures are brought forward:discharge the recloser when the control loop appears broken line or the handle SPT is set local,make KTP reflect the actual state of circuit breaker.
结合整组试验,WXH-800系列线路保护装置的重合闸原理和电气设计图进行综合分析,发现WXH-800系列线路保护装置存在重合闸误动作的原因,提出了3种解决问题的方法,即控制回路断线时使重合闸放电、SPT把手就地时使重合闸放电、给KTP正名,并对每种方法的利弊进行了比较。
3.
The paper introduced the condition of broken line fault on 500 kV Shen-Hou No.
介绍了500kV神侯Ⅰ回线断线事故的情况,对事故情况进行了分析,得出事故的主要原因是导线压接质量存在严重隐患,针对事故原因,提出了整改措施,为今后新建线路的施工、验收、监理提供经验参考。
4) line breaking
断线
1.
Analysis of complex line breaking and grounding fault in the power system with neutral point indirectly grounded;
小电流接地系统单相断线加接地故障的分析
2.
Analysis of the performances of the impedance relay for phase to phase protection on line breaking;
断线时相间保护阻抗继电器动作行为分析
3.
On boundry conditions,the article,with compound foreword net,analyses line breaking fault in undercurrent earthed system and obtains the voltage instructions and the insulation supervision installment movements in the breakdown situation.
用复合序网和边界条件对小电流接地系统线路断线故障进行了分析,得出故障情况下电压指示及绝缘监察装置动作情况,着重分析了单电源单回线路断线及相继金属性接地时的电压指示,为调度、运行人员分析判断提供一些参考。
5) breakage
断线
1.
The malfunctions include the uniphase breakage at the y/y 0 transformers primary coil,the uniphase performance of three phase asynchronous motor,and the zero conductors breakage in three phase four wire system,etc.
本文作者主要对配电系统中相线断线及三相四线制零线断线等故障进行了分析及采取的防范措施。
6) wire breakage
断线
1.
Cause and categories of wire breakage and its prevention in copper wire drawing;
铜线生产中断线原因、类型的分析和防范
2.
Origination of Wire Breakage in Ultra-fine Single Crystal Copper Wire Drawing and its Technical Improvement;
单晶铜超微细丝的断线分析及制备工艺
3.
It is easy to occur short-circuit and wire breakage whenever optical fiber composite overhead ground wires(OPGW)are ice- coated.
架空复合光缆(OPGW)覆冰后,更容易发生短路和断线,文章从OPGW光缆的材料特性和机械特性进行分析,找出了OPGW光缆易发生覆冰断线的主要原因是弹性模量小和熔点低,并针对OPGW光缆的这种特性提出了防范措施。
参考词条
补充资料:电力系统断线谐振过电压
电力系统断线谐振过电压
resonance overvoltage due to broken lines in electric power system
d一onl一xjtong duonx旧nx一ezhen guod一onyo电力系统断线谐振过电压(resonanceovervoltage due to broken lines in eleetrie Powersystem)电力系统中由于导线断落而激发起来的铁磁谐振过电压。图中所示为中性点不接地系统中单相断线和一侧导线落地所形成的典型谐振回路,其中云.、云b和云。为电源变压器的对称电动势,LK为空载变压器的励磁电感,C。和C12为导线的对地和相间电容。按照载维南定理,可将此图等效变换为最简单的申联电路,图中:一1·5:·,:一:。鲁,e一e。+Ze:2。两相断线时亦可变换为类似的等效电路。由于L为铁芯电感,故在不同C值(即不同导线长度)下可能发生高颇、工频和分频铁磁谐振,并在断线处和负载变压器端部产生铁磁谐振过电压。在工频谐振时,主回路呈现容性,亡。与电源电动势反相,负荷变压器三相电压的相序会与断线前相反,称为相序翻转。此时负载变压器二次侧如接有小容盘的电动机,将会发生反转。但当负载变压器二次侧的有功负荷较大时,其等效电阻可以吸收足够的振荡能量而使谐振强度受到抑制。了毛竺工不了飞乙K厂喜几.爵酷一十斗二阿、{牲一兰坚卜 相断线接线图及其等效电阻 断线谐振亦可在消弧线圈补偿电力系统和110~22okV的中性点有效接地的电力系统中产生,后者是由于部分负载变压器的中性点不接地而形成断线谐振回路。 断线谐振过电压引起的绝缘损坏在配电网中较常发生,引起配电变压器绝缘闪络和避雷器损坏等.实验表明,断线后的工频谐振往往具有自激性质,为此可在空载变压器的高压或低压侧投人一定大小的相间电容,以使自激谐振转化为他激性质,然后投人瞬间吸能装置加以抑制。最好的防止措施是加强线路维护,避免发生断线。此外,一旦发生断线,则尽快切除负载变压器,以缩短谐振的持续时间。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。