3) differential transformer
差动变压器
1.
Application and analysis of a differential transformer;
一种差动变压器的应用与分析
2.
Design and Optimization of Three-section Differential Transformer Used as Displacement Sensor;
3段式差动变压器位移传感器的设计及优化
3.
On the factors influencing sensitivity of the transducer of differential transformer;
影响直线式差动变压器灵敏度因素的研究
4) LVDT
差动变压器
1.
The traditional sensor based on LVDT is applied widely because of its fine performances such as simple structure, high sensitivity, fine linearity and wide measuring rang, etc.
差动变压器式位移传感器因其具有结构简单、灵敏度高、线性度好和测量范围宽等优点在工业中被广泛应用,但普通的传感器只适用于常温常压。
2.
As for the dynamic performance, the Linear Variable Differential Transformer (LVDT) displacement sensor using signal conditioner AD598 is not so good, so the differential rectifier is designed as the measuring circuit of the sensor so as to increase its cross-over frequency.
本文对一种新型的差动变压器式径向位移传感器在磁悬浮轴承中的应用进行了研究。
3.
In this paper, the self-sensing magnetic damper is presented based on LVDT(linear variable differential transformer).
本文根据差动变压器原理研制了自感式电磁阻尼器,该结构结合电磁轴承和差动变压器工作原理的优点,一方面可实现电磁阻尼器的非接触式稳定悬浮,另一方面为降低电磁阻尼器的成本提供了条件。
5) transformer differential protection
变压器差动保护
1.
Study of transformer differential protection based on the CT-saturation-integrate-method;
基于CT饱和综合判据的变压器差动保护的研究
2.
Analysis and countermeasure of transformer differential protection malfunction due to CT saturation;
CT饱和引起变压器差动保护误动的分析与对策
3.
Ethernet data interfaces for transformer differential protections based on filtering-interpolation-extraction method;
基于滤波插值抽取方法的变压器差动保护以太网数据接口
6) transformer differential relay
变压器差动保护
1.
At first,this paper analyzes the difficulties on hardware and software during the digital realization of transformer differential relay based on dead angle philosophy,and provides the methods to overcome them.
从硬件和软件两方面,对间断角原理变压器差动保护微机化实现过程中遇到的困难进行分析并给出解决方法。
补充资料:变压器差动保护系统调试
变压器差动保护系统调试
commissioning of the differ- ential protection system for transformer
b ianyaqi chadong baohu xitong tiaoshi变压器睡动保护系统调试(eommissioningof the differential Proteetion system for trans-former)对流入变压器和自变压器流出的两侧电流,经电流互感器检测变换之后进行比较,其电流差值反映出变压器的内部故障情况.根据这一原理,由电流互感器、差动继电器、断路器跳闸机构组成的保护系统称为变压器差动保护系统.当电流互感器的变比和结线方式与被保护的变压器相适应时,变压器正常运行电流及变压器以外的穿越性故障电流不会使差动保护动作.空载变压器接入电源时,电源侧向变压器流入较大的励磁涌流,为减少它对保护系统的影响,消除误动作,变压器差动保护系统中设有速饱和变流器或谐波制动电路。变压器差动保护系统的调试分差动保护继电器的单体调试和差动保护系统模拟试验两个步骤. 差动保护继电器的单体调试变压器差动保护继电器依其结构特点可分为机电型、整流型、静态型等。机电型差动保护继电器由速饱和变流器、电磁动作的执行继电器、换档擂接板等组成,其调试项目主要有:(1)外观检查,插接与机械动作部分的检查和调整。(2)电磁式执行继电器的常规调试。(3)速饱和变流器的特性试验:检查各绕组极性与结线的正确性;测定变流器伏安特性曲线;通入试验电流,测定执行继电器动作时各绕组分档的动作电流安匝数,并将其整定到设计规定的范围内;测定直流助磁特性,即测定相对动作电流。=(‘/i。)和偏移系数K(1/1)间的函数关系。式中,I为速饱和变流器一次侧通入的直流试验电流(A)八为通入直流分量I时速饱和变流器一次侧的交流动作电流(A);i。为未通直流分量时的交流动作电流(A)。(4)在整定位置下测定保护继电器的整组伏安特性,即差动继电器输入差动电流信号安匝数与执行继电器线圈端电压之间的关系,以判别差动继电器工作磁通密度选取是否合适。 整流型差动保护继电器由差动元件和瞬动元件两部分组成。差动元件包括工作回路、比率制动回路、谐波制动回路及直流比较回路。调试项目主要有:(l)工作回路最小动作电流与返回电流的测定,动作电流整定。(2)比率制动回路动作特性试验。给工作回路和制动回路同时通入试验电流,测定继电器产生输出动作时两试验电流数,绘制出它们的函数关系曲线(即比率动作特性曲线),按照保护设计要求对比率动作特性进行整定。在无特殊要求时,两试验电流取同相位电流。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条