说明:双击或选中下面任意单词,将显示该词的音标、读音、翻译等;选中中文或多个词,将显示翻译。
您的位置:首页 -> 词典 -> 全电压
1)  full-rated voltage
全电压
1.
The trigger characteristics of triggered spark gaps and of triggered vacuum switch are compared, and a synthetic making circuit at full-rated voltage is presented.
概括了断路器关合短路电流时由预燃弧阶段开始的物理过程,对比了触发火花间隙和真空触发开关用作快速关合装置时的触发特性,提出了一种在全电压条件下进行合成关合的试验回路。
2)  voltage security
电压安全
1.
Power system is now more and more vulnerable to voltage security problems, which are usually classified into two categories: transient and static voltage security, with the latter including static voltage stability and static voltage deviation.
电压安全问题严重威胁电力系统的安全运行。
2.
In the light of static voltage security in electricity market environment, an approach to calculate the risk of low voltage in power system is proposed.
针对电力市场环境下的静态电压安全问题,建立了一种电力系统低电压风险评估方法。
3.
One is static security assessment (SSA), the other is dynamic security assessment (DSA), and voltage security assessment (VSA) was included in SSA and DSA.
一直以来电力系统的安全性评估包括静态安全评估和动态安全评估,电压安全评估包含于这两大评估之内。
3)  safe voltage
安全电压
1.
In this paper, the authors give us definitions about safe voltage, ground-connecting current, touch voltage and step voltage in details and also make a conclusion that it is the necessity of ground-connecting protection to electrical equipment.
本文详细分析了人体的安全电压、接地电流和对地电压、接触电压和跨步电压, 论述了电气设备的接地保护必要性。
2.
The auto-reset power designed by this scheme can ensure the initial output voltage to remain 5V,which is in the safe voltage range.
利用此方案的开机自复位电源能够让开机初始输出电压始终保持在5V的安全电压范围内,同时也可提供5 ̄15V的工作电压,以确保实验的顺利开展,有效预防电子类实验系统的电源安全性问题。
4)  safety voltage
安全电压
5)  full voltage
满电压,全电压
6)  voltage security region
电压安全域
1.
Based on the sensitivities of the voltage stability index to node injections, a heuristic method for estimating the shortest radius of power system voltage security region in node injection space is proposed.
基于电压稳定量化指标对节点注入的灵敏度提出了一种估计注入空间中电压安全域最短半径的启发式方法,该方法以一定的步长逐步逼近注入空间中电压安全域的最近边界,可以考虑各种系统运行参数的约束,不存在数值收敛性问题。
补充资料:电力系统非全相运行过电压


电力系统非全相运行过电压
overvoltage in open phase operation in electric power system

  相开断的结果使得回路接近于谐振状态.如果TK<(C。+ZC::)/(C。+3C,:),且如乙>1/[。(C。+ZC::)〕,则单相开断后可能激发起工频铁磁谐振.这些情况都会在被开断相上产生很高的恢复电压,使得电弧不能自熄,导致断路器的重合失败.为此,如在相间并接电感Ll:(见图2),使得毗!:~1/(‘12),以形成并联谐振,阻塞了相间联系,非全相铁磁谐振就可被抑制.此时,图2中的零序电感大于正序电感,故实际上可通过在电抗器中性点上接入附加电感L、来达到目的。令L。为电,器本身的二序电感,则有LN。一L。+3LN,会 1 .3 1.-。~1..一=丫‘+资~;一,立二丫+3扩cl:,由此得LN二 LN。’L一2 Lo+3乙N·一一:‘,二~,一。1 F TXL,飞~了L于哥二万石一‘。」’‘。一3ClzCo十3C12ToL。三个单相电抗器组的L~L。,故LN~3(TK一To)。在拾电线路计划性合闸的第一阶段或计划性分闸┌───┬───┐│不孤妞│少《/ ││)乙” │ L.o │└───┴───┘图2并接相间电感后 的接线图的第二阶段,导线处于单侧供电下的空载状态,如断路器分相拒动或不同期动作,将会形成与上述相仿的谐振回路,附加电感L。可以同样起到消除谐振的作用。 当采用可控电抗器时,将其中性点不接地或者采取三角形接线方式,则当发生上述非全相运行状态时,快速调节三相电抗器的容t。使其相间感抗等于毗1:二1/(‘,:),谐振即可消除,井使潜供电流和恢复电压下降到容许数值以下。d}an}lx}tong telquonxlong yonx}ngg日od}onyo电j7系统非全相运行过电压(overvoltage inoPen phase operation in eleetrie power system) 电力系统在非全相运行条件下产生的铁磁谐振过电压。造成非全相运行的原因,是断路器的分相切合、分相拒动和三相触头间的不同期动作,以及高压熔断器的分相熔断和不对称分合操作等。 非全相运行过电压与断线谐振过电压的性质基本相同,区别在于非全相运行的断线点发生在断路器或熔断器处,非全相运行的谐振回路中不存在接地故障。 超高压长线路中普遍设置并联电杭器.其单相重合闸过程也是一种非全相运行方式,当单相(a相)开断和潜供电弧熄灭后,健全相通过对被开断相的相间的电容c,2而形成静电分盘的传递谐振回路,如图1所示。图中忽略了导线电感和电源漏抗,L为三相电抗器的正序电感,LN为电抗器中性点的附加电感,C。为导线的对地电容,U、和U。为健全相电压,电h丫二est峨,一一.图1单相开断后的传递谐振回路抗器的补偿度为TK~1/【扩L(c。+3CI:)〕。在LN~o时,谐振条件为毗~1/〔州C。+Zc:2)〕,或者TK二(C0+ZC12)/(C。+sC,2)。通常采取TK<1,故单
  
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条