1) self-shattering
零值自爆
1.
At the beginning of 2006,the insulators on 220 kV transmission lines in Zhengzhou area suffered a failure of self-shattering of insulator with zero resistance leading to line conductor drop down to ground.
分析了2006年年初郑州供电区域220kV线路零值自爆掉串导致导线落地事故,结合实际测量的数据和试验室数据,讨论了近年来高压输电线路上悬式绝缘子串检测零值绝缘子的各种方法:短路叉法、火花间隙法、小球放电法、红外热像仪法、绝缘电阻法、激光多谱勒振动法、电压分布法、紫外成像法和智能绝缘子检测仪法,并比较了各种方法的优缺点。
2) the zero value
零值
1.
In our paper for the kind of question of the zero value of the expected input signal of controlling object,utilized the relation between feedback transfer function and the input signal,proposed a new controlling strategy,and analysed the relation between which and the tradition PID controller.
针对控制对象中输入信号(期望值)为零值的一类问题,利用反馈传递函数与输入信号之间的关系,提出了一种新的PID控制策略,并分析了与传统PID控制方法之间的关系。
3) zero line
零值线
1.
The shape and character of the zero line,an important criterion for magnetic memory testing of the normal field is analyzed under different longitudinal magnetization.
根据磁偶极子空间磁场分布,导出了地磁场下管状工件表面细长缺陷段产生的弱磁场法向分量的计算公式,并且分析了不同纵向磁化强度下,作为磁记忆检测方法重要判据的磁场法向零值线形状及分布特点。
4) zero value method
零值法
5) zero drift
零值漂移
1.
In this paper, through working on C/O ratio to get rid of zero drift, and limit the C/O radio to the generalized performance range, and use universal interpretation model to deal with data of C/O ratio.
利用碳氧比规范化处理,将碳氧比值限制在广义动态范围之内解决零值漂移问题,使用通用解释模型处理碳氧比资料。
6) faulty insulator detection
零值检测
参考词条