说明:双击或选中下面任意单词,将显示该词的音标、读音、翻译等;选中中文或多个词,将显示翻译。
您的位置:首页 -> 词典 -> 相分量
1)  Phase components
相分量
1.
It separates the network into symmetrical parts and unsymmetrical parts, synthetically uses sequence components and phase components.
针对高压电网中三相不对称线路的大量出现,传统的对称分量法及其序网连接失效的问题,提出了把电网分块成对称部分和不对称部分,综合应用序分量法和相分量法的改进的故障计算方法。
2.
This paper presents a new way, fault vector transformation method in phase coordinates, based on fault analysis of phase components.
该文以相分量故障处理方法为依据,提出了一种相分量坐标下的故障向量变换法:采用多态计算技术,用矩阵变换代替传统的数值计算,用不同的矩阵参数表达各种对称和不对称短路故障的特点,以使用统一的公式计算短路故障。
3.
Using phase components equation of element and analysis of conditions at the faults, a new method of fault calculation about open conductors condition is presented, which can be used in phase coordinates and symmetrical components coordinates by node admittance network equation and no bus need to be created.
以元件的相分量方程为依据 ,通过边界条件的分析 ,导出线路故障后的支路方程 ,代入节点网络方程中就可以直接计算各种故障。
2)  phase component
相分量
1.
The calculation for asymmetrical failures in electric power systems using phase components is studied with its applicability discussed.
研究了利用相分量计算电力系统不对称故障的方法,说明了该方法的实用价值。
2.
The calculation model used in this paper combined the advantages of sequence component and phase component.
故障计算模型采用相序结合的方法,对未受故障影响的网络部分采用序分量可以大大降低网络方程的阶数;对故障部分,使用相分量进行处理,可以直观的描述和处理任意复杂故障。
3)  vector analysis
相量分析
1.
It can be educed that the circuit of fluorescent tube is nonlinear electric device by vector analysis and wave shape observevation,so the vector analysis do not analyze this circuit,and could not validate KVL with vector analysis.
相量分析与波形观察表明,日光灯管为非线性器件,导致日光灯管端电压为非正弦波周期量,不能用相量分析法分析日光灯电路,即日光灯电路不能用相量法验证基尔霍夫电压定律。
2.
This article especially introduces how to use vector analysis method to analyze some common problems in secondary wiring in transformer differential-protection and secondary wiring.
本文着重介绍了如何利用相量分析的方法分析变压器差动保护二次接线的常见问题,以及如何通过试验判别变压器差动保护及二次回路接线的正确性,并简要分析了微机差动保护与传统的差动保护在二次接线与带负荷测试方法的异同之处。
4)  phasor analysis
相量分析
1.
By taking the modern mathematical set theory as the tool, this paper makes an exposition of the teaching method to improve the traditional lecture of phasor analysis in correspondence to the new changes of the students methematical elementary knowledge, and then makes an analysis and evaluation on the practical effect.
根据授课对象的数理基础所出现的新变化,阐述了以近代数学集合论为工具改进相量分析传统讲法的教学法要点,并对实践结果做了分析评估。
2.
To diagnose the fault of AC circuits including several dynamic components,a innovative method based on phasor analysis and support vector machines is presented.
针对工作在交流状态下的模拟电路,提出采用相量分析和支持向量机(SVM)相结合的方法,实现交流电路的故障诊断。
3.
Through phasor analysis of wiring category change in Y/△-11 transformer caused by different primary wiring,we can rapidly judge the fault according to differential protection phasor measured.
针对一起35kV变电站主变差动保护异常情况,通过对本变电站一次接线和二次回路检查及保护装置相应校验,对带负荷测相量的数据进行认真分析,确认变压器一次接线的变化是引起差动保护异常的根本原因,改变变压器一次接线并重新进行了带负荷测相量工作,确认相量无误后投入差动保护,主变微机型差动保护装置正常运行;并由此引出对各种一次接线引起Y/△-11变压器接线组别变化的相量分析,可以根据所测差动保护相量快速判断故障。
5)  phase-component method
相分量法
1.
The general models of the interface circuits for shunt and series faults and the impedance matrix of various 3-phase elements and parallel lines are constructed for the requirement of the simultaneous fault calculation for power system by using phase-component method.
为了对电力系统复杂故障直接进行求解,基于相分量法,建立了横向、纵向故障接口电路的通用相分量模型,推导了三相元件与平行线路的相分量阻抗矩阵。
2.
A calculation approach using integrated symmetry-component and phase-component methods is presented in this paper in order to meet the requirements of the calculation of inter-line faults, which occur on parallel transmission lines of large scale power systems.
针对电力系统中平行线路的跨线故障,提出一种融合对称分量法与相分量法的大规模电力系统跨线故障计算方法。
6)  Individual phase measurement
分相测量
补充资料:对称分量
      由不对称三相相量分解而得的对称三相相量。一组不对称三相相量凔、妋、凗,当三者之和不为零(即凔+妋+凗≠0)时,可以分解成三组对称三相相量,它们分别是:零序分量,记为凔0,妋0,凗0;正序分量,记为凔1,妋1,凗1;负序分量,记为凔2,妋2,凗2。由于三相电力系统中有三相交流电机、三相输电线等三相电路元件,它们的电路参数在对称的运行条件下较便于确定,因而将非对称三相相量分解为三组对称分量便可分别考虑在每一相序的电压、电流作用下三相电路的工作情况,然后根据叠加定理得到三相电路的工作情况。
  
  零序分量如图1所示,其特征是3个相量大小相等且同相。妋0=凔00=凔0正序分量如图2所示,其特征是3个相量大小相等但不同相。三者按妋1滞后凔1,凗1滞后妋1,凔1又滞后凗1的顺序互差120°,即
  妋1=a211=a凔1
  式中
  
   
  负序分量如图3所示,其特征类似正序分量,也是3个相量大小相等但不同相。不过,此时3个相量是按凗2滞后凔2,妋2滞后凗2,凔2又滞后妋2的顺序互差120°,即妋2=a凔22=a22三组对称分量与原不对称三相相量的关系如下:不对称三相相最可以是三相电压相量,也可以是三相电流相量。在三相不对称电路中,有的不对称电压相量和不对称电流相量只有两组对称分量。例如,不对称线电压相量,因必须满足KVL,即妭AB+妭BC+凗CA=0,故只含有正序对称分量和负序对称分量。
  
  

说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条