说明:双击或选中下面任意单词,将显示该词的音标、读音、翻译等;选中中文或多个词,将显示翻译。
您的位置:首页 -> 词典 -> 故障选线与定段
1)  Fault line selection and location
故障选线与定段
2)  fault selection and location
故障选线和定位
1.
With the improvement of automatic level in distribution systems,the single-phase-line- open fault selection and location is becoming the focus which is paid attention to and investigated.
随着配电网自动化水平的提高,单相断线故障选线和定位日渐成为人们关注和研究的焦点,对其故障特征的研究也日益紧迫。
3)  fault line selection
故障选线
1.
Method of distributed power system fault line selection based on transient high frequency instantaneous zero-sequence power;
基于暂态高频零序瞬时功率的配电网故障选线方法
2.
New approach for fault line selection in distribution system with arc suppressing coil grounding using decaying DC component;
一种利用衰减直流分量的谐振接地系统故障选线方法
3.
Research on fault line selection of single-phase grounding at two localities in power system with neutral unearthed;
小电流接地系统两点单相接地故障选线的研究
4)  fault line detection
故障选线
1.
Ant colony algorithm and neural network based fault line detection method for distribution network;
基于蚁群算法的神经网络配电网故障选线方法
2.
Project of fault line detection for single-phase-to-earth in distribution system;
配电网单相接地故障选线方案
3.
Study on fault line detection based on S-rough sets in indirectly grounding power system;
基于S-粗集的小电流接地故障选线研究
5)  faulty line detection
故障选线
1.
Artificial immune algorithm based faulty line detection method for indirectly grounding power system
基于人工免疫算法的小电流接地故障选线
2.
A faulty line detection method based on the high-frequency components of zero-sequence current is proposed.
应用在高频空间具有良好聚焦性的小波包工具,对故障后线路中的暂态零序电流进行分解,提取暂态零序电流在选定频带内的高频分量,以故障线与非故障线的零序电流高频分量之和的测度和故障线与非故障线的电流测度之和作为系统故障的特征信息,提出一种新的基于零序电流高频分量的故障选线判别方法;以自定义系统的故障特征值为主判据、故障电流高频分量为辅助判据实现故障类型的判断。
3.
A novel faulty line detection method based on wavelet packet analysis for distribution network is proposed to avoid improper detection caused by energy decay of zero sequence current signals at low sampling rate.
提出了基于小波包分析的配电网故障选线新方法用于解决低频采样零序电流信号因发生不同程度的能量衰减而导致的选线错误问题。
6)  faulty line selection
故障选线
1.
Aiming at the difficulty of faulty line selection for the single phase grounding of the network with neutral point earthed via controllable arc suppression coil,the ZSCR(Zero-Sequence-Current-Ratio) method is presented.
针对中性点经可控消弧线圈接地电网单相接地故障选线困难的情况,提出零序电流比幅接地选线新方法。
2.
The problem of the faulty line selection with the arc suppression coil(ASC) has existed for a long time.
故障选线问题一直困扰着消弧线圈接地系统。
3.
Limited,presents the method of faulty line selection based on negative sequence cur- rent component induced by small current grounding.
提出采用小电流接地负序电流故障分量法来进行故障选线,具有不受中性点电抗补偿的影响,且故障特征明显的优点。
补充资料:电气化铁路宝成线宝凤段


电气化铁路宝成线宝凤段
the Bao-Feng district of Bao-Cheng electric railway

d lonq.hL一ot旧ItJ Boo一Chengxlo犷、Boo一FengdUo门电气化铁路宝成线宝凤段(the Bao一Fengdistriet of Bao一Cheng eleetrie railway)中国电气化铁路宝成线北起西北重镇宝鸡市,南止四川省 省会成都市,沿途经过任家湾、秦岭、风 州、略阳、阳平关、广元、马角坝、绵 阳等车站,单线全长668km,是中国第 一条电气化铁路。其中的宝(鸡)风 (州)段是中国最早建成通车的电气化 区段(见图)。 宝凤段电气化铁路以中国铁路电 气化的先导和成功试点而载人史册。它 成为培养铁路电气化管理人才的摇篮, 为中国培养出一代又一代电力机车乘 务、牵引变电所和接触网管理、检修等 人才,先后向全国各电气化铁路输送了 大批技术干部和技术工人。 宝凤段线路主要技术条件线路 等级1级干线;正线数目:单线;限制 坡道30%。;最小曲线半径3oom;到发 线有效长度:650~700m;机车类型及 牵引方式:韶山1型电力机车,秦岭以 北为三机牵引,以南为单机牵引;牵引 定数2400t;闭塞方式:自动闭塞;隧 道净空高度为6328 mm。 牵引供电系统主要技术标准供 电制式:单相工频25kV;电力牵引供 电方式:电力牵引直接供电方式;接触 网悬挂方式:区间采用半补偿弹性链型 悬挂,站场采用简单链型悬挂。在宝鸡 设电力机务段、供电段和电力调度所各 一处,接触网工区则沿线分散设置。 主要工程数t全长glkm,建成 电气化铁路接触网141.3条·km,电 力牵引变电所3座,分别位于任家湾、 秦岭和凤州;敷设通信电缆81.84 km, 调度集中91km,电气集中信号站10 个,电力机务段和供电段各1处;铺设站线、岔线12 km,新建房屋2.57万mZ。该段1958年6月15日开1.1960年5月14日竣工,1961年8月15日正式投人运营。一叠,.叫桥梁~艘道卜~.叫坎路宝成线宝(鸡)凤(州)段线路示意图
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条