1) auxiliary power
厂用电
1.
Optimizing wiring mode of auxiliary power supply;
厂用电源接线方式的优化
2.
In accordance with the basis of comparison of different shift for 6kV auxiliary power in power plants,especially on the profound analysis of structure about Vacuum Circuit Breaker,it is concluded that there should be different shift methods of auxiliary power,due to characteristics of auto quick shift and problem of synchronism,and the different shift will be done for the different circumstances.
对发电厂6 kV厂用电的各类切换方式进行了比较,针对真空断路器的结构,厂用电的切换方式、自动快速切换的特点以及同期问题进行了深入的分析,强调了对应不同的实际情况应采取不同的切换动作。
3.
This paper analyzes the reason of auxiliary power outage resulted from incorrect actuation of transformer differential protec- tion.
分析了变压器差动保护误动引起电站厂用电全停的原因,认为在采用新型数字式差动保护继电器情况下要特别注意被保护变压器的组别。
2) station-service power
厂用电
1.
Design of station-service power of the ZHS;
昭平水电站的厂用电设计
2.
,Ltd,put forward optimized method of circulating water system operation mode,compared and analyzed the features under different operation mode in order to decrease station-service power ratio and promote unit s efficiency.
阐述了七台河发电厂350 MW汽轮机组循环水系统的运行方式,提出了循环水系统运行方式的优化方法,比较分析不同优化运行方式的特点,以降低厂用电率,提高机组经济性。
3.
This paper introduces the reformation of the station-service power supply equipment at Chencun Hydropower Station.
介绍了陈村水电站厂用电系统设备技术改造情况。
3) service power
厂用电
1.
The article introduces the connection type of the unit auxiliary power system of 2× 350 Units in Jiujiang power plant phase Ⅲ project, and the requirements and the basic principles to be followed for DCS to control the electric system; describes the utilization of DCS in the unit service power system based on the actual logic and analyze the problems occurred in the operation of the system.
介绍九江电厂三期2×350MW机组厂用电系统结线方式和特点,以及DCS对电气系统控制的要求及遵循的基本原则;结合实际逻辑阐述DCS系统在厂用电系统中的运用;针对该系统运行中出现的问题进行了归类和分析。
2.
All automatic switching in devices of service power sources used in the domestic power plants in the past were of low speed switching-over.
国内以往发电厂的厂用电源自动投入装置都为慢速切换。
3.
Owing to the development of power systems,the structure of the service power system in many large hydropower plants is complex,and the cooperation of relay protection becomes more and more important.
大型水力发电厂厂用电系统结构复杂,厂用电保护的配合问题日渐突出。
4) station service power
厂用电
1.
A detailed introduction is made on some characteristics of the station service power of Baise Multipurpose Dam Project,including the connecting mode of station service power supply,selection and characteristics of voltage level,wiring schemes,selection and characteristics of main electrical equipment etc.
介绍百色水利枢纽厂用电设计的一些特点,对厂用电源的引接方式、电压等级的选择、接线方案、主要电气设备选择及其特点作了详细介绍。
2.
In order to ensure safe and reliable operation of station service power system of Xiaolangdi Hydropower Station, the reliability on system structure, protection, design and standby power source automatic put-in device, etc.
为保证小浪底水电厂厂用电系统的安全可靠运行,对其系统结构、保护配置、备用电源自投自复装置等可靠性进行了分析,并针对电厂运行中出现的故障及采取的改进措施进行了总结,为机组的安全运行提出了许多可行的建议。
5) station service
厂用电
1.
Application and research of station service fast switchover;
厂用电快速切换应用与研究
2.
The technical plan of station service connecting about Shendong Thermal-Power plant is equipped for the great project of MeiYe Hua is presented.
提出了神东电力公司大型煤液化工程项目所配套的热电厂厂用电接线技术方案。
3.
On the base of selection for ranks of power supply voltage, technical and economical comparison was underway on type selection on many-side from connection ways, auxiliary transformer, electric motors switching-on and switch cabinets to 3 schemes of power supply, and station service of 600 MW air-cooled generator units in Tongliao power plant was the example.
在介绍供电电压等级选择的基本原则基础上,以通辽发电厂600MW亚临界空冷发电机组的厂用电为例,对3种供电方案,从接线方式、厂用变压器、电动机启动、开关柜、电缆等多方面在选型上进行了技术经济对比,最后,推荐600MW亚临界空冷发电机组高压厂用电采用10/6/0。
6) domestic load
厂用负荷,厂用电
补充资料:厂用电电源
厂用电电源
station service power supply
引接厂用电电源(变压器)。将水电站施工使用的变电所和线路按永久性建设,引接厂用电电源(变压器).同时还可兼作水电站所在地的近区用电.也是比较经济、方便的方式。这是目前水电站常用的外来厂川电电源取得的方式。 (4)由开关站的高压母线引接厂川电电源变压器.电源可靠,不受机组停止运行的影响。但需配置高压电源变压器及相应高压开关设备,因此.一般只考虑在220 kV及以下电压级高压母线上引接。 (5)梯级水电站或水电站群,当其地理位置相近,它们之间有6一35 kV的供电联络线时,利用其联络线引接厂用电电源变压器,也是很合适的选择。 (6)装设快速起动的柴油发电机组,是大型抽水蓄能电站和调峰频繁的水电站厂用电备川电源的一种方式。虽然可靠性高,但投资大、维护l_作址大、年运行费高,通常只作为电站机组不能黑起动而又有水淹厂房可能的电站以及对防洪泄洪有较高要求的水利枢纽闸门和启闭机设备等的应急电源。 (7)单独装设厂用小型水轮发电机组作为厂川电电源,供电可靠.但价格昂贵.维护l_作址大,年运行费高,现在很少采用。ehorlgyor1Qd一门11d一。rlyt一‘」rl厂用电电源(station Serviee power supply) 向水电站水轮发电机组和主变压器的附属设备、全厂生产辅助设备、厂坝区公用设施以及暖通和照明负荷供电的电源。 厂用电电源的要求厂用电的电源应满足电站各种不同运行工况下,在数量、电压、容量等方面能满足厂用电负荷供电可靠的要求。①厂用电源的数量,通常根据电站规模及运行方式确定。对中型水电站要有2个及以上的独立电源;对调峰电站,其中1个应是外来电源或能自动切换为由外来电源供电;在全厂停机时,可允许仅有1个厂用电电源运行。大型水电站要有3个及以上的独立电源,其中至少有l个是外来电源;在任何运行方式下,应保持2个厂用电电源运行。外来电源的作用是在全厂停机时,保证对重要的厂用电负荷供电。儿个独立电源可以同时投入供电,互为备用。也可采用工作电源运行,备用电源不投人运行,当工作电源故障时,备用电源自动投入运行的工作方式。②厂用电源的电压。当厂用电设备负荷相对较集中,全厂厂用电负荷不大,且无高压电动机负荷时,如中型水电站,一般采用低压0.4 kV一级电压供电,可减少变压器重复容量、损耗以及厂用配电装置数量,有利于厂房布置。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条