1) power supply lines
供配电线路
1.
A discussion is given of two characteristics of power supply lines and earthing system of experimental buildings.
本文通过对实验楼供配电线路及接地系统两方面特点的论述及对不同供电方案的比较,阐明了在电气设计过程中应注意的问题,以期找出一种较理想的电气设计方案。
2) distribution line protection
供配电线路保护
3) power supply line
供电线路
1.
Many years operating data showe that there are many weak links in existing insulation coordinating scheme of power supply lines of Nanyang Oilfield.
多年来的运行数据表明南阳油田供电线路现有的绝缘配合方案存在很多薄弱环节,在油田生产过程中经常发生线路闪络和开关跳闸事故。
2.
The way of reducing the loss of electric energy to its minimum was discussed from several paths such as reducing the loss of voltage in power supply line, selection of dissimilar line section according to the densities both of permissive current and economical current.
本文从减少供电线路的电压损失 ,按照允许电流和经济电流密度选择线路导线截面等几方面 ,分析探讨最大限度降低电能损失的途
3.
This paper analyzes the existing problems about the software of the power supply line design and the project preliminary budget at present.
本文分析了当前供电线路设计与工程概预算软件所存在的问题,提出了一种新的基于网络模式的,两者有效、完美地集成一体化的软件设计方法。
4) Line-Powered
线路供电
1.
Design of Embedded Line-Powered Hydrology Telemetric Terminal;
嵌入式线路供电水情遥测终端的设计
5) supply line
供电线路
1.
This paper analyses the effects of the single-phase break fault of the supply line on the generators at the small-sized hydropower station.
从理论上分析了小型电站供电线路单相断线故障对发电机的影响,讨论了单相断线时发电机电流的计算方法并附有算倒。
6) Distribution Line
配电线路
1.
Brief analysis the reasons caused loss and its countermeasures in forest area 10kV distribution line;
浅谈林区10 kV配电线路损失的原因及对策
2.
Study on line arrester applied to improve the lightning performance of 10 kV distribution lines
应用线路避雷器提高10kV配电线路防雷性能的研究
3.
In order to change non-normative status of setting of interim electro-equipment in construction local, this paper expounds how to set interim electro-equipment in construction local from aspects of construction design, laying distribution line, three class power distribution and two class leakage protection, earthing and lightning protection, distribution box, use and maintenance and so on.
为改变施工现场用电不规范的状况 ,从临时用电施工组织设计 ,配电线路的敷设 ,采用三级配电、二级漏电保护 ,接地与防雷 ,配电屏、配电箱、开关箱 ,使用与维护等方面阐述了施工现场临时用电的合理设
补充资料:电缆供油装置允许供油压力计算
电缆供油装置允许供油压力计算
calculation of the permissible pressure for cable oil feeding equipment
d旧nlan gongyou zhuangZh【yunXU gongyou yol一J,suon电缆供油装t允许供油压力计算(calculationof the permissible pressure for eable 011 feedingequipment)为使充油电缆的油压保持在允许范围内,根据电缆线路的最大和最小允许工作压力,对电缆线路在环境温度最高的夏季满载时供油装t的最大允许供油压力,和在环境温度最低的冬季不带电时供油装t的最小允许供油压力的计算.最大和最小允许供油压力.取决于电缆线路的长度、高差、负荷和环境沮度等因素。 如图所示为由压力供油箱(见充油电垅供油装!)在一端供油的充油电缆线路最大和最小允许供油压力分布情况.P叮mi。P X 10一2 ~尸“m‘。十nP’r一几人沪万不万万二气陪片l一一一一一一一一一一一一_一产尸一 终端头.|一|州|||人;点叠掩__支________--一丁----------一终瑞头压力箱 卜 屯电组旦老 电缆线路由压力供油箱在一端供油时的压力分布 静态压力计算在电缆线路的负荷不变时,电缆内部的油压为静态压力。 (1)在夏季满载时压力箱的供油压力最大,线路最低处B点的油压为线路上的最大静油压,此值要小于电缆的最大允许静油压,即式中尸PT。、。为压力箱的最小允许供油压力,MP。;h、为电缆线路最高处A点的高程,m;Pcsml。为电缆的最小允许静油压,MPa,其余符号的意义同式(l). 暂态压力计算在电缆线路的负荷变化时,电缆内部的电缆油因膨胀或收缩而产生的油流在油道内分别产生暂态压力升或暂态压力降,两者均简称为暂态压力。在油压变化的暂态过程中.作用在电缆上合成的瞬时压力为暂态发生前的静态压力与暂态压力升之和。 (”电缆负荷增加时,在电缆线路的最低处B点出现最大瞬时压力不得大于电缆的最大允许瞬时油压。暂态压力升的最大值出现在冬季电缆线路由不带负荷状态突然满载时,但此时B点的静态压力最小.最大静态压力是在夏季满载时,但在夏季接近满载时产生的暂态压力升并不是最大值。因此要正确计算静态压力和暂态压力升两者之和的瞬时压力的最大值是很复杂的,但可按图所示近似地把B点的最大静态压力与最大暂态压力升之和视为最大瞬时压力,于是压力箱的最大允许供油压力应满足下列条件 尸p,二,二△尸,一尸。T,~ ‘井锣终;十h。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条