1) HV electric energy measuring device
高压电能计量装置
1.
The problems in the aspects of design type selecting and wiring mode for HV electric energy measuring device were pointed out.
指出了当前高压电能计量装置在设计选型和接线方式方面存在的问题,针对在线运行高压电能计量装置设计选型和接线方式对其计量结果准确性和可靠性的影响进行了分析探讨,提出了改进建议,并对改进前后2种不同的高压电能计量装置设计选型和接线方式的实际电量进行了比对考核。
2) high voltage metering device
高压计量装置
1.
Based on that and the customers charge lists and mutual variable relation of the consumed energy and its power factor in the power sales system,the method of sifting and judging whether the high voltage metering devices to be abnormal,was proposed.
依据有、无功电能表的工作原理,提出在用户计费清单、电力营销系统中通过用电量和功率因数的联动变化关系来筛查、判断高压计量装置异常与否的方法。
3) power metering device
电能计量装置
1.
Design of remote on-line detecting system for power metering device;
电能计量装置远程在线检测系统的设计与实现
2.
This paper looks back the development course of power metering devices, and prospects the development tendency for the modern power metering devices in 21st century.
回顾了电能计量装置的发展历程,对21世纪现代电能计量装置的发展趋势进行了展望。
3.
Based on the analysis of the complex errors of power metering device, new factors that effect the metering accuracy in the system are proposed and the measures to decrease the errors are presented in this paper.
在分析电能计量装置的综合误差的基础上 ,提出了影响电能计费系统中电能计量精度的新因素 ,并提出了如何减少综合误差的方
4) electrical energy metering device
电能计量装置
1.
Analysis of three phase three wire electrical energy metering device common loop breaking and inverse wiring of current transformer secondary circuit;
三相三线电能计量装置公共回路断线及电流互感器二次反极性时接线分析
2.
The paper introduces the accuracy of gateway electrical energy meters,the secondary load evaluation of voltage transformers and current transformers,the error evaluation and secondary pressure drop of mutual-inductors for measurement in the electrical energy metering devices for gateway on Jiangsu power grid.
介绍了江苏省上网关口电能计量装置中关口电能表精确度、电压互感器及电流互感器二次负荷评估、计量用互感器误差评估以及二次压降评估,对装置中的电能表、计量用电压互感器、计量用电流互感器、计量回路的测试数据进行了技术统计与分析,给出了评估意见,针对存在的问题提出了合理化的建议。
3.
Based on the 2004 annual testing status,the present situation of electrical energy metering device for gateway on Jiangsu electric power grid is introduced.
根据2004年江苏省上网关口电能计量装置周检情况,介绍了江苏省上网关口电能计量装置的运行现状,分析了江苏省内关口电能计量装置目前存在的主要问题,并对上网关口电能计量装置的故障进行了统计。
5) energy measurement devices
电能计量装置
1.
Management information system ofgateway energy measurement devices based on JSP;
基于JSP的关口电能计量装置管理信息系统
2.
For designing a set of monitoring system for energy measurement devices,the following monitoring modules should be included:the errors of electrical energy meter,the accuracy of its clock,the secondary voltage drop of PT,the secondary load of CT and the harmonic.
一套电能计量装置监测系统,应包括如下模块:电能表误差监测、电能表时钟准确度监测、PT二次压降监测、CT二次负荷监测、谐波监测。
6) Electric energy metering device
电能计量装置
1.
The electric energy metering device improvement for large power consumer;
大用户电能计量装置改造初探
2.
Study on transformation means for electric energy metering devices in gas insulated switchgear;
GIS设备中电能计量装置改造方法的探讨
3.
The factors of affecting the accuracy of electric energy metering device and improving methods;
影响电能计量装置准确性的因素及其改进方法
补充资料:铁电体爆-电换能器
一种以铁电体作为换能器件的能量转换装置。铁电体器件在外加直流电场中进行极化时,其电畴取向趋向外电场方向。当外电场撤除后,电畴将保留一定的定向排列而形成剩余极化,同时,在电极被层上保留被剩余极化所束缚的电荷,这就意味着已有静电能贮存于铁电体内部。当爆炸形成的冲击波通过铁电体时,在冲击波的压力作用下,电畴被打乱、破坏或解体,剩余极化消失,电极被层上的束缚电荷变成自由电荷,这些电荷再通过负载向外输出电能。这就是铁电体爆-电换能器工作的物理过程。按照冲击波传播方向与剩余极化方向的相互关系,可以分为垂直、平行、斜交三种工作模式。
目前,垂直工作模式研究得比较多,其基本结构如图所示。铁电体器件通常采用被层为银电极的改性锆钛酸铅(简记作 PZT)系铁电陶瓷。这种换能器能够很方便地产生千安以上的短路电流和10万伏以上的开路电压,在电阻和电感负载相匹配的条件下,输出功率可达兆瓦级。这是一种一次性使用的高功率脉冲电能源,从1956年,F.W.尼尔森提出以来发展很快,现已在工业和军事上得到应用(它不同于热电换能装置,它的剩余极化的消失不是由于温度而是由于冲击波压力作用的结果;也不同于通常的压电换能装置)。
目前,垂直工作模式研究得比较多,其基本结构如图所示。铁电体器件通常采用被层为银电极的改性锆钛酸铅(简记作 PZT)系铁电陶瓷。这种换能器能够很方便地产生千安以上的短路电流和10万伏以上的开路电压,在电阻和电感负载相匹配的条件下,输出功率可达兆瓦级。这是一种一次性使用的高功率脉冲电能源,从1956年,F.W.尼尔森提出以来发展很快,现已在工业和军事上得到应用(它不同于热电换能装置,它的剩余极化的消失不是由于温度而是由于冲击波压力作用的结果;也不同于通常的压电换能装置)。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条