1) injected zero-sequence voltage
零序电压注入
1.
This paper analyzes the neutral-point balancing problem of three-level Neutral Point Clamping(NPC) inverter,and discusses the injected zero-sequence voltage PWM method for neutral-point balancing control.
分析了三电平中点箝位(Neutral Point Clamping,简称NPC)逆变器的中点电位平衡问题,讨论了通过注入零序电压实现中点电位控制的载波PWM方法,并在此基础上对一种实时控制中点电位平衡的方法进行了改进,提出一种基于零序电压注入的载波交叠PWM方法。
2) zero sequence voltage
零序电压
1.
The relation involves modulation signal and space vector,zero sequence voltage and redundancy vector and so on.
全面分析了三电平逆变器中应用的空间矢量调制法与载波调制法这两类调制方法的内在联系,包括调制信号与空间矢量、零序电压与冗余矢量的分配因子。
2.
Based on the analysis of the characteristics of open phase operational state, a novel open phase protection scheme utilizing the zero sequence voltage of the terminal and the negative sequ.
在分析非全相运行状态特点的基础上,提出了一种基于Powerformer机端零序电压和定子绕组负序电流的非全相运行保护方案。
3.
From analyzing the shape of the wave of the zero sequence current and zero sequence voltage,we acquire which phase fails.
MATLAB是对系统进行仿真,通过零序电流和零序电压的波形对系统进行分析,从而得到哪相发生故障。
3) zero-sequence voltage
零序电压
1.
Improvement of the zero-sequence voltage sampling circuit in coal mine high-voltage distribution device;
煤矿6(10)kV高压配电装置零序电压取样电路的改进
2.
Analysis of zero-sequence voltage protection
零序电压保护的改进方法分析
3.
In order to solve the problem ot single phase grounding fault locating in non-effectively grounding networks, a zero-sequence voltage based practical method of locating and isolating for single phase grounding fault section is proposed in this paper, which operates on the feeder automation system of voltage-time type.
为解决小电流接地系统单相接地故障定位困难的问题,介绍了一种在电压时间型馈线自动化系统中基于零序电压检测的馈线单相接地故障区段定位与隔离方法,阐述了该方法的工作原理和馈线终端单元(FTU)的运行方式。
4) zero order voltage
零序电压
1.
The zero order voltage output from inverter will form common mode voltage, which drives the common mode current through the parasitic circuit loop in motors.
基于该规律,提出了一种将级联型多电平逆变器输出零序电压幅值的相对值限制为1/3的空间矢量调制算法。
5) injecting voltage
注入电压
1.
After drawing the injecting voltage-average peak energy scattering dots curves,the scattering dots have been imitated together by adopting curve imitation method.
利用静电放电(ESD)模拟器对集成电路芯片进行电压注入损伤效应实验,通过存贮示波器记录的波形进行乘法和积分运算,得到对应注入电压下芯片上吸收的平均峰值功率和能量。
6) voltage reinjection
电压注入
1.
The multi-level voltage reinjection concept makes it possible for a converter to provide acceptable harmonic reduction with fewer switching components than the conventional multi-level schemes.
与传统的多级方案相比多级电压注入的优点在于它使用相对较少的开关元件达到消除谐波的目的。
补充资料:交流电气化铁路的负序电流和负序电压
交流电气化铁路的负序电流和负序电压
the negative sequence current and voltage produced by AC elec-tric railway
处为最大,随着负序电流逐渐分散进人电力系统,系统各处的负序电压水平将逐渐下降。YN,d一l:v.v:单相平衡接线11:重臂负荷I]l=轻价负荷月=111/11两,负荷功率因教相同0。250。5751。0 图2不同接线牵引变电所的负序电流系数 允许标准不同类型发电机的负序承受能力不同,为此,首先应根据有关电机制造标准,选择允许的负序标准。在缺少电机制造标准规定时,可参照以下规定:当汽轮发电机在额定工况连续运行时,三相电流差不应超过10%,水轮发电机三相电流差不应超过20%;有关电力系统公共连接点的三相电压不平衡度,中国国家标准规定:“正常的电压不平衡度允许值为2%,短时不得超过4%”。 改善措施主要有: (1)对电气化铁路各牵引变电所实行进线相序轮换,减少电气化区段的综合负序。 (2)采用平衡接线变压器,常用的接线型式有斯科特、列布兰、变形伍德布里奇等方式。 (3)在受负序电流影响最大的电力系统分支回路中加装电抗器,以限制进人该支路的负序电流。i旧01一u dlanqihua tielu de fuxud一anl旧he fuxud一onya交流电气化铁路的负序电流和负序电压(thenegative Sequenee eurrent and voltage produeedby AC eleetrie railway)交流电气化铁路的单相牵引负荷会造成电力牵引变电所一次侧三相负荷电流不平衡,任一三相不平衡系统均可用对称分量法分解成正序、负序和零序三组对称分t的盈加,从而在电力系统中产生负序电流和负序电压.接人电力系统线电压间的单相负荷不产生零序分量,只有正序和负序分t。负序电流、负序电压的有害影响有: (l)可在同步发电机转子中产生附加损耗和局部发热,造成系统出力下降, (2)负序电流产生的负序转矩,使发电机振动,影响安全运行; (3)增大系统中各翰电环节的损耗; (4)负序电压的存在对系统中三相电动机用户产生不利影响,造成电动机三相电流不对称和附加损耗,使出力下降并危及电动机安全。 牵引变电所的负序电流电力牵引变电所负序电流取决于两供电臂负荷的相位和幅值,因此可以把牵引变电所看作是一个负序电流源. 图1示出变压器为YN,dll接线的三相牵引变电所在两份用电功率因数相同时的负序电流相盆图.图1的上方为臂电流和变压器二次绕组的三相电流相量;中间为正序电流相量;下方为负序电流相t.不同供电臂产生的负序电流有1200相位差。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条