说明:双击或选中下面任意单词,将显示该词的音标、读音、翻译等;选中中文或多个词,将显示翻译。
您的位置:首页 -> 词典 -> 农村电网谐波
1)  electrical harmonic of rural power network
农村电网谐波
2)  rural power grids
农村电网
1.
In view of the problems arose from the line loss management of the rural power grids,the paper discussed the loss reduction measures and the principles to be followed from the technical and management aspects.
针对农村电网线损管理中存在的问题,从技术和管理两个方面提出具有实践意义的降损实施要点和原则。
2.
This paper describes the technology and transferring of rural power grids information network,analyses technology of communications network system of electric power grid in rural area,chooses a new develop direction of technique based on the business needs and trend of rural power grids,gives a route for development.
对农村电网信息业务和传输方式进行了描述,分析了农村电力专用通信网络现有的信息技术体制,并基于农村电网的业务需求和发展趋势,选择一种适合的新技术体制作为发展方向,在此基础上给出信息基础网络的发展思路。
3)  rural power network
农村电网
1.
Research on Construction Cost Evaluation Index of Rural Power Network Transmission and Transforming Project in Bayannaoer;
巴彦淖尔地区农村电网输变电项目工程造价评价指标研究
2.
Aiming at the high rate of theft and destruction of electric power facilities at present,a new type of power outage alarm for rural power network has been developed upon analysis of the working principle and defects of the old-style multifunctional power outage alarm.
针对当前盗窃、破坏电力设施的案件居高不下的情况,在分析了旧式多功能断电报警器的工作原理和缺陷的基础上,研制了新型的农村电网断电报警装置。
3.
The realization of dispatching automation system of rural power network is the key to ensuring operation stability of rural power network.
VSAT卫星通信组网比较适合于农村电网的现状。
4)  rural power grid
农村电网
1.
Application of optical fiber differential protection in rural power grid
农村电网中光纤纵差保护的应用
2.
With consideration of the shortage that the tradition discriminant method of overhead lines of rural power grid is complex and hard to programme, a discriminant algorithm of control climate condition of rural power grid based on iterative technology is introduced.
针对农村电网架空线路控制气象条件的传统判断算法繁琐,不适合计算机处理的问题,提出了基于迭代技术的农村电网架空线路控制气象条件的判定算法。
5)  rural network
农村电网
1.
Comprehensive evaluation of construction and retrofit projects for rural network of Anguo city;
安国市农村电网建设与改造项目综合评价
2.
Study on Rural Network Evaluating Method;
农村电网结构评价方法的研究
3.
Based on the loss reduction and energy conservation requirements,the key points and methods for reducing the energy loss in rural network are discussed combining the practical operation situation of rural network after the net reconstruction.
围绕降损节能的工作要求,结合农网改造结束后电网的实际情况,对降低农村电网电能损耗的关键环节和方法进行了探讨,并提出了降损节能的措施。
6)  rural electric network
农村电网
1.
Aims to analyses the current pollution problems of power system in our country,and to investigate the main reasons which caused pollution in rural electric network.
针对目前我国农村地区电网谐波污染日趋严重现状,系统分析了造成农村电网谐波污染的主要原因,详细探讨了谐波污染在电能计量、继电保护、线路损耗等方面造成的危害。
2.
The guideline for the layout and reconstruction of rural elcectric network can be obtained throngh evaluating the performance of rural electric network.
对农村电网性能进行系统、科学、客观的评价,可以有效地指导农村电网的建设与改造,评价指标体系是电网性能评价的基础。
3.
This paper introduces a design scheme of the rural electric network s remote monitoring system, expounds its system structure and general functions, and emphatically describes the design of the embedded network server and the communication software of this system, and introduces the data collecting technique and the real-time network communicating technique involved in this system.
介绍了农村电网远程监测系统的设计方案,阐述了其系统结构及总体功能,重点介绍了用于该系统的嵌入式网络服务器的设计及通信软件的设计以及该系统所涉及的数据采集技术、实时网络通信技术等。
补充资料:谐波对电网的危害

谐波的危害电力系统中谐波的危害是多方面的,概括起来有以下几个方面:


    1. 对供配电线路的危害


    (1) 影响线路的稳定运行


    供配电系统中的电力线路与电力变压器一般采用电磁式继电器、感应式继电器或晶体管继电器予以检测保护,使得在故障情况下保证线路与设备的安全。但由于电磁式继电器与感应式继电器对10%以下含量高达40%时又导致继电保护误动作,因而在谐波影响下不能全面有效地起到保护作用。晶体管继电器虽然具有许多优点,但由于采用了整流取样电路,容易受谐波影响,产生误动或拒动。这样,谐波将严重威胁供配电系统的稳定与安全运行。


    (2) 影响电网的质量


    电力系统中的谐波能使电网的电压与电流波形发生畸变。如民用配电系统中的中性线,由于荧光灯、调光灯、计算机等负载,会产生大量的奇次谐波,其中3次谐波的含量较多,可达40%;三相配电线路中,相线上的3的整数倍谐波在中性线上会叠加,使中性线的电流值可能超过相线上的电流。另外,相同频率的谐波电压与谐波电流要产生同次谐波的有功功率与无功功率,从而降低电网电压,浪费电网的容量。 


    2. 对电力设备的危害


    对电力电容器的危害


    当电网存在谐波时,投入电容器后其端电压增大,通过电容器的电流增加得更大,使电容器损耗功率增加。对于膜纸复合介质电容器,虽然允许有谐波时的损耗功率为无谐波时损耗功率的1.38倍;对于全膜电容器允许有谐波时的损耗功率为无谐波时的1.43倍,但如果谐波含量较高,超出电容器允许条件,就会使电容器过电流和过负荷,损耗功率超过上述值,使电容器异常发热,在电场和温度的作用下绝缘介质会加速老化。尤其是电容器投入在电压已经畸变的电网中时,还可能使电网的谐波加剧,即产生谐波扩大现象。另外,谐波的存在往往使电压呈现尖顶波形,尖顶电压波易在介质中诱发局部放电,且由于电压变化率大,局部放电强度大,对绝缘介质更能起到加速老化的作用,从而缩短电容器的使用寿命。一般来说,电压每升高10%,电容器的寿命就要缩短1/2左右。再者,在谐波严重的情况下,还会使电容器鼓肚、击穿或爆炸。


    对电力变压器的危害


    谐波使变压器的铜耗增大,其中包括电阻损耗、导体中的涡流损耗与导体外部因漏磁通引起的杂散损耗都要增加。谐波还使变压器的铁耗增大,这主要表现在铁心中的磁滞损耗增加,谐波使电压的波形变得越差,则磁滞损耗越大。同时由于以上两方面的损耗增加,因此要减少变压器的实际使用容量,或者说在选择变压器额定容量时需要考虑留出电网中的谐波含量。除此之外,谐波还导致变压器噪声增大,变压器的振动噪声主要是由于铁心的磁致伸缩引起的,随着谐波次数的增加,振动频率在1KHZ左右的成分使混杂噪声增加,有时还发出金属声。


说明:补充资料仅用于学习参考,请勿用于其它任何用途。