说明:双击或选中下面任意单词,将显示该词的音标、读音、翻译等;选中中文或多个词,将显示翻译。
您的位置:首页 -> 词典 -> 500kV紧凑型线路
1)  500 kV compact transmission line
500kV紧凑型线路
2)  the 500 kV compact transmission line
500kV紧凑型输电线路
3)  compact transmission line
紧凑型线路
1.
Since the multi-split conductors are adopted in domestic compact transmission line of single circuit, the selection of line (phase) spacing in span centrality becomes the one of key problem of deciding the technical parameters of compact transmission line.
目前国内采用的单回路紧凑型线路相导线分裂根数多,线(相)间距离小,因而档距中央线(相)间距离的选取就成为决定紧凑型线路技术参数的关键问题之一。
2.
The parameters of 500kV Changping—Fangshan compact transmission line are calculated and compared with that of conventional transmission lines.
采用EMTP程序计算了昌平—房山500kV 紧凑型线路参数及其运行特性。
4)  Compact line
紧凑型线路
1.
Nonlinear motion analysis on 500kV compact line conductor;
500kV紧凑型线路导线非线性运动分析
2.
kV ShenmuXinzhouShibei Lines are adopted twocircuit compact lines.
针对神木-忻州-石北采用双回紧凑型线路,计算了其操作过电压,并且用线路闪络率作为判据对是否装合闸电阻进行了详细分析。
3.
Based on the electrical theory,this paper introduces the principle of improving the transmission capacity with the compact line of large surge-impedance loading power.
紧凑型线路是当前输电线路发展的一个新趋势。
5)  compacted circuit
紧凑型线路
1.
Equations on forced vibration in compactedcompacted circuit systems with displacements as unknown functions are formed, and the analytical formulae for calculating the dynamic of the spacers are obtained by solving the equations.
以两相导线、一个间隔棒组成的一个档距的紧凑型线路系统为研究对象 ,推导了系统以位移为未知函数的强迫振动方程 ,及相间绝缘间隔棒动力计算的解析公式 ;用模拟线路段参数计算了线路系统发生两相接地短路故障时 ,间隔棒承受的动
2.
This paper deduces the free vibration equations of the line system of compacted circuit wth the displacements as the unknown functions, and thus by solving the equations obtains the analytical formulaes for calculating the natural frequencies and vibration models of the line system of compacted circuit.
推导了紧凑型线路导线系统以位移为未知函数的自由振动方程。
6)  compact transmission line
紧凑型输电线路
1.
As the parameter characteristics of compact transmission lines are quite different from those of conventional transmission lines, a study of their influence on sub-synchronous resonance (SSR), the advantages and disadvantages of some series-compensated compact transmission lines for the heat-engine plant is of practical significance.
紧凑型输电线路的电气参数与常规输电线路存在较大差异,因此分析其参数特性对次同步谐振(SSR)问题的影响,探讨应用串联补偿的紧凑型输电线路进行火电厂送出在SSR问题方面的利弊具有实际意义。
2.
This paper introduces the technical characteristics of compact transmission lines and their applications at home and abroad,emphatically analyzing the main technical features,project costs and operation of 500 kV compact transmission line from Luoping to Baise located at high altitudes of southern power grid of China.
介绍了紧凑型线路的技术特点及国内外应用情况,特别对位于南方电网高海拔地区的500 kV罗平—百色紧凑型输电线路主要技术特点、工程造价、运行情况进行了分析。
3.
Two dimensional FEM is applied to the research on the power frequency electric field around compact transmission lines,and the method to improve the precision of calculation is discussed.
基于二维有限元法研究紧凑型输电线路分裂导线周围工频电场并探讨提高计算精度的方法,计算对比了500 kV紧凑型线路导线表面最大平均电场强度和线路下方距地面1 m处的最大电场强度和走廊宽度,考虑了几种子导线异型排列方式。
补充资料:安定500kV变电所


安定500kV变电所
Anding 500kV substation

器。220 kV策电装1采用剪刀式母线陈离开关配支持式铝管母线分相布t方案。支持式铝管母线系统由高强度的220 kV支柱绝像子和单根铝管母线及特殊连接金具组成,铝合金管母线外径扒30 mm,内径帆20mm,壁厚5 mm,相间距离3m,对地高度8.42m,跨度13m,每隔3跨铝管母线设1个伸缩节。220 kV配电装里间隔宽度仅为13m,纵向长度60m(主变压器22okV进线门型构架中心线至220 kV出线电容式电压互感器中心线之间的距离),占地面积15600m,。 户外同步调相机本变电所安装1台苏联进口KcB任1 60一1 syl型茸天布t的同步调相机,额定电压15.75 kV,颊定物出无功功率160 Mvar,欠励磁运行时吸收额定无功功率80 Mvar。并从苏联成套进口了启动电抗器、空气断路器、隔离开关、电压互感器及电流互感器、进贡器以及程序启动屏、励磁调节屏等电气设备。 同步调相机按苏联的典型接线进行设计、施工安装.调相机接在500 kV主变压器低压侧第三绕组15.75 kV母线上,采用电扰器降压启动的方式,启动时间约405。在同步调相机主工作回路和启动电抗器回路均安装1250oA大电流空气断路器,额定开断电流160 kA.同步调相机本体为带无刷励磁系统的氢冷三相同步调相机,低转速750r/min。利用二次循环水冷却氮气和润滑油。同步调相机本体耳天布t在1.16m高的运转平台上,同步调相机基座的下面地下一4.om设框架结构地坑,冷却同步调相机转子和定子的氢冷却系统安装在此地坑内。在相邻地下一3.om地坑内安装润滑油冷却系统和备用油箱。除了主机礴天布t在地面上以外,同步调相机的氢冷却系统、润滑油系统、压缩空气系统等均布t在地下.苏联尽天同步调相机具有单机容t大、厂房结构简单、布t十分紧凑等优点。Anding 500 kVb旧nd一ansuo安定500 kV变电所(Anding 500 kV sub-station)北京新建的500 kV大型枢纽变电所,位于北京东南郊大兴县内,是连接北京、天津、唐山500 kV电力系统的枢纽,建设规模大、出线回路数多,地位十分重要。1992年n月开始建设,1994年9月正式投入运行。 建设规模安定500 kV变电所包括500 kV、220 kV、3 5 kV和15.75 kV四级电压。500 kV和220 kV为变电所与外部电力系统连接的电压等级。35 kV和15.75kV电压等级均无出线,第一期工程安装l台160 MV·A同步调相机,采用15.75 kV电压等级。将来发展采用电容器组和电杭器组无功补偿装t,则采用35kV电压等级。 500 kV出线最终10回,第一期5回。220 kV出线最终10回,第一期7回。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。